21
ELECTRICAL SERVICE (Cont.)
Thermostat Locations and Adjustments
Refer to Fig. 7
Electric tank heat
is controlled by two thermostats.
1. The control thermostat which regulates the
temperature.
2. The high limit thermostat which protects from
overheating.
Location:
Both thermostats are located on front of tank, inside
a black enclosure box behind the front access panel.
Adjustment:
The Control Thermostat
has an adjustment screw
on one side.
• The thermostat is wired Normally Closed.
• Turn the adjustment screw clockwise to increase
the temperature in the tank and counterclockwise
to decrease the temperature in the tank.
The High Limit Thermostat
is not adjustable.
It contains a red reset button in its center.
• The red button pops out if the temperature
in the tank exceeds 210˚F/99˚C.
• Press the red button in to reset the high limit.
Determine the cause of the high temperature condition.
Refer to Fig. 7 and Fig. 8
Electric Booster Heat
is controlled by two thermostats.
1. The control thermostat which regulates the
temperature.
2. The high limit thermostat which protects from
overheating.
3. The tank(s) have a control and a high limit thermostat.
Location:
The control thermostat
is enclosed in a black box mounted
on the front of the wash tank behind the front access panel.
The high limit thermostat
is enclosed in a box mounted
on top of the booster tank.
Adjustment:
The control thermostat
has an adjustment screw on one side.
• The thermostat is wired Normally Closed.
• Turn the adjustment screw clockwise to increase the booster
tank temperature and counterclockwise to decrease the booster
tank temperature.
The high limit thermostat
is a bimetal snap design.
It is not adjustable.
• A button with a red dot in the center pops out when
the temperature exceeds 210˚F/99˚C.
• Press the red reset button in to reset the high limit.
Determine the cause of the high temperature condition.
Figure 8
Booster Thermostat Locations
Figure 9
Booster – High Limit
Thermostat
Control
Thermostat
High Limit
Thermostat
Control Thermostat
High limit
Thermostat
Figure7
Tank Heat Thermostats
ELECTRICAL SERVICE
Содержание PP-28 Corner
Страница 4: ...REVISION RECORD CONT REVISIONS ii ...
Страница 43: ...35 REPLACEMENT PARTS REPLACEMENT PARTS ...
Страница 44: ...36 REPLACEMENT PARTS 5 2 5 1 5 4 3 5 5 5 6 9 7 10 11 12 A B A A 8 Figure 22 Panels ...
Страница 48: ...40 REPLACEMENT PARTS 2 1 1 3 6 7 3 5 4 A A A 8 9 10 B B B Figure 24 Cable Pulley Assembly ...
Страница 50: ...42 REPLACEMENT PARTS 2 3 3 4 8 7 6 5 3 5 5 5 3 9 10 1 11 12 Figure 25 Counterweight System ...
Страница 64: ...56 REPLACEMENT PARTS 2 3 6 4 5 1 7 Figure 32 Scrap Screens Baskets ...
Страница 75: ...67 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 83: ...75 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 84: ...76 REPLACEMENT PARTS 3 5 6 4 5 5 5 1 2 5 3 Figure 40 Side Mount Booster Cabinet ...
Страница 86: ...78 REPLACEMENT PARTS 1 2 3 4 7 8 6 9 10 4 11 12 13 5 Figure 41 Pump Assembly ...
Страница 88: ...80 REPLACEMENT PARTS 3 4 5 6 7 8 10 1 2 9 11 11 Figure 42 Machine Control Panel ...
Страница 92: ...84 REPLACEMENT PARTS 7 7 3 6 5 9 1 2 4 8 Figure 44 Booster Control Cabinet Single Tank Canister Shown ...
Страница 94: ...86 REPLACEMENT PARTS 0 1 2 1 2 3 4 6 7 8 5 Figure 45 Vent Fan Control Cabinet Optional ...
Страница 96: ...88 REPLACEMENT PARTS 1 2 3 4 5 Utensils loose items Large Pots Pans Baking sheets Baking Pans Figure 46 Racks ...
Страница 98: ...90 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 99: ...91 ELECTRICAL SCHEMATICS ELECTRICAL SCHEMATICS ...
Страница 103: ...98 ...
Страница 104: ...99 ...
Страница 105: ......