Fire sparks but pilot does not light

No gas to fire, check isolators are open. 

Pipe work blockage, clean out.  

Air not fully purged, re purge supply or wait longer.  

Spark grounding to metal work, reset gap correctly.  

Blocked pilot, clean out internally.

Pilot lights but then goes out

Severe restriction in gas supply: clear obstruction.  

Faulty thermocouple, replace pilot unit.  

Blocked pilot, clean out. 

Blocked lint gauze, clean. 

Hold control knob in for longer. 

Check control knob does not foul data plate.

If the pilot will not stay lit there is a problem with dirt, the gas supply, or the thermocouple needs

replacement. Modifications are dangerous and can have a serious unseen effect on safety.

NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. 

Fire does not spark at pilot

HT lead detached, refit.  

Check the spark gap (see section 15.0).

Faulty piezo unit, replace.  

Debris shorting out electrode, clean.  

Spark shorting to metalwork under tray, realign HT lead.

Fire runs for a time and then cuts off

Loose or faulty thermocouple, rectify. 

Blocked pilot, clean out. 

Dirt or lint in pilot aeration hole or on the lint gauze, clean thoroughly. 

If the pilot will not stay lit there is a problem with dirt, the gas supply, or the thermocouple needs

replacement. Modifications are dangerous and can have a serious unseen effect on safety.

NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. 

Pilot flame shrinks when fire is on high

Poor gas flow to fire, check pressure with fire on high.  

If pressure is low, remove any restriction in pipework or valve.  

Check all isolators are adequately sized and fully open. 

Check meter pressure is adequate. 

If the pilot will not stay lit there is a problem with dirt, the gas supply, or the thermocouple needs

replacement. Modifications are dangerous and can have a serious unseen effect on safety.

NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. 

Fire smells when first lit or in use

Newness smell from brand new appliance.  

Leakage occurring.  Carry out leakage test and rectify any problems.  

Combustible materials used in incorrect positions.

10

25.0 TROUBLESHOOTING GUIDE

26.0 REPLACEMENT PARTS

Description

Part number

Glass door assembly

FB/F960003

Gas Valve

FT003155/0

Catalyst

FB/F780079

Pilot unit

FT/F730023

Burner unit

TRAY051

Seal kit for catalyst

IN/F940136

Inlet pressure regulator

FT/F730031

Decorative front frame

FR/F550097

Decorative rear frame

FR/F550098

When ordering spare parts, always give the following information;

1. The model number of the heater.

2. The serial number of the heater.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the heater.

If you encounter any problems, require spare parts, or have any
questions concerning the installation of the heater please contact;

Focal Point (North America)
5555 Pleasantdale Road
Doraville, Georgia 30340
Toll free :1 800 704 6093
Fax: 770 368 8261
E-mail : [email protected]

Manufactured by :

Focal Point Fires plc.
Christchurch, Dorset
United Kingdom BH23 2BT

Содержание F500070

Страница 1: ...alled Appliance WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER WARNING DO NOT BUILD A WOOD FIRE DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES This is an unvented gas fired heater It uses air oxygen fr...

Страница 2: ...y not be operating correctly 2 Section Contents Page No 1 0 General Information 2 2 0 Inventory 2 3 0 Appliance Data 2 4 0 Important Safety Information 2 5 0 Codes 3 6 0 Combustion and Ventilation Air 3 7 0 Site Requirements 4 8 0 Preparing the Appliance 5 9 0 Mounting the Appliance 5 10 0 Checking the Burner 6 11 0 Final Fitting of the Frame Assembly 6 12 0 Connecting a Gas Line 6 13 0 Checking t...

Страница 3: ...ned from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit This Focal Point Unvented Gas Room Heater is certified by OMNI Test Laboratories Inc t...

Страница 4: ... as a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distance of 20 of the appliance sides No such materials are permitted directly above the appliance regardless of distance The minimum clearance to the ceiling above the appliance is 32 measured from the top of the appliance glass panel Combustible mat...

Страница 5: ...d on a studded wall with conventional 16 stud spacing then a wall mounting plate is supplied to enable this First locate the studs and using suitable fixings screw the mounting plate to the wall via the four mounting holes The heater may then be hung onto the mounting plate The bottom of the heater may be secured onto the lower mounting studs using the wingnuts or the hex nuts provided Mark the po...

Страница 6: ...h the pipe to the heater controls and burner Failure to do so could prevent the heater from operating reliably The heater gas inlet connection is 3 8 NPT at the regulator located below the burner in the right hand side of the heater When tightening up the joint to the regulator hold the regulator securely with a wrench to prevent the regulator from moving Turn on gas supply and test for gas leaks ...

Страница 7: ...Inspect the burner and the catalysts and clean if necessary with a soft brush 5 Disconnect the gas supply 6 Undo the four screws retaining the burner support brackets to the base and rear of the firebox 7 Remove the burner unit strip off the burner pipes and clean thoroughly 8 Clean the in line restrictor pilot assembly and the burner tube Do not attempt to remove the pilot injector as this can ca...

Страница 8: ...es Position gas sample probe directly over a cata lyst via the outlet grille on top of the appliance Record the carbon diox ide CO2 concentration and then the carbon monoxide CO concentration as displayed by the analyzer also noting the units in which the values are expressed Most analyzers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per...

Страница 9: ...under section B above If you do not smell gas go to next step 6 The pilot is located on the left side behind the burner Figure 11 7 Depress control knob in and turn counterclockwise to the SPARK position Figure 10 and hold there for a few seconds Note If you are running the heater for the first time or after an extended period of non use it will be necessary to press the control knob all the way i...

Страница 10: ... fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check meter pressure is adequate If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effec...

Страница 11: ...ner fixing points WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY As our policy is one of continuous improvement and development we hope therefore you will understand we must retain the right to amend details and or specifications without prior notice DO00555...

Отзывы: