www.charltonandjenrick.co.uk 

20 

LT6312 (ISS 3) 

VENTILATION 

 

In the United Kingdom no special ventilation bricks or vents are required into the room containing the appliance, 
provided normal adventitious room ventilation exists. The installer must satisfy this point by carrying out a 
mandatory spillage test. 

 

In the Republic of Ireland permanent ventilation must comply with the rules in force 

 

SECTION NINE To Install the Appliance (installation instructions) 

 

EXAMINE FLUE / CHIMNEY

 

Check that the flue/chimney conforms to the required specifications as previously stated.  Examine the condition 
and carry out any remedial work.  If the flue/chimney has been used for solid fuel or oil, it should be swept prior to 
appliance installation. A smoke test must be carried out to check that satisfactory smoke clearance has been 
established.  If all the smoke is not drawn into the flue, pre-heat the flue with a blowtorch or similar and re-check.  If 
there is any uncertainty examine for the cause and, if necessary, seek expert advice. 

 

CONNECTING THE GAS SUPPLY 

Determine where the gas supply is to be connected to the appliance.  This may be done from the front of the unit 
from either the left or right side, or a concealed fitting from the rear. 

 

GAS CONCEALED CONNECTION 

If the supply is to be a concealed connection it would be advisable to route 8mm O/D half hard copper tube to the 
rear right side of the fireplace opening, taking into account the requirements of BS 6891 1988 dealing with enclosed 
pipes. Form the tube so that it enters the fire via the blind grommet at the rear of the appliance. A 8mm restrictor 
elbow can be positioned under the burner assembly on the right-hand side connected to the gas supply pipe and its 
outlet connected to the gas appliance.  

Note: pipework in the opening of the fireplace to the rear of the appliance must be suitably wrapped in accordance 
with the regulations. 

 

GAS CONNECTION FROM THE FRONT 

Connections may be made from the front of the appliance from either the left or right in 8-mm diameter pipe.  If a 
left-hand connection is required the tube should be routed behind the bezel plate under the gas control tap and 
onto the inlet elbow.  The inlet elbows should be rotated to the required position.   A suitable isolating cock should 
always be fitted in the supply feed to the fire to facilitate servicing. 

 

 

 

Содержание 2000 Plus Extra Remote

Страница 1: ...vicelogandfuturereference For use in Great Britain and Ireland Literature NO 6312 ISS 3 IMPORTANT This appliance is guaranteed for 12 months subject to conditions The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and appliance has been registered online ...

Страница 2: ...opposite page and ensure your installer has filled in the appropriate checklist This in no way reduces your statutory rights Your warranty commences from the date of purchase and you must retain your receipt or invoice as proof of a purchase date THIS EXTENDED WARRANTY SPECIFICALLY EXCLUDES GLASS AND SOFT REFRACTORY COMPONENTS THE BULB AND ANY BATTERIES Terms and Conditions 1 The appliance must be...

Страница 3: ...d and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance The service eng...

Страница 4: ...suggest you record the following details here and keep the receipt as proof of purchase This information may be asked for when you contact the helpdesk MODEL 2000 Plus Extra Remote Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the base of the appliance behind the control cover Retailer Name Address Date Of Purchase ...

Страница 5: ... securely wrapped in polythene and be clearly labelled RCF waste These materials are not classified as hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste INTRODUCTION The PARAGON 2000 Xtra Remote as been designed and tested to the requirements of EN 509 and is suitable for use in GB Great Britain and IE Ireland The PARAGON 2000 Xtra Remote incorporate...

Страница 6: ...e battery power gets too low The appliance incorporates a safety device in the form of an Oxygen Depletion System which constantly monitors the oxygen in the room and will cause the fire to switch off if the oxygen level reduces for instance due to insufficient ventilation or a blocked flue If this regularly occurs do not attempt to relight the appliance until a qualified engineer has checked it t...

