201033 - 6000W PORTAbLE GENERATOR
TROUbLESHOOTING
29
TROUbLESHOOTING
Problem
Cause
Solution
Engine will not start.
No fuel.
Add fuel.
Faulty spark plug.
Clean and adjust spark plug or replace.
Low oil level.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Spark plug wire loose.
Attach wire to spark plug.
Fuel valve is closed.
Open fuel valve.
Engine switch OFF.
Press engine switch ON.
Old fuel or water in fuel.
Drain fuel and replace with fresh fuel.
Flooded with fuel.
Let unit stand for 10 mins.
CO Shield™ module has been removed
or tampered with.
Re-install module or contact technical support.
Engine starts but runs roughly.
Choke in the wrong position.
Move choke until it stops under RUN position or
push in completely.
Dirty air filter.
Clean or replace air filter.
Dirty fuel valve.
Clean the fuel valve.
Clogged spark arrestor.
Clean spark arrestor.
Engine shuts down during operation.
Out of fuel.
Fill fuel tank.
Low oil level.
Fill crankcase to the proper level. Place generator
on a flat, level surface.
If equipped, CO Shield™ shutoff due to
accumulating carbon monoxide if the red
LED light blinks on the panel.
Move generator to an open, outdoor area. Point
exhaust away from people and buildings. Move
to fresh air and get medical help if sick, dizzy, or
weak.
If equipped, CO Shield™ shutoff due
system fault if the yellow LED light blinks
on the panel.
Start to confirm yellow LED light blinks when/if
generator shuts off. If CO Shield continues sense
the fault and shuts off, contact technical support.
Clogged spark arrestor.
Clean spark arrestor.
Engine starts and shuts off right away.
If equipped, CO Shield™ shutoff due to
accumulating carbon monoxide if the red
LED light blinks on the panel.
Move generator to an open, outdoor area. Point
exhaust away from people and buildings. Move
to fresh air and get medical help if sick, dizzy, or
weak.
If equipped, CO Shield™ shutoff due
system fault if the yellow LED light blinks
on the panel.
Start to confirm yellow LED light blinks when/if
generator shuts off. If CO Shield continues sense
the fault and shuts off, contact technical support.
Both CO Shield™ LEDs not blinking 8
times upon start up.
Starting the generator within 1 minute
after being manually shutoff, not a CO
shutoff event.
Wait 1 minute before trying to restart the
generator. The LEDs should then blink eight (8)
times.