R-Series Electric
28
CQF3473 v.01
Operation & Service
April 17, 2018
Troubleshooting Chart (continued)
Symptom
Possible Cause(s)
Corrective Action
Interstage pressure relief valve
pops off.
1. Defective compressor valves.
2. Improper valve installation.
1. Install new valves.
2. Verify proper valve placement.
Excessive oil consumption.
1. Dirty air filter.
2. Wrong oil viscosity.
3. Oil leaks.
4. Worn piston rings.
5. Scored cylinder
1. Clean or replace.
2. Refill with proper viscosity oil.
3. Tighten bolts. Replace gaskets.
4. Replace rings.
5. Replace cylinder.
Air escapes from centrifugal
unloader when unit is running
1. Centrifugal unloader release valve
dirty or detective.
1. Clean or replace valve
Air escapes from centrifugal
unloader when unit is stopped.
1. Check valve stuck in open position.
1. Replace check valve.
Warning – Relieve tank pressure
before servicing.
System does not alternate
(Duplex units only)
1. Starter tripped.
2. Loose wiring in alternator.
3. Defective alternator.
4. Defective motor.
1. Reset starter. If starter trips repeatedly,
have electrical system inspected by an
electrician.
2. Check and tighten all wiring
connections.
3. Replace alternator.
4. Replace motor.