Страница 7: ...ion hole in the pilot body see photograph being partial blocked with dust pet hairs or other foreign matter The source of this debris could be such things as carpet fibres decorating or pets etc To clean the pilot remove the fire front and ashpan The pilot is located on the right hand side of the appliance any debris in or around the aeration hole should be removed using the nozzle of a vacuum cle...

Страница 8: ...iate button low setting or high setting There are 5 heat settings and the fire will give a double bleep when the maximum or minimum heat setting is reached To switch off the appliance press the OFF button or if the appliance is to be switch off for a short period it is recommended that the standby button be used This switches the main burner off but leaves the pilot on and will extend battery life...

Страница 9: ...n be used providing they are a nickel metal hydride type 1 5V AA with a minimum capacity of 2200mAh Using AA Lithium batteries will give more operations A Lift off fret and ash pan B The battery power pack or holder is located at the left hand side of the burner carefully slide the battery holder forward and replace all six batteries as a complete set or recharge as appropriate WARNING batteries w...

Страница 10: ...y deposits A vacuum cleaner may only be used after the loose components and moulded shapes have been removed CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A DELICATE SURFACE AND SHOULD NOT BE WIPED OR RUBBED FUEL BED LAYOUT COAL OPTION Ensure the BASE MATRIX is in position as shown located against the rear edge of the burner outlet Locate the LEFT HAND and RIGHT HAND FRO...

Страница 11: ...nsist of 5 off shaped as coal A 9 off shaped as coal B Separate the coal into the two size groups Lay first row of loose coal 4 off B and 2 off A coals as shown so that they bridge across the gap Lay second row of loose coals B and A shapes as shown ...

Страница 12: ...Matrix L R Front Pebbles Number Pebbles as below PEBBLE LAYOUT Warning Take great care when positioning the pebbles to avoid marking the black linings Ensure the BASE MATRIX is in position as shown located against the rear edge of the burner outlet Pebble identification QTY Heart Shape 1 Oblong Shape 4 Large Shape 3 Medium Shape 2 Small Shape 2 Total 12 ...

Страница 13: ... rail and lean back against the BASE MATRIX Note it is most important that they are located in their correct positions They are marked on the rear L for LEFT HAND FRONT PEBBLE and R for RIGHT HAND FRONT PEBBLE Lay one row of pebbles at the front of the fire as shown Lay another row of loose pebbles shown ...

Страница 14: ... with the current Gas Safety Installation and Use Regulations 1998 as amended The chimney or flue should be checked annually to ensure clearance of combustion products Ventilation in the United Kingdom This appliance does not normally require purpose built ventilation but if for any special reason purpose built ventilation is provided it should be checked periodically to ensure freedom from obstru...

Страница 15: ... 7 2 V is available as an optional extra Data Label Location Behind trim Gas Connection 8 mm OD Tube NOTE The efficiency of this appliance has been measured as specified in BS7977 1 2009 A1 2013 and the result is 56 8 The gross calorific value of the fuel has been used for this efficiency calculation GasTec have certified the test data from which it has been calculated The efficiency value may be ...

Страница 16: ...wing chimneys A conventional brick or stone chimney A pre cast flue conforming to BS 1289 Pt 1 or Pt 2 A metal flue and box conforming to BS 715 further details are covered in later text A non combustible hearth must be provided to comply with the building regulations or a suitable proprietary fire surround with a 100 degrees C rating During initial firing an odour may be evident This is the binde...

Страница 17: ... open The chimney should be swept prior to installation if not new CLASS TWO PRE CAST A pre cast flue conforming to the requirements of BS 1289 part 1 2 A suitable fire resisting fire surround will be required spaced out to the correct thickness between the face of the flue blocks and the rear of the appliance frame IMPORTANT the flue restrictor plate must be removed when the appliance is installe...

Страница 18: ...lace opening a fire resisting hearth must also be provided symmetrically disposed about the fireplace opening a minimum thickness of 12 mm with the perimeter 50mm above floor level The width must extend a minimum of 150 mm either side of the fireplace opening and a depth of 300 mm thickness of spacer if a spacer is used Purpose built superimposed fire resistant hearths and back panels specified as...

Страница 19: ... is used by elderly infirm or young persons The installer MUST explain to the user that the area immediately in front of the appliance must always be keep clear of combustible items other than the floor covering which must be fixed CLEARANCE TO SHELF Minimum clearance from hearth to underside of combustible shelf should be 700mm provided shelf depth 150mm or less This height may be reduced to 640m...

Страница 20: ...s supply is to be connected to the appliance This may be done from the front of the unit from either the left or right side or a concealed fitting from the rear GAS CONCEALED CONNECTION If the supply is to be a concealed connection it would be advisable to route 8mm O D half hard copper tube to the rear right side of the fireplace opening taking into account the requirements of BS 6891 1988 dealin...

Страница 21: ...r to the fireplace first with wood screws and wall plugs then screw firebox to spacer box using screws provided OPTIONAL CABLE FIXING SYSTEM Available on request from PARAGON FIRES for use when fixing to 18 openings or when it is desirable not to drill the fireplace fascia it may not be possible to use the cable fixing system with some pre cast flues Drill 4 holes in the rear of the fireplace open...

Страница 22: ...instances e g when an alternative fret or ash pan cover is used it may be necessary to reposition the remote control eye an alternative position is specified below Position the remote control eye as shown with the front edge level with the ash pan cover Secure in position with insulation tape as shown Position the tape at the rear of the eye do not place any tape over the eye as this may cause rec...

Страница 23: ...hould be repeated with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors to that room opened and the extractor fan running COMPLETION OF INSTALLATION Fit the decorative trim with the four magnetic strips placed two on each vertical side flange of the firebox one at the top and one at the bottom Offer the decorative trim up squarely an...

Страница 24: ... The loose fuel bed components should only be replaced as a complete set with no extra components added FUEL BED CLEANING Important Refer to the Health Safety Notice located on page 5 of this booklet before cleaning or replacing any refractory material The loose fuel bed components are delicate and they should be handled with great care They may be removed for cleaning They can be brushed very gen...

Страница 25: ...rom the same manufacturer and replaced as a complete unit it is a NON SERVICABLE ITEM 1 Repeat operations 1 4 for removal of gas control 2 Disconnect the pipe from the gas control to the pilot burner 3 Disconnect the thermocouple connection from the rear of the gas control 4 Remove ignition lead from pilot assembly 5 Remove the two screws securing the oxy pilot to the burner 6 Before replacing ens...

Страница 26: ...www charltonandjenrick co uk 26 LT6312 ISS 3 SECTION NINE Wiring Diagram maintenance instructions Attach to the valve ...

Страница 27: ...27 LT6312 ISS 3 ...

Страница 28: ...www charltonandjenrick co uk 28 LT6312 ISS 3 ...

Страница 29: ...29 LT6312 ISS 3 Register your appliance online today to active your warranty ...

Страница 30: ...led in the manufacturer s instructions Hearth Requirements where fitted Is the hearth constructed from non combustible material Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm BS5871 or as per manufacturer s instructions Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening BS6871 or to manufacturer s instructi...

Страница 31: ...ufacturer s specified spare part when replacing controls SERVICE 01 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 03 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 04 Date Engineer name Company name Telephone No...

Страница 32: ...re Box Grommet Burner Tray Box Assembly Warning Label Fire Guard Cable Clips 1 Alum 1 Plastic Ceramics Set Part no 5568 Fixing Kit 0705 Canopy Part No 5003 Restrictor Elbow male AAA 1 5V LR3 Batteries x 2 Remote Control Hand Set Battery Holder with Lead Battery Insulation Blanket AA Battery 12 Owners Book ID Label Packing Labels Serial Number Inspector ...

Отзывы: