Hold coupling nut and regulator
as shown for proper connection
to LP cylinder valve.
C
Str
ght
ai
6.
Turn the coupling nut clockwise to tighten to a full
solid stop. The regulator will seal on the back-check
feature in LP cylinder valve, resulting in some
resistance.
An additional one-half to three
quarters turn is required to complete connection.
Tighten by hand only - do not use tools.
NOTE:
If you cannot complete connection, disconnect
regulator and repeat steps 5 and 6. If you are still
unable to complete the connection,
do not use this
Regulator!
Leak Testing Valve, Hose and Regulator
1. Turn control knob to OFF.
2.
Be sure regulator is tightly connected to LP cylinder.
3.
Completely open LP cylinder valve by turning hand
wheel counter clockwise. If you hear a
rushing sound
,
turn gas off immediately. There is a major leak at the
connection.
Correct before proceeding
.
4.
Brush soapy solution on areas where bubbles are
shown.
5. “If growing”
bubbles appear, there is a leak. Close
LP cylinder valve immediately and re-tighten
connections.
If leaks cannot be stopped “do not try
to repair”.
Call for replacement parts. Order new
parts by giving the part number from the parts list to
the Service Center at 1-800-241-7548.
6.
Always close LP cylinder valve after performing leak
test by turning hand wheel clockwise.
Safety Tips
s
Before opening LP cylinder valve, check the coupling
nut for tightness.
s
When appliance is not in use, turn off control knob
and LP cylinder valve.
s
Never move appliance while in operation or still hot.
s
The regulator may make a humming or whistling
noise during operation. This will not affect safety or
use of fireplace.
s
Check appliance before each use for buildup of
any leaves or other material that will burn or block
the burner ports. Clean when needed before
using. Have appliance inspected annually by a
qualified service person.
6
WARNING
• Do not insert any foreign objects into the
valve outlet. You may damage the valve and
cause a leak. Leaking propane may result in
explosion, fire, severe personal injury or
death.
• Never attempt to attach this appliance to the
self-contained LP gas system of a camper
trailer or motor home.
WARNING
• Do not use appliance until leak checked.
• If leak is detected at any time, STOP and call
your fire department.
• If you cannot stop a gas leak,
immediately
close LP cylinder valve and call a LP gas
supplier or your fire department!