TROUBLESHOOTING
OPERATOR TROUBLESHOOTING (CONT.)
Troubleshooting Guide
In order to find the cause of a breakdown or abnormal operating condition in your dishwasher
please ensure that:
1. All switches are ON
2. Drain and overflow tube are in place and seated
3. Wash and rinse nozzles are clean
4. Scrap screen(s) and scrap basket are properly positioned
5. Spray arms are in their proper positions
6. Thermostat(s) are at their correct setting
7. Sanitizer, detergent, and rinse additive dispensers are adequately filled
8. Doors are fully closed.
If a problem still exists, use the following table for troubleshooting
CONDITION
CAUSE
SOLUTION
Machine will not start
Door not closed.................................. Make sure doors are fully closed
Door safety switch faulty .................. Contact your service agency
Start switch faulty .............................. Contact your service agency
Main switch off .................................. Check disconnect
No rack inserted ................................ Place rack in unit
Overload protector tripped ................ Reset overload in control box
Low or no water
Main water supply is turned off ........ Turn on house water supply
Drain/overflow tube is not
in place and seated ............................ Place and seat drain tube
Machine doors not fully closed ........ Close doors securely
Faulty fill valve .................................. Contact your service agency
Stuck or defective float ...................... Check floats and clean
Clogged ‘Y’ strainer .......................... Clean or replace
Continuous water filling
Stuck or defective float ...................... Check floats and clean
Fill valve will not close...................... Clean or replace
Drain tube not in place ...................... Look for drain tube in tank
Motor not running
Overload protector tripped ................ Reset overload in control box
Defective motor ................................ Contact your service agency
Wash tank water temperature
Incoming water temperature
is low when in use
at machine too low ............................ Raise temperature to 140˚
Defective thermometer ...................... Check or replace
Defective thermostat .......................... Check for proper setting or replace
Defective heater element .................. Check or replace
Low steam pressure .......................... Check steam supply pressure
Defective steam trap .......................... Check or replace
Defective solenoid valve .................... Check or replace
14
Содержание PP-28 Corner
Страница 4: ...REVISION RECORD CONT REVISIONS ii ...
Страница 43: ...35 REPLACEMENT PARTS REPLACEMENT PARTS ...
Страница 44: ...36 REPLACEMENT PARTS 5 2 5 1 5 4 3 5 5 5 6 9 7 10 11 12 A B A A 8 Figure 22 Panels ...
Страница 48: ...40 REPLACEMENT PARTS 2 1 1 3 6 7 3 5 4 A A A 8 9 10 B B B Figure 24 Cable Pulley Assembly ...
Страница 50: ...42 REPLACEMENT PARTS 2 3 3 4 8 7 6 5 3 5 5 5 3 9 10 1 11 12 Figure 25 Counterweight System ...
Страница 64: ...56 REPLACEMENT PARTS 2 3 6 4 5 1 7 Figure 32 Scrap Screens Baskets ...
Страница 75: ...67 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 83: ...75 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 84: ...76 REPLACEMENT PARTS 3 5 6 4 5 5 5 1 2 5 3 Figure 40 Side Mount Booster Cabinet ...
Страница 86: ...78 REPLACEMENT PARTS 1 2 3 4 7 8 6 9 10 4 11 12 13 5 Figure 41 Pump Assembly ...
Страница 88: ...80 REPLACEMENT PARTS 3 4 5 6 7 8 10 1 2 9 11 11 Figure 42 Machine Control Panel ...
Страница 92: ...84 REPLACEMENT PARTS 7 7 3 6 5 9 1 2 4 8 Figure 44 Booster Control Cabinet Single Tank Canister Shown ...
Страница 94: ...86 REPLACEMENT PARTS 0 1 2 1 2 3 4 6 7 8 5 Figure 45 Vent Fan Control Cabinet Optional ...
Страница 96: ...88 REPLACEMENT PARTS 1 2 3 4 5 Utensils loose items Large Pots Pans Baking sheets Baking Pans Figure 46 Racks ...
Страница 98: ...90 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 99: ...91 ELECTRICAL SCHEMATICS ELECTRICAL SCHEMATICS ...
Страница 103: ...98 ...
Страница 104: ...99 ...
Страница 105: ......