MAINTENANCE ANd STORAGE

Storage

The generator should be started at least once every 14 
days and allowed to run for at least 20 minutes . For 
longer term storage, please follow these guidelines .

Generator Storage

1 .  Add a properly formulated fuel stabilizer to the tank .
2 .  Be sure all appliances are disconnected from the 

generator .

3 .  Run the generator for a few minutes so the treated 

fuel cycles through the fuel system and carburetor .

4 .  Turn the fuel valve to the “Off” position .
5 .  Let the generator run until fuel starvation has 

stopped the engine . This usually takes a few minutes .

6 .  The generator needs to cool acompletely before 

cleaning and storage .

7 .  Clean the generator according to the maintenance section .
8 .  Change the oil .
9 .  Remove the spark plug and pour about 1⁄2 ounce 

of oil into the cylinder . Crank the engine slowly to 
distribute the oil and lubricate the cylinder .

10 . Reattach the spark plug .
11 . Store the unit in a clean, dry place out of direct 

sunlight .

disconnect the Battery

1 .  Remove the protective cover from the black/negative 

battery lead .

2 .  Disconnect the black/negative lead from the black/

negative terminal on the battery and store the cap 
screw (M5x10) and lock washer (M5) .

3 .  Repeat steps 1-2 for the red/positive battery lead .
4 .  Store the battery in a cool, dry place .

Charge the Battery

For generators equipped with batteries for electric 
starting, proper battery maintenance and storage 
should be followed . An automatic battery charger with 

Generator exhaust contains odorless and colorless 
carbon monoxide gas .

To avoid accidental or unintended ignition of your 
remote start generator during periods of storage, 
the following precautions should be followed:

 

– When 

storing the generator for short periods of 

time make sure that the Ignition Switch, the Fuel 
Valve and the Battery Switch are set in the 

OFF 

position . 

 

– When 

storing the generator for extended periods 

of time make sure that the Ignition Switch, the 
Fuel Valve and the Battery Switch are set in the 
the the 

OFF position and the battery leads have 

been 

disconnected from the battery . 

dANGER

A Float Charger will maintain the battery condition 
over long storage periods .

NOTE

Our engines work well with 10% or less ethanol 
blend fuels . When using blended fuels there are 
some issues worth noting: 

 

– Ethanol-gasoline blends can absorb more water 

than gasoline alone . 

 

– These blends can eventually separate, leaving 

water or a watery goo in the tank, fuel valve and 
carburetor . 

 

– With gravity-fed fuel supplies, this compromised 

fuel can be drawn into the carburetor and cause 
damage to the engine and/or potential hazards . 

 

– There are only a few suppliers of fuel stabilizer 

that are formulated to work with ethanol blend 
fuels .

 

– Any damages or hazards caused by using 

improper fuel, improperly stored fuel, and/
or improperly formulated stabilizers, are not 
covered by manufacture’s warranty . 

It is advisable to always shut off the fuel supply, 
run the engine to fuel starvation and drain the tank 
when the equipment is not in use for more than 30 
days .

NOTE

Generator Maintenance

Make certain that the generator is kept clean and stored 
properly . Only operate the unit on a flat, level surface in 
a clean, dry operating environment . DO NOT expose the 
unit to extreme conditions, excessive dust, dirt, moisture 
or corrosive vapors .

Use a damp cloth to clean exterior surfaces of the generator .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris 
from the generator . 
Inspect all air vents and cooling slots to ensure that they 
are clean and unobstructed .

DO NOT use a garden hose to clean the generator .

Water can enter the generator through the cooling 
slots and damage the generator windings .

CAUTION

automatic trickle charging capability should be used to 
charge the battery . Maximum charging rate should not 
exceed 1 .5 amps . Follow the instructions included with 
the battery charger . The battery should be fully charged 
at least once per month .

Charge the Battery Cont’d.

Содержание 41532

Страница 1: ...CA 90670 USA 1 877 338 0999 www championpowerequipment com 9000 Starting Watts 7000 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual...

Страница 2: ...the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Ca...

Страница 3: ...ot Overload Generator 14 Capacity 14 Power Management 14 Operation at High Altitude 14 Maintenance and Storage 15 Engine Maintenance 15 Oil 15 Spark Plugs 15 Air Filter 15 Spark Arrester 16 Cleaning 1...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...s metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can...

Страница 7: ...nd let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pump gas di...

Страница 8: ...nt required 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to manually start the en...

Страница 9: ...0 Amp Twist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 6 120 240 Volt AC 30 Amp Twist Lock Receptacl...

Страница 10: ...function requires electrical current from the battery If the Ignition Switch is left in the ON position for extended periods several weeks the battery can be completely drained Moving the Ignition Sw...

Страница 11: ...Wheel Kit 10 Wheel 2 Flange Bolt M10x120 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 2 Other Oil Funnel 1 Oil 1 16 qt 1...

Страница 12: ...he following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generato...

Страница 13: ...off and will stop when the oil level in the crankcase falls below the threshold level CAUTION Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the rec...

Страница 14: ...el Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately below the top of the tank to allow for fuel expansion DO NOT pump gas directl...

Страница 15: ...hen positioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrical...

Страница 16: ...or a period of two 2 weeks or longer please see the Storage section for proper engine and fuel storage NOTE Recoil Start 1 Make certain the generator is on a flat level surface 2 Turn off all electric...

Страница 17: ...evations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING...

Страница 18: ...am element 3 Wash in liquid detergent and water Squeeze thoroughly dry in a clean cloth 4 Saturate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter...

Страница 19: ...ster to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if it is damaged 6 Position...

Страница 20: ...ded periods of time make sure that the Ignition Switch the Fuel Valve and the Battery Switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER A...

Страница 21: ...erference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Страница 22: ...36 37 38 39 40 41 42 43 44 45 41 46 47 48 40 41 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 29 27 86 87 88 89 90 91 92 93 94 95 96 7...

Страница 23: ...9 GB96 10 Washer 10 1 60 ST07FD 02011200 THD Rotor Assembly 1 61 ST05FD 1151600 Air Guide 1 62 ST05FD 1152008 Plug A 1 63 ST05FD 1152009 Plug B 1 64 190FDE 2 GC1 Engine 1 65 ST182FD 1742203 UC Cover H...

Страница 24: ...21 REV 41532 20120918 ENGLISH 41532 Specifications Engine Parts Diagram...

Страница 25: ...RTC Spark plug 1 59 ST188F 1122000 G Ignition Coil 1 60 GB5789 FB6 29 Flange Bolt M6 29 4 61 ST188FD 1130003 CPE Carburetor Insulator Packing 1 Part Number Description Qty 62 ST188F 1134000 Carburetor...

Страница 26: ...23 REV 41532 20120918 ENGLISH 41532 Wiring Diagram Specifications...

Страница 27: ...Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected...

Страница 28: ...r labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any ele...

Страница 29: ...diagnosis parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EM...

Страница 30: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 31: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Отзывы: