SECTION SIX Regulations and Warnings (installation instruction)
•
This appliance must only be installed in Great Britain or Ireland.
•
The appliance is available in natural gas only.
•
This appliance must be installed on a suitable outside wall.
•
No special ventilation bricks or vents are required into the room containing the appliance.
•
In GB (Great Britain)
It is the law that all gas appliances must be installed by a competent person; i.e. a GAS SAFE registered installer, in
accordance with the current Gas Safety (Installation and Use) Regulations (as amended), all relevant parts of the
local and national building regulations and all relevant recommendations of the current British Standards. Failure to
do so could lead to prosecution.
The following are the relevant codes of practice and British Standards: -
B.S. 5871 PART 2
B.S. 5440 PART 1
B.S. 6891
B.S. 1945
Note:- This appliance must be installed to current versions of the above standards and include any relevant
amendments.
The Building Regulations issued by The Department of the Environment.
The Building Standards (Scotland) (Consolidated) Regulations issued by The Scottish Development Office.
•
IN IE, (Ireland)
The appliance must be installed by a competent person and installed in accordance with the current edition of
I.S.813 Domestic Gas Installation, the current building regulations, and the current ETCI rules for electrical
installation, if appropriate.
WARNINGS
•
As this appliance has components, which get very hot as with all such fires, it is recommended that a
fireguard should be used for the protection of children, the elderly, or the infirm. Fireguards should conform
to B.S.6539 (1984) (Fireguards for use with solid fuel appliances).
•
During initial use, an odour may be evident. This will soon disappear if the fire is run on its maximum setting
for a few hours.
•
Care must be taken to prevent any damage being caused to surrounding soft furnishing or decoration, e.g.
wall coverings may become discoloured if placed too close to the appliance.
•
To reduce heat transfer to the surround
it is recommended that the header is packed with “Rockwool”
Содержание INFINITY 800HD BF UBL
Страница 32: ...32 LT 8381 ISS 01 800 HD B F with UBL FAULT FINDING INSTRUCTIONS FAULT FINDING CHARTS ...
Страница 34: ...34 LT 8381 ISS 01 800 HD B F with UBL FAULT FINDING INSTRUCTIONS FAULT FINDING CHARTS 1 ...
Страница 37: ...www charltonandjenrick co uk 37 LT 8381 ISS 01 Register your appliance online today to activate your warranty ...
Страница 39: ...www charltonandjenrick co uk 39 LT 8381 ISS 01 ...
Страница 40: ...40 LT 8381 ISS 01 ...
Страница 42: ...42 LT 8381 ISS 01 ...
Страница 43: ...www charltonandjenrick co uk 43 LT 8381 ISS 01 ...