background image

100594 - 1600 PORTABLE POWER STATION

IMPORTANT SAFETY INSTRUCTIONS

8

Safety and Dataplate Labels

These labels warn you of potential hazards that can cause serious injury. Read them carefully.

If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.

LABEL

DESCRIPTION

A

Safety Symbols

B

3

4

6

0

-L

-SF-B

 

WARNING

 

ADVERTISSEMENT

 

CAUTION

 

MISE EN GARDE

Do not overcharge the internal battery. See Operator’s Manual. Do not smoke, strike a match, or cause a spark in the vicinity of the power pack. Only charge the internal 
battery in a well ventilated area. Risk of Explosion. This equipment has arcing or sparking parts which should not be exposed to flammable vapors. Risk of Electric Shock 
and Risk of Fire. This device is not to be stored in a vehicle. For use only with 201107 battery pack. / Ne pas surcharger la batterie interne. Consulter le manuel de 
l’opérateur. Il ne faut pas fumer, allumer une allumette ou produire des étincelles à proximité du bloc d'alimentation. Charger la batterie uniquement dans un endroit bien 
aéré. Risque d'explosion. Cet équipement comporte des pièces susceptibles de produire des arcs ou des étincelles qui ne doivent pas être exposées à des vapeurs 
inflammables. Risques de décharge électrique et d'incendie. Le dispositif ne doit pas être rangé dans un véhicule. À utiliser uniquement avec la batterie 201107.

Risk of Electric Shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Risk of Electric Shock. Connect only to 
properly grounded outlets. Risk of Injury To Persons. Do not use this product if the power cord or the battery cables are damaged in any way. This device is not intended 
for use in a commercial repair facility. This device is intended to be stored indoors when not in use. This device shall not be stored or left outdoors when not in use. This 
device is intended for temporary use outdoors and reasonable care should be exercised when using this device in wet conditions.
Risque de décharge électrique. Ne pas enlever le couvercle. Aucune des pièces à l'intérieur ne peut être réparée par l'utilisateur. L'entretien courant doit être effectué 
par un personnel d'entretien qualifié. Risque de décharge électrique. Brancher l'unité uniquement à des prises de courant correctement mises à la masse. Risque de 
blessure aux personnes. Ne pas utiliser ce produit si le cordon d'alimentation ou les câbles de batterie sont endommagés de quelque façon. Le dispositif n'est pas 
destiné à être utilisé dans un atelier de réparation commercial. Le dispositif est destiné à être rangé à l'intérieur lorsqu'il n'est pas utilisé. Le dispositif ne doit pas être 
rangé ou laissé à l'extérieur lorsqu'il n'est pas utilisé. Le dispositif est destiné à une utilisation à l'extérieur temporaire et il faut faire preuve d'une prudence raisonnable 
lorsqu'il est utilisé dans des conditions humides.

Safety Warning

C

3436

-L

-P

R

-A

AC OUTPUT / SORTIE CA

DC OUTPUT / SORTIE CC

(3) NEMA 5-15R

MODEL 
MODÈLE 

Certified to ANSI/CAN/UL Standard 2743 
Certifié selon la norme ANSI/CA/UL 2743 

SERIAL NUMBER
N° DE SÉRIE

DOM / FAB

RUNNING WATTS

WATTS CONTINUE
STARTING/PEAK WATTS
WATTS AU DÉMARRAGE / DE CR

Ê

TE

120V, 60Hz, 1600W

100594

XXXX

1600

3200/4500

(1) USB Type C+PD3.0 60W
(1) USB Type C+PD3.0 60W

(2) USB A / (2) USB A

(1) USB Type C QC3.0
(1) USB Type C QC3.0

5V, 2.1A

(1) Anderson Powerpole APP
(1) APP Anderson Powerpole

12V, 20A

(1) 12V Automotive
(1) 12V Automobile

12V, 10A

BATTERY / BATTERIE

Lithium Ion
Lithium Ion

RATED VOLTAGE (VDC)
TENSION NOMINALE (V CC)

46.8

CHAMPION POWER EQUIPMENT, INC.

12039 SMITH AVENUE
SANTA FE SPRINGS, CA 90670
USA / É.-U.
1-877-338-0999
WWW.CHAMPIONPOWEREQUIPMENT.COM
MADE IN CHINA / FABRIQUÉ EN CHINE

5022532

 

CHEMISTRY
CHIMIE

CURRENT CAPACITY (Ah)
CAPACITÉ ACTUELLE (Ah) 

35

5V/9V/12V/15V/20V,3A, Fixed

3.3~21V PPS

5V/3A,9V/3A,12V/2.5A, Fixed

3.6~12V PPS

PACK CAPACITY (Wh)
BLOC ALIMENTATION (Wh) 

1638

Charging Temperature (

°F/°C)

Température de Charge (

°F/°C)

32 – 113
(0 – 45)

5 – 104

(

−15

 – 40)

Discharge Temperature (

°F/°C)

Température de Décharge

 

(

°F/°C)

XXXXXXX

Power Station Dataplate

D

3464-L-PR-A

CAUTION / MISE EN GARDE

SERIAL NUMBER
N° DE SÉRIE

DOM / FAB

DC050003

Input

Entrée

Output

Sortie

XXXX

Voltage (V)
Voltage (V) 

Current (A)
Courant (A)

120 

(AC/CA)

MAX 4.5

55 

(DC/CC)

8

Frequency (Hz)
Fréquence (Hz)

60

/

Watts (W)
Watts (W)

/

440

CHAMPION POWER EQUIPMENT, INC.

12039 SMITH AVENUE
SANTA FE SPRINGS, CA 90670
USA / É.-U.
1-877-338-0999
WWW.CHAMPIONPOWEREQUIPMENT.COM
MADE IN CHINA / FABRIQUÉ EN CHINE

Indoor use only. Charge only Li-ion rechargeable batteries. Other types 
of batteries may burst causing personal injury and damage. / Convient 
à un usage intérieur seulement. Utiliser pour charger uniquement les 
accumulateurs du type Li-ion. D’autres types d’accumulateurs 
pourraient éclater et causer des blessures oudommages. 

MODEL 
MODÈLE 

XXXX

AC Charger Dataplate

E

3491-L-PR-A

CAUTION / MISE EN GARDE

SERIAL NUMBER
N° DE SÉRIE

DOM / FAB

DC050002

Input

Entrée

Output

Sortie

XXXX

Voltage (VDC)
Voltage (V CC) 

Current (A)
Courant (A)

10–28

MAX 25

55

8

Watts (W)
Watts (W)

/

440

CHAMPION POWER EQUIPMENT, INC.

12039 SMITH AVENUE
SANTA FE SPRINGS, CA 90670
USA / É.-U.
1-877-338-0999
WWW.CHAMPIONPOWEREQUIPMENT.COM
MADE IN CHINA / FABRIQUÉ EN CHINE

Indoor use only. Charge only Li-ion 
rechargeable batteries. Other types 
of batteries may burst causing 
personal injury and damage. /
Convient à un usage intérieur 
seulement. Utiliser pour charger 
uniquement les accumulateurs du 
type Li-ion. D’autres types 
d’accumulateurs pourraient éclater 
et causer des blessures 
oudommages. 

MODEL 
MODÈLE 

XXXX

DC Charger Dataplate

F

3

7

0

1

-L

-SF-

A

.1

 WARNING

 ADVERTENCIA

 AVERTISSEMENT

To avoid electric shock, do not 

touch the charging terminals of 

the power station when the charger 

modules are not in position.

Pour éviter les chocs électriques, ne touchez 

pas les bornes de charge de la centrale 

lorsque les modules de charge ne sont pas 

en place.

Para evitar descargas eléctricas, no toque los 

terminales de carga de la central eléctrica cuando 

los módulos del cargador no estén en posición.

      

3

7

0

1

-L

-SF-

A

.2

 WARNING

 ADVERTENCIA

 AVERTISSEMENT

Pour éviter les chocs électriques, ne touchez 

pas les bornes de charge de la centrale 

lorsque les modules de charge ne sont pas 

en place.

Para evitar descargas eléctricas, no toque los 

terminales de carga de la central eléctrica cuando 

los módulos del cargador no estén en posición.

To avoid electric shock, do not 

touch the charging terminals of 

the power station when the charger 

modules are not in position.

Charging Terminals 

Warning

Top

A

B

D

F

F

Back

Inside

C

E

Содержание 100594

Страница 1: ...mpionpowerequipment com READ AND SAVE THIS MANUAL This manual contains important safety precautions which should be read and understood before operating the product Failure to do so could result in se...

Страница 2: ...nnect DC Solar Charge Harness 20 Recommended Solar Panels 21 Using APP Port 21 Operation 22 Using the Power Station 22 Standby Mode 22 LED Light 22 Connecting Electrical Loads 23 Resetting the Output...

Страница 3: ...ort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docu...

Страница 4: ...ratings on the Power Station and accessory products you intend to use CAUTION In outdoor conditions this device is intended for temporary outdoor use only Reasonable care should always be exercised wh...

Страница 5: ...wer tools Connect only to properly grounded outlets To reduce risk of damage to the electric plug and cord pull the plug rather than the cord when disconnecting the Power Station Never use the cord fo...

Страница 6: ...rain snow damp or wet locations Do not overcharge the Power Station internal battery Always connect to properly grounded outlets Never use Power Station or charger in the presence of explosive atmosp...

Страница 7: ...es and counties it may be illegal to dispose of these batteries in standard household waste To dispose the battery safely apply tape over any exposed connectors to prevent accidental shorting of the p...

Страница 8: ...TS WATTS AU D MARRAGE DE CR TE 120V 60Hz 1600W 100594 XXXX 1600 3200 4500 1 USB Type C PD3 0 60W 1 USB Type C PD3 0 60W 2 USB A 2 USB A 1 USB Type C QC3 0 1 USB Type C QC3 0 5V 2 1A 1 Anderson Powerpo...

Страница 9: ...electrician to determine grounding requirements before operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Shield eyes Explosive gases...

Страница 10: ...roduct uses lithium ion Li ion batteries Local state or federal laws prohibit disposal of Li ion batteries in ordinary trash In the United States and Canada a large network of over 30 000 battery drop...

Страница 11: ...for 3 seconds to power ON OFF Press for 1 second to power AC outlets ON OFF Circuit Breaker Reset Push Parallel Connection s AC Output DC Output 12V Direct Current Ground Terminal Neutral Floating Ne...

Страница 12: ...eld button 5x within three seconds 4 Plug in desired devices NOTICE To protect sensitive electronics as the Power Station s battery level drops below 30 THD Shield is designed to shut off AC power out...

Страница 13: ...e 120V AC 60Hz 4 5A MAX Used to charge the Power Station from a regular wall outlet Uses included cord 7 DC Fast Charge MPPT Solar 10V 28V DC 25A MAX APP Anderson Power Pole DC Used to charge the Powe...

Страница 14: ...ole May be used to supply electrical power for operation of 12 Volt DC 20 Amp electrical loads B z 12V DC 10A Regulated Automotive May be used to supply electrical power for operation of 12 Volt DC 10...

Страница 15: ...11 11 120V The 120V AC outlets are powered on and ready for use when steady blue Steady red if overloaded or fault has occurred in 120V AC inverter or outlets see Resetting the Output section 12 THD...

Страница 16: ...to charge to full 0 watts out battery is at 10 H 1 2 W Charging Watts Example 384 Watts charging in 0 watts out battery is at 10 1 2 W W Discharging Hours Example 2 0 Hours to empty 0 watts in batter...

Страница 17: ...HD steady red AC output shut off due to THD above 5 1 2 W W THD Shield Disabled THD 5 Example THD Shield disabled icon will be steady blue when THD is below 5 AC output will not shut off until battery...

Страница 18: ...experiencing a fault See figure to the right 12V DC USB Port Fault Example Fault in 12V DC port location 1 APP and USB port location 3 USB PD Check devices cables or lower load Press overload reset bu...

Страница 19: ...pt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause und...

Страница 20: ...itive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Charging From Wall NOTICE The Power Statio...

Страница 21: ...Solar Panel 200 Watt 12 Volt 200 MC4 Bluetti SP120 120 MC4 Bluetti SP200 200 MC4 ECOFLOW EFSOLAR 160W 160 MC4 Any solar panel rated between 10 28V with MC4 or APP connectors can be used The Power Stat...

Страница 22: ...n a pure sine wave 5 THD The letters THD will appear in red See THD Shield Total Harmonic Distortion section 4 To turn THD Shield off press THD Shield button 5x within three seconds 5 Plug in desired...

Страница 23: ...C outlets 1 Unplug all devices 2 For AC output errors only Check to see if Power Station s circuit breaker is tripped If tripped push in to reset 3 Press the reset button 4 If overload is due to high...

Страница 24: ...Management Use the following formula to convert voltage and amperage to watts Volts Amps Watts To prolong the life of your Power Station and attached devices follow these steps to add electrical load...

Страница 25: ...ly with water No user serviceable parts for maintenance required Water can enter the Power Station through the cooling slots and damage the Power Station electronics 1 Use a damp cloth to clean exteri...

Страница 26: ...5 3 cm Width 10 8 in 27 5 cm Height 12 3 in 31 3 cm Battery Specifications Chemistry Lithium ion NMC Pack Rated Output Voltage 46 8 Pack Max Output Voltage 55 Pack Capacity 1638 Wh Single Cell Equival...

Страница 27: ...perature warning light Turn the unit off place it in the shade or a cooler area and let it cool down Check that the unit is not overloaded Unit is too cold Check display for flashing red Low Temperatu...

Страница 28: ...you reach 440W of charging power Unit is nearing 100 battery level and is slowing down to a safer charging rate The charging power and rate is reduced as the battery level gets closer to 100 to safely...

Страница 29: ...ot apply to parts and or labor if the product is deemed to have been misused neglected involved in an accident abused loaded beyond the product s limits modified installed improperly or connected inco...

Отзывы: