background image

REV 41532-20120918  

4

41532

 

ENGLISH

SAfETy RULES

Improper treatment or use of the generator can 
damage it, shorten its life and void your warranty .

Use the generator only for intended uses .
Operate only on level surfaces .
DO NOT expose generator to excessive moisture, 
dust, or dirt .
DO NOT allow any material to block the cooling slots .
If connected devices overheat, turn them off and 
disconnect them from the generator .
DO NOT use the generator if:

 

– Electrical output is lost

 

– Equipment sparks, smokes or emits flames

 

– Equipment vibrates excessively

CAUTION

Operation of this equipment may create sparks that 

can start fires around dry vegetation .

A spark arrestor may be required . The operator 

should contact local fire agencies for laws or 

regulations relating to fire prevention requirements .

WARNING

Rapid retraction of the starter cord will pull hand and 
arm towards the engine faster than you can let go . 
Unintentional startup can result in entanglement, 
traumatic amputation or laceration .  
Broken bones, fractures, bruises or sprains could result .

When starting engine, pull the starter cord slowly 
until resistance is felt and then pull rapidly to avoid 
kickback .
DO NOT start or stop the engine with electrical 
devices plugged in .

WARNING

Fuel and fuel vapors are highly flammable and 
extremely explosive . 
Fire or explosion can cause severe burns or death .  
Unintentional startup can result in entanglement, 
traumatic amputation or laceration . 

When adding or removing fuel:

Turn the generator off and let it cool for at least two 
minutes before removing the fuel cap . Loosen the 
cap slowly to relieve pressure in the tank .
Only fill or drain fuel outdoors in a well-ventilated area .
DO NOT pump gas directly into the generator at the 
gas station . Use an approved container to transfer 
the fuel to the generator .
DO NOT overfill the fuel tank .
Always keep fuel away from sparks, open flames, 
pilot lights, heat and other sources of ignition .
DO NOT light or smoke cigarettes .

When starting the generator:

DO NOT attempt to start a damaged generator . 
Make certain that the gas cap, air filter, spark plug, 
fuel lines and exhaust system are properly in place .
Allow spilled fuel to evaporate fully before 
attempting to start the engine .
Make certain that the generator is resting firmly on 
level ground .

When operating the generator:

DO NOT move or tip the generator during operation .
DO NOT tip the generator or allow fuel or oil to spill .

When transporting or servicing the generator:

Make certain that the fuel shutoff valve is in the off 
position and the fuel tank is empty .
Disconnect the spark plug wire .
When storing the generator:
Store away from sparks, open flames, pilot lights, 
heat and other sources of ignition .

dANGER

Exceeding the generator’s running capacity can 
damage the generator and/or electrical devices 
connected to it .

DO NOT overload the generator .
Start the generator and allow the engine to stabilize 
before connecting electrical loads .
Connect electrical equipment in the off position, 
and then turn them on for operation .
Turn electrical equipment off and disconnect before 
stopping the generator .
DO NOT tamper with the governed speed . 
DO NOT modify the generator in any way .

CAUTION

Содержание 41532

Страница 1: ...CA 90670 USA 1 877 338 0999 www championpowerequipment com 9000 Starting Watts 7000 Running Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual...

Страница 2: ...the store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Ca...

Страница 3: ...ot Overload Generator 14 Capacity 14 Power Management 14 Operation at High Altitude 14 Maintenance and Storage 15 Engine Maintenance 15 Oil 15 Spark Plugs 15 Air Filter 15 Spark Arrester 16 Cleaning 1...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...s metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can...

Страница 7: ...nd let it cool for at least two minutes before removing the fuel cap Loosen the cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pump gas di...

Страница 8: ...nt required 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to manually start the en...

Страница 9: ...0 Amp Twist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 6 120 240 Volt AC 30 Amp Twist Lock Receptacl...

Страница 10: ...function requires electrical current from the battery If the Ignition Switch is left in the ON position for extended periods several weeks the battery can be completely drained Moving the Ignition Sw...

Страница 11: ...Wheel Kit 10 Wheel 2 Flange Bolt M10x120 for Wheel 2 Bushing 2 Flat Washer 10 2 Nut M10 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Nut M8 2 Other Oil Funnel 1 Oil 1 16 qt 1...

Страница 12: ...he following tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generato...

Страница 13: ...off and will stop when the oil level in the crankcase falls below the threshold level CAUTION Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the rec...

Страница 14: ...el Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately below the top of the tank to allow for fuel expansion DO NOT pump gas directl...

Страница 15: ...hen positioning generator Failure to follow proper safety precautions may void manufacturer s warranty Do not operate or store the generator in rain snow or wet weather Using a generator or electrical...

Страница 16: ...or a period of two 2 weeks or longer please see the Storage section for proper engine and fuel storage NOTE Recoil Start 1 Make certain the generator is on a flat level surface 2 Turn off all electric...

Страница 17: ...evations the standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING...

Страница 18: ...am element 3 Wash in liquid detergent and water Squeeze thoroughly dry in a clean cloth 4 Saturate in clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter...

Страница 19: ...ster to the muffler 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if it is damaged 6 Position...

Страница 20: ...ded periods of time make sure that the Ignition Switch the Fuel Valve and the Battery Switch are set in the the the OFF position and the battery leads have been disconnected from the battery DANGER A...

Страница 21: ...erference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Страница 22: ...36 37 38 39 40 41 42 43 44 45 41 46 47 48 40 41 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 29 27 86 87 88 89 90 91 92 93 94 95 96 7...

Страница 23: ...9 GB96 10 Washer 10 1 60 ST07FD 02011200 THD Rotor Assembly 1 61 ST05FD 1151600 Air Guide 1 62 ST05FD 1152008 Plug A 1 63 ST05FD 1152009 Plug B 1 64 190FDE 2 GC1 Engine 1 65 ST182FD 1742203 UC Cover H...

Страница 24: ...21 REV 41532 20120918 ENGLISH 41532 Specifications Engine Parts Diagram...

Страница 25: ...RTC Spark plug 1 59 ST188F 1122000 G Ignition Coil 1 60 GB5789 FB6 29 Flange Bolt M6 29 4 61 ST188FD 1130003 CPE Carburetor Insulator Packing 1 Part Number Description Qty 62 ST188F 1134000 Carburetor...

Страница 26: ...23 REV 41532 20120918 ENGLISH 41532 Wiring Diagram Specifications...

Страница 27: ...Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected...

Страница 28: ...r labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any ele...

Страница 29: ...diagnosis parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EM...

Страница 30: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 31: ...ting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof...

Отзывы: