30
100883 - 27 TON LOg SPLiTTER
SPECifiCATiONS
fuel Specifications
Use regular unleaded gasoline with a minimum octane rating of 87
and an ethanol content of less than 10% by volume. DO NOT USE
E15 or E85. DO NOT OVERFILL.
Gasoline Capacity
...................................
0.8 gal. (3.1 L)
Spark Plug Specifications
OEM Type
..............................................
NHSP F6RTC
Replacement Type
......................
NGK BPR6ES or equivalent
Gap
..................................
0.028-0.031 in. (0.7-0.8 mm)
Valve Specifications
Intake Clearance
...............
0.0039-0.0059 in. (0.1-0.15 mm)
Exhaust Clearance
.............
0.0059-0.0079 in. (0.15-0.2 mm)
NOTiCE
A technical bulletin regarding valve adjustment procedures is
available at www.championpowerequipment.com.
important Message About Temperature
Your product is designed and rated for continuous operation at
ambient temperatures up to 104°F (40°C). When your product is
needed it may be operated at temperatures ranging from
2°F (-10°C) to 122°F (50°C) for short periods of time. If exposed
to temperatures outside this range during storage, it should be
brought back within this range before operation. In any event, the
product must always be operated outdoors, in a well-ventilated
area and away from doors, windows and vents.