Bank Battery Type Select
Select the battery type connected to this bank. Note there are
multiple screens on this page by pressing the UP/DOWN ar-
rows. Select the Battery type. If the battery type is unknown,
GEL mode should be selected. Note the bank number in the
upper right hand corner. [Fixed Bank Output mode: Fixed
Bank Output mode is only available on Bank 1. If Fixed Bank
Output mode is selected, Banks 2−4 are automatically turned
off.]
Bank Output Voltage
This screen allows the output voltage to be customized. Fixed
Band Output mode has only a single setting. All other active
modes have Bulk (Equalize) and Float settings. Press the UP/
DOWN arrows to change the setting. You may return to de-
fault setting for the selected battery type by changing the bat-
tery type to another type and saving the settings. Then, re−
enter the setup mode and reset the battery type back to it’s
original value.
Maximum Output Amperage
Set the maximum output amperage for this bank. Care should
be used when setting the Maximum Output Amperage. If the
battery’s capacity is limited, select a lower output amperage.
Likewise, if the battery’s capacity is large, a higher maximum
output amperage should be selected.
Temperature Select
Sets the temperature reading to Farehnheit or Celsius.