21
8.
Set
PIC8-1
(16)
Vacuum detection:
if you turn off vacuum detection, machine will not detection of
pick failure, and also not throwing materials.
(1)
Visual assist:
close it will have no vision function
(2)
Visual lack detect:
if you turn on this function, system will pick again when it
detects lack of materials. If detect many lack of material many times, machine will
alarm and stop working.
(3)
Z Axis detect:
if you turn on this function, if Z axis lose step when mounting, Z
axis will back to origin automatically. Turn on this function will help to prevent Z
axis due to incorrect setting of component height.
(4)
Auto Calib. PCB:
if you turn on this function, machine will doing PCB calibrate
automatically by down-looking camera before running.
(5)
Run speed:
used to set the general speed of machine.
(6)
System set:
setting up the system advanced parameter, need to enter code
“123456”, if machine work fine, then no need to amend the setting.
(7)
Date time set
(8)
Clear statistic log
(9)
Clear system log
(10)
System comp. set:
used to set component entire offset and angle compensation.