Your generator requires some assembly. This unit ships from our 
factory without oil. It must be properly serviced with fuel and oil 
before operation.

If you have any questions regarding the assembly of your 
generator, call our Technical Support Team at 1-877-338-0999. 
Please have your serial number and model number available.

Unpacking

1.  Set the shipping carton on a solid, flat surface.

2.  Remove everything from the carton except the generator.

3.  Carefully cut each corner of the box from top to bottom. Fold 

each side flat on the ground to provide a surface area to work 
with the generator.

Install the Wheel Kit

 

CAUTION

The wheel kit is not intended for over-the-road use. 

Install the Wheels

1.  Before adding fuel and oil, tip the generator onto it’s recoil 

end.

2.  Remove wheel hub cap (B) from wheel by inserting a small 

screwdriver into the slot provided and pry upward.

3.  Slide the roll pin (C) through the wheel (A) from the outside.

4.  Slide the roll pin through the mount point on the frame.

5.  Secure with the r-clip (D).

6.  Re-install hub cap on wheel.

7.  Repeat to attach the second wheel.

D

A

C

b

Install the Support Leg

1.  Attach the support leg (E) to the generator frame with flange 

bolts (F) and flange lock nuts (G).

2.  Slowly tip the generator back down so that it rests on the 

wheels and support Leg.

G

E

f

Add Engine Oil

 

WARNING

DO NOT attempt to crank or start the engine before it has been 
properly filled with the recommended type and amount of oil. 
Damage to the generator as a result of failing to follow these 
instructions will void your warranty.

 

NOTICE

The generator rotor has a sealed, pre-lubricated ball bearing 
that requires no additional lubrication for the life of the bearing.

 

NOTICE

The recommended oil type for typical use is 

10W-30 

automotive oil

. However, using the listed conventional oils 

shown in the “Recommended Engine Oil Type” chart may be 
used for typical use including the first 5 hours of the break-in 
run time period of the engine.

If running generator in extreme temperatures, refer to the 
“Recommended Engine Oil Type” chart.

-20

0

20

40

60

Ambient temperature

Recommended Engine Oil Type

80

100

120

-28.9

°F
°C

-17.8

-6.7

4.4

15.6

26.7

37.8

48.9

10W-30

5W-30 Full Synthetic

10W-40

5W-30

Содержание 201033

Страница 1: ...Failure to do so could result in serious injury This manual should remain with the product Specifications descriptions and illustrations in this manual are as accurate as known at the time of publicat...

Страница 2: ...all carbon monoxide risks you ll be better prepared to protect your family from this colorless oderless threat CARBON MONOXIDE SAFETY THE BIG PICTURE KNOW THE SYMPTOMS Headache Nausea Shortness of br...

Страница 3: ...GFCI 22 Stopping the Engine 23 Moving the Generator 23 Operation at High Altitude 24 Maintenance 24 Cleaning the Generator 24 Changing the Engine Oil 24 Cleaning and Adjusting the Spark Plug 25 Clean...

Страница 4: ...ort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docu...

Страница 5: ...parts can entangle hands feet hair clothing and or accessories Traumatic amputation or severe laceration can result Keep hands and feet away from rotating parts Tie up long hair and remove jewelry DO...

Страница 6: ...nce is felt and then pull rapidly to avoid kickback DO NOT start or stop the engine with electrical devices plugged in and turned on CAUTION Exceeding the generator s running capacity can damage the g...

Страница 7: ...into the generator at the gas station Always use an approved container to transfer the fuel to the generator DO NOT overfill the gasoline tank Always keep gasoline away from sparks open flames pilot...

Страница 8: ...ion Changes B Updated dieline This artwork belongs to Champion Power Equipment The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the...

Страница 9: ...g an electrocution hazard A transfer switch must be used when connecting to a building Fire Explosion Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns...

Страница 10: ...YMBOL MEANING On Stop or Off High CO Warning Move generator to an open outdoor area Move to fresh air and get medical help if sick dizzy or weak CO Shield System Fault Electrical issue end of life Her...

Страница 11: ...volume 3 Turn the fuel valve to ON position 4 Press engine switch to the ON position 5 Move choke lever to CHOKE position 6 Pull the recoil cord 7 Move the choke lever to RUN position 8 Plug in desir...

Страница 12: ...art the engine 5 Fuel Valve Used to turn fuel supply on and off to engine 6 Air Filter Protects the engine by filtering dust and debris from the intake air 7 Recoil Starter Used to manually start the...

Страница 13: ...e and hertz 3 Circuit Breakers Push Reset Protects the generator against electrical overloads RECEPTACLES A Y 120 240V AC 30A Locking NEMA L14 30R May be used to supply electrical power for operation...

Страница 14: ...in hertz Example 60 0 hertz Run Time R Run time of the generator for the current session Example 6 hours Total Run Time Total run time of the generator since first operation Example 16 hours Intelliga...

Страница 15: ...2 fl oz 1100 ml Oil Funnel 1 Assembly Parts Wheels 8 in 20 3 cm Never Flat Wheel A 2 Wheel Hub Cap B 2 Roll Pin C 2 Large R clip D 2 Engine Vibration Mounts Support Leg with Vibration Mounts E 2 Flang...

Страница 16: ...on the frame 5 Secure with the r clip D 6 Re install hub cap on wheel 7 Repeat to attach the second wheel D A C B Install the Support Leg 1 Attach the support leg E to the generator frame with flange...

Страница 17: ...k in period Using synthetic oil does not decrease the recommended oil change interval Full synthetic 5W 30 oil will aid in starting in cold ambient 41 F 5 C temperatures Add Fuel DANGER Gasoline vapor...

Страница 18: ...e and or create potential hazards If a fuel stabilizer is used confirm that it is formulated to work with ethanol gasoline blends Any damages or hazards caused by using ethanol blended gasoline higher...

Страница 19: ...ica si est enfermo mareado o d bil Aller l air frais et obtenir de l aide m dicale si malade tourdi ou faible PROCESS Colors LPN 1607 L SF Rev B Size 276 4 x 82 3 mm Artwork Notes 2mm safe margin to b...

Страница 20: ...wn into occupied or confined spaces Always carefully consider wind and air currents when positioning generator Always allow generators to properly cool before transport or for storage purposes Failure...

Страница 21: ...l of the recoil cord After first pull move choke to RUN position for up to 3 pulls of the recoil cord Too much choke leads to spark plug fouling engine flooding due to lack of incoming air This will c...

Страница 22: ...1 Add this number to the number calculated in step 2 Starting wattage is the surge of power needed to start some electric driven equipment Following the steps listed under Power Management will guaran...

Страница 23: ...minutes to stabilize internal temperatures of the engine and generator 3 Press the engine switch to the OFF position 4 Turn the fuel valve to the OFF position Important Always ensure that the fuel va...

Страница 24: ...originally supplied standard main jet must be used Operating the engine with the wrong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance...

Страница 25: ...spark required for ignition 4 Make certain the spark plug gap is 0 028 0 031 in 0 7 0 8 mm SPARK PLUG GAP 5 Refer to the spark plug types in Specifications when replacing the plug 6 Firmly re install...

Страница 26: ...ke and muffler FIRST 5 HOURS BREAK IN Change oil EVERY 50 HOURS OR ANNUALLY Clean air filter Change oil if operating under heavy load or in hot environments EVERY 100 HOURS OR ANNUALLY Change oil Clea...

Страница 27: ...valve to the ON position 3 Use the drain bolt on the carburetor to empty any excess gasoline from the gasoline tank and carburetor into an appropriate container Use a funnel and appropriate hose if ne...

Страница 28: ...ure Recommended Engine Oil Type 80 100 120 28 9 F C 17 8 6 7 4 4 15 6 26 7 37 8 48 9 10W 30 5W 30 Full Synthetic 10W 40 5W 30 NOTICE Temperature will affect engine oil and engine performance Change th...

Страница 29: ...ing carbon monoxide if the red LED light blinks on the panel Move generator to an open outdoor area Point exhaust away from people and buildings Move to fresh air and get medical help if sick dizzy or...

Страница 30: ...and tighten wiring connections GFCI tripped Reset GFCI receptacle breakers by first pushing the TEST button then the RESET button until green LED illuminates Contact the help line Other Contact the he...

Страница 31: ...or connected incorrectly to any electrical component Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other Exclusi...

Страница 32: ...condition exits CPE will repair your small off road engine SORE and equipment at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE This Emissions Control System is w...

Страница 33: ...shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replace...

Страница 34: ...Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other p...

Отзывы: