OPERATION

Do not operate or store the generator in rain, snow, 
or wet weather.

Using a generator or electrical appliance in wet 
conditions, such as rain or snow, or near a pool or 
sprinkler system, or when your hands are wet, could 
result in electrocution.

WARNING

WARNING

During operation the muffler and exhaust fumes 
produced will become hot. If adequate cooling and 
breathing space are not supplied, or if the generator 
is blocked or contained, temperatures can become 
extremely heated and may lead to fire.

Surge Protection

Electronic devices, including computers and many 
programmable appliances use components that are 
designed to operate within a narrow voltage range and 
may be affected by momentary voltage fluctuations. 
While there is no way to prevent voltage fluctuations, you 
can take steps to protect sensitive electronic equipment. 
1.  Install UL1449, CSA-listed, plug-in surge suppressors 

on the outlets feeding your sensitive equipment.  
Surge suppressors come in single- or multi-outlet 
styles. They’re designed to protect against virtually 
all short-duration voltage fluctuations.

Voltage fluctuation may impair the proper 
functioning of sensitive electronic equipment.

CAUTION

Grounding

The generator system ground connects the frame to the 
ground terminals on the power panel.

 

– The generator (stator winding) is isolated from the 

frame and from the AC receptacle ground pin.

 

– Electrical devices that require a grounded receptacle 

pin connection will not function if the receptacle 
ground pin is not functional.

Generator Location

NEVER operate the generator inside any building, 
including garages, basements, crawlspaces and sheds, 
enclosure or compartment, including the generator 
compartment of a recreational vehicle. Please consult 
your local authority. In some areas, generators must 
be registered with the local utility. Generators used at 
construction sites may be subject to additional rules and 
regulations. Generators should be on a flat, level surface 
at all times. (Even while not in operation) Generators 
must have at least 5 ft. (1.5 m) of clearance from all 
combustible material. In addition to clearance from 
all combustible material, generators must also have 
at least 3 ft. (91.4 cm) of clearance on all sides to 
allow for adequate cooling, maintenance and servicing. 
Generators should never be started or operated in the 
back of a SUV, camper, trailer, in the bed of a truck 
(regular, flat or otherwise), under staircases/stairwells, 
next to walls or buildings, or in any other location that 
will not allow for adequate cooling of the generator 
and/or the muffler. DO NOT contain generators during 
operation. Allow generators to properly cool before 
transport or storage.
Place the generator in a well-ventilated area. DO NOT 
place the generator near vents or intakes where exhaust 
fumes could be drawn into occupied or confined 
spaces. Carefully consider wind and air currents when 
positioning generator.
Failure to follow proper safety precautions may void 
manufacturer’s warranty.

Содержание 100215

Страница 1: ...d Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important safety instructions are included in this manual MADE IN CHINA REV 100215 20150718 Recoil Start 100215 MODEL NUMBER 12039 Smith Ave Santa Fe...

Страница 2: ...ge on the cover For residents of California WARNING This product contains chemicals known to the State of California to cause cancer or birth defects and other reproductive harm AN IMPORTANT MESSAGE A...

Страница 3: ...er Management 13 Maintenance and Storage 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 16 Stor...

Страница 4: ...t prior notice Since CPE CET highly value how our products are designed manufactured operated and are serviced and also highly value your safety and the safety of others we would like you to take the...

Страница 5: ...s situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result...

Страница 6: ...cking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can result in...

Страница 7: ...can cause a fire or explosion if ignited LPG is heavier than air and can settle in low places while dissipating LPG has a distinctive odor added to help detect potential leaks quickly In any petroleum...

Страница 8: ...anual for future reference Generator Controls and Features 1 Fuel Valve Used to turn fuel supply on and off to engine 2 Choke Used to start the engine 3 Air Filter Protects the engine by filtering dus...

Страница 9: ...operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 4 120 Volt AC 30 Amp Receptacle NEMA TT 30 May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single ph...

Страница 10: ...or ships with the following parts Wheel Kit 8 in 20 3 cm Wheel 2 Pin Roll 16 x 10 x 97 for Wheel 2 R Shape Pin 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Handle 1 Flange Bo...

Страница 11: ...wheel kit and support leg Install the Wheel Kit Install the Support Leg 1 Attach the support leg to the generator frame with flange bolts M8x16 and flange lock nuts M8 2 Tip the generator slowly so th...

Страница 12: ...ife of the bearing NOTE The recommended oil type is 10W 30 automotive oil NOTE Synthetic oil may be used after the 5 hour initial break in period Using synthetic oil does not increase the recommended...

Страница 13: ...0 pound capacity LPG tanks with Type 1 right hand Acme threads Verify the requalification date on the tank has not expired All new cylinders must be purged of air and moisture prior to filling Used cy...

Страница 14: ...lectrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional Generator Location NEVER operate the generator inside any building...

Страница 15: ...ompany power lines You are responsible for ensuring that your generator s electricity does not feed back into the electric utility power lines If the generator will be connected to a building electric...

Страница 16: ...d attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabilize 5 P...

Страница 17: ...2 threads from running out of the fill hole If using the dipstick to check oil level DO NOT screw in the dipstick while checking NOTE Engine Maintenance To prevent accidental starting remove and grou...

Страница 18: ...and muffler Check hoses for leaks First 5 Hours Change oil Every 50 hours or every season Clean air filter Change oil if operating under heavy load or in hot environments Every 100 hours or every sea...

Страница 19: ...alve on the generator to the Off position 6 The generator needs to cool completely before cleaning and storage 7 Disconnect the fuel hose from the LPG cylinder 8 Clean the generator according to the m...

Страница 20: ...ap is 0 7 0 8 mm or 0 028 0 031 in Oil Use 10W 30 automotive oil Oil capacity is up to 0 6 qt 0 6 L DO NOT OVERFILL Please reference the following chart for recommended oil types for use in the genera...

Страница 21: ...ED In W L BLACK YELLOW BLUE Br W G B W BROWN IGNITION COIL SPARKING PLUG ENGINE BLOCK B EXW FW MW1 L Y Y AVR Br 25A OIL LEVEL SW Y CONTROL BOX BLOCK Y G Y EARTH TERMINAL W W W G Y G Y G Y Y Y L L R W...

Страница 22: ...9 21 24 25 26 27 28 29 30 12 13 18 32 33 34 35 43 46 47 38 36 37 50 51 54 52 53 55 56 57 58 34 59 60 61 62 34 63 64 65 66 67 68 69 70 71 72 73 74 58 75 76 77 78 79 80 81 82 84 85 34 83 44 45 86 30 20...

Страница 23: ...t M6 x 12 9 43 122 070200 08 76 Plate 1 44 1 823 0408 Screw M4 x 8 2 45 1 93 04 Lock Washer 4 2 46 1 97 1 04 Washer 4 2 Part Number Description Qty 47 27 136000 01 Pressure Reducing Valve Assembly 1 4...

Страница 24: ...44 46 47 21 22 23 24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86 87 88 76 59 12 77 96 33 81 73 15 20 48 14 101 5...

Страница 25: ...003 00 Arm Governor 1 51 1 6177 06 Flange Nut M6 3 52 21 110001 00 Shaft Governor Arm 1 53 22 123000 01 Ignition Coil Silicon Rubber 1 54 1 5789 0625 Flange Bolt M6 25 2 Part Number Description Qty 55...

Страница 26: ...l Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air...

Страница 27: ...or is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical component Insta...

Страница 28: ...parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EMISSION CON...

Страница 29: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 30: ...ets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of origin...

Отзывы: