C6050A, C6050B
v2.0
High efficiency wide input voltage
PFC programmable Charger
90V~265VAC input
For 4S~15S LiPo/LiFe battery
1~55Amps 3050W max.
www.chargery.com
page
3
total
19
Protection functions
1.
Over current protection
2.
Over voltage protection
3.
Charge power protection
4.
Over temperature protection
5.
Anti spark on battery connection
6.
Reverse polarity protection of battery connection
7.
Prevent any cell from over charging, adjust charge current automatically fit with Chargery BMS
Main battery type and cell count
Battery
Type
Cell
Count
Output
Voltage/V
Terminal charge Voltage per cell
Charge
current
Terminal
charge
current/A
Charge
Mode
Min.
Type
Max.
LiPo
4S-13S
10-55
2.75
4.20
4.20
1.0-55A
5-60%
Pre-charge
CC/CV and
maintain
Li-ion
4S-13S
10-55
2.50
4.10
4.15
LiFe
5S-14S
10-55
2.00
3.65
3.75
LiTo
7S-20S
10-55
1.50
2.70
2.70
Pb
6S-22S
10-55
1.75
2.40
2.45
- delta Voltage /mV
Min.
type
Max.
NiMH
/NiCd
Auto
10-55
150
300
1000
CC
Warning
1.
For any lithium battery, such as LiPo, LiFePO4, Li-ion, NMC, LiTo and other Li battery, the PCM
(Protection Circuit Module), BMS, cell monitor, saver etc. must be built-in the battery pack,
because the charger don’t monitor each cell voltage, even the total battery voltage don’t be
over charged, the single cell voltage is possible be over charged, special for larger impedance
cell. So if no PCM or BMS protect each cell from over charged, it is very dangerous.
2.
Before charge, the cell count must be setup correctly, it is very important. Cell count is not the
cell quantity in a battery pack, it means cell count of connection in series, even 5 cells
connected in parallel, the cell count is 1 NOT 5. Please according to your battery pack rated
voltage and the following table get the cell count.