25
LT
6312 (ISS 3)
REPLACEMENT OF INJECTOR
1.
Repeat operations 1-7 for removal of gas control.
2.
Undo the two screws retaining the silencer bracket.
3.
Lift away the silencer; noting its position the cut out slot pointing down, it must be put back in exactly the
same orientation.
4.
Unscrew the locking nut fixing injector to mounting bracket and silencer retaining bracket clean or replace as
necessary.
5.
Re-assemble the in reverse order and check assembly for gas soundness.
6.
Turn on gas supply, check for gas soundness and recommission appliance.
Replacement of Oxy-Pilot Assembly
NOTE: If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and
replaced as a complete unit it is a NON SERVICABLE ITEM.
1.
Repeat operations 1-4 for removal of gas control.
2.
Disconnect the pipe from the gas control to the pilot burner
3.
Disconnect the thermocouple connection from the rear of the gas control.
4.
Remove ignition lead from pilot assembly.
5.
Remove the two screws securing the oxy-pilot to the burner.
6.
Before replacing ensure the code number for Oxy-Pilot replacement is suitable.
7.
Re-assemble the in reverse order and check assembly for gas soundness.
8.
Turn on the gas supply, check for gas soundness and recommission appliance
REPLACEMENT OF CONTROL UNIT (EDB)
1.
Repeat operations 1-7 for removal of gas control.
2.
Disconnect leads from control unit and remove 4 bolts.
3.
Re-assemble in the reverse order.
4.
Turn on the gas supply, check for gas soundness and recommission appliance.