background image

REV 41532-20120918  

16

41532

 

ENGLISH

Adjustments

The air-fuel mixture is not adjustable . Tampering with 
the governor can damage your generator and your 
electrical devices and will void your warranty . CPE 
recommends that you contact our service line at
1-877-338-0999 for all other service and/or adjustment 
needs .

Maintenance Schedule

Follow the service intervals indicated in the following 
maintenance schedule . 
Service your generator more frequently when operating 
in adverse conditions . 
Contact our helpline at 

1-877-338-0999 to locate the 

nearest Champion Power Equipment certified service 
dealer for your generator or engine maintenance needs .

Use a damp cloth to clean exterior surfaces of the engine .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris 
from the engine .

Cleaning

DO NOT spray engine with water .

CAUTION

Water can contaminate the fuel system .

Spark Arrester

1 .  Allow the engine to cool completely before servicing 

the spark arrester .

2 .  Remove the three screws holding the cover plate 

which retains the end of the spark arrester to the 
muffler .

3 .  Remove the spark arrester screen .
4 .  Carefully remove the carbon deposits from the spark 

arrester screen with a wire brush .

5 .  Replace the spark arrester if it is damaged .
6 .  Position the spark arrester in the muffler and attach 

with the three screws .

Failure to clean the spark arrester will result in degraded 
engine performance .

CAUTION

MAINTENANCE ANd STORAGE

Federal and local laws and administrative requirements 
indicate when and where spark arresters are required . 
When ordered, spark arresters are required for operation 
of this generator in National Forest lands . In California, 
this generator must not be used on any forest- covered 
land, brush-covered land, or grass- covered land unless 
the engine is equipped with a spark arrester .

NOTE

*To be performed by knowledgeable, experienced owners or 
Champion Power Equipment certified dealers .

Every 8 hours or daily

Check oil level
Clean around air intake and muffler

First 5 Hours

Change oil

Every 50 hours or every season

Clean air filter
Change oil if operating under heavy load or in hot environments

Every 100 hours or every season

Change oil
Clean/Adjust spark plug
Check/Adjust valve clearance *
Clean spark arrester
Clean fuel tank and filter *

Every 250 hours

Clean combustion chamber*

Every 3 years

Replace fuel line

Содержание 41532

Страница 1: ...CA 90670 USA 1 877 338 0999 www championpowerequipment com 9000 Starting Watts 7000 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual...

Страница 2: ...the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Ca...

Страница 3: ...ot Overload Generator 14 Capacity 14 Power Management 14 Operation at High Altitude 14 Maintenance and Storage 15 Engine Maintenance 15 Oil 15 Spark Plugs 15 Air Filter 15 Spark Arrester 16 Cleaning 1...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...s metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can...

Страница 7: ...nd let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pump gas di...

Страница 8: ...nt required 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to manually start the en...

Страница 9: ...0 Amp Twist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 6 120 240 Volt AC 30 Amp Twist Lock Receptacl...

Страница 10: ...function requires electrical current from the battery If the Ignition Switch is left in the ON position for extended periods several weeks the battery can be completely drained Moving the Ignition Sw...

Страница 11: ...Wheel Kit 10 Wheel 2 Flange Bolt M10x120 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 2 Other Oil Funnel 1 Oil 1 16 qt 1...

Страница 12: ...he following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generato...

Страница 13: ...off and will stop when the oil level in the crankcase falls below the threshold level CAUTION Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the rec...

Страница 14: ...el Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately below the top of the tank to allow for fuel expansion DO NOT pump gas directl...

Страница 15: ...hen positioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrical...

Страница 16: ...or a period of two 2 weeks or longer please see the Storage section for proper engine and fuel storage NOTE Recoil Start 1 Make certain the generator is on a flat level surface 2 Turn off all electric...

Страница 17: ...evations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING...

Страница 18: ...am element 3 Wash in liquid detergent and water Squeeze thoroughly dry in a clean cloth 4 Saturate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter...

Страница 19: ...ster to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if it is damaged 6 Position...

Страница 20: ...ded periods of time make sure that the Ignition Switch the Fuel Valve and the Battery Switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER A...

Страница 21: ...erference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Страница 22: ...36 37 38 39 40 41 42 43 44 45 41 46 47 48 40 41 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 29 27 86 87 88 89 90 91 92 93 94 95 96 7...

Страница 23: ...9 GB96 10 Washer 10 1 60 ST07FD 02011200 THD Rotor Assembly 1 61 ST05FD 1151600 Air Guide 1 62 ST05FD 1152008 Plug A 1 63 ST05FD 1152009 Plug B 1 64 190FDE 2 GC1 Engine 1 65 ST182FD 1742203 UC Cover H...

Страница 24: ...21 REV 41532 20120918 ENGLISH 41532 Specifications Engine Parts Diagram...

Страница 25: ...RTC Spark plug 1 59 ST188F 1122000 G Ignition Coil 1 60 GB5789 FB6 29 Flange Bolt M6 29 4 61 ST188FD 1130003 CPE Carburetor Insulator Packing 1 Part Number Description Qty 62 ST188F 1134000 Carburetor...

Страница 26: ...23 REV 41532 20120918 ENGLISH 41532 Wiring Diagram Specifications...

Страница 27: ...Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected...

Страница 28: ...r labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any ele...

Страница 29: ...diagnosis parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EM...

Страница 30: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 31: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Отзывы: