8
Do not install isolating valves between compressor outlet and air receiver. This will cause excessive
pressure if valve is closed, and cause injury and equipment damage.
Always use an air pressure regulating device at the point of use. Failure to do so can result in injury or
equipment damage.
●
Do not install in an area where ambient temperature is below 32 degrees F or above 100 degrees F.
●
Do not install unit in an area where air is dirty and/or chemical laden.
●
Unit is not to be installed outdoors.
AIR LINE PIPING
Connection to air system should be of the same size, or larger, than discharge pipe out of unit.
The table gives recommended minimum pipe sizes. A union connection to the unit is
recommended. Install a flexible connector between the discharge of the unit and the air piping.
Piping should be periodically inspected for leaks using a soap and water solution for detection on
all pipe joints. Air leaks waste energy and are expensive.
Minimum Pipe Sizes For Compressor Air Lines
(Based on clean Smooth Schedule 40 Pipe)
MODEL
25
’
50
’
100
’
200
’
300
’
R15BHU
3/4
”
3/4
”
3/4
”
1
”
1
”
Never use plastic pipe or improperly rated metal pipe. Improper piping material can burst and
cause injury or property damage.