P a g e
|
29
Issue No - 4(11/08/21)
PANACHE 8040 INSTALLATION INSTRUCTIONS
Four sided trim.
Position the four magnets provided with the decorative trim on each of the four corners of the fire
box flange.
Using the slip frame as an internal guide locate the trim over the frame and fix into position using
the four magnets.
Commissioning the Appliance
Checking gas soundness and running pressure.
Turn on the supply to the appliance and check for soundness in accordance with the current
codes of practice.
Turn off the gas supply at the external isolation valve.
Remove the pressure test point screw from the inlet elbow and connect the pressure gauge.
Turn on the gas to the appliance at the isolation valve.
Light the appliance as described in the user instruction section. Page 5 turn on (startup).
Check the inlet pressure is 20 mbar +/- 1.0 mbar for natural gas with other appliances running.
Turn off gas supply, at the isolation valve. Disconnect the pressure gauge and replace the
pressure test point screw.
Turn on the appliance and check the pressure test point for soundness with detection fluid.
Содержание PANACHE 8040
Страница 1: ...PANACHE 8040 Instruction for User Installation Servicing For use in the UK ...
Страница 13: ...P a g e 12 Issue No 4 11 08 21 PANACHE 8040 USERS INSTRUCTIONS ...
Страница 16: ...P a g e 15 Issue No 4 11 08 21 PANACHE 8040 USERS INSTRUCTIONS Locate log D onto the pin of charcoal A ...
Страница 38: ...P a g e 37 Issue No 4 11 08 21 Wiring Diagram PANACHE 8040 MAINTENANCE INSTRUCTIONS ...
Страница 51: ...P a g e 50 Issue No 4 11 08 21 ...
Страница 52: ...P a g e 51 Issue No 4 11 08 21 ...
Страница 53: ...P a g e 52 Issue No 4 11 08 21 ...
Страница 54: ...P a g e 53 Issue No 4 11 08 21 ...