14

100215

 

ENGLISH

The owner/operator is responsible for all periodic 
maintenance.

Complete all scheduled maintenance in a timely manner. 
Correct any issue before operating the generator.

Never operate a damaged or defective generator.

Tampering with the factory set governor will void 
your warranty.

Air Filter

1.  Remove the snap-on cover holding the air filter to 

the assembly.

2.  Remove the foam element. 
3.  Wash in liquid detergent and water. Squeeze 

thoroughly dry in a clean cloth.

4.  Saturate in clean engine oil. 
5.  Squeeze in a clean, absorbent cloth to remove all 

excess oil.

6.  Place the filter in the assembly.
7.  Reattach the air filter cover and snap in place.

For service or parts assistance, contact our help 
line at 

1-877-338-0999

NOTE

Maintenance, replacement, or repair of emission 
control devices and systems may be performed 
by any non-road engine repair establishment or 
individual.

NOTE

WARNING

WARNING

Improper maintenance will void your warranty.

WARNING

Oil Cont’d.

MAINTENANCE AND STORAGE

Once oil has been added, a visual check should show 
oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw 
in the dipstick while checking.

NOTE

Engine Maintenance

To prevent accidental starting, remove and ground spark 
plug wire before performing any service.

Oil

Change oil when the engine is warm. Refer to the oil 
specification to select the proper grade of oil for your 
operating environment.
1.  Remove the oil drain plug with a 12 mm socket and 

extension. (not included)

2.  Allow the oil to drain completely.
3.  Replace the drain plug.
4.  Remove oil fill cap/dipstick to add oil.
5.  Add up to 0.6 qt. (0.6 L) of oil and replace oil fill 

cap/dipstick. DO NOT OVERFILL.

6.  Dispose of used oil at an approved waste 

management facility.

Spark Plugs

1.  Remove the spark plug cable from the spark plug.
2.  Use the spark plug tool (not included) to remove the 

plug.

3.  Inspect the electrode on the plug. It must be clean 

and not worn to produce the spark required for 
ignition.

4.  Make certain the spark plug gap is 0.7 - 0.8 mm or 

(0.028 - 0.031 in.).

5.  Refer to the spark plug recommendation chart when 

replacing the plug.

6.  Carefully thread the plug into the engine.
7.  Use the spark plug tool (not included) to firmly 

install the plug.

8.  Attach the spark plug wire to the plug.

0.7 - 0.8 mm

0.028 - 0.031 in.

Содержание 100215

Страница 1: ...d Watts PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important safety instructions are included in this manual MADE IN CHINA REV 100215 20150718 Recoil Start 100215 MODEL NUMBER 12039 Smith Ave Santa Fe...

Страница 2: ...ge on the cover For residents of California WARNING This product contains chemicals known to the State of California to cause cancer or birth defects and other reproductive harm AN IMPORTANT MESSAGE A...

Страница 3: ...er Management 13 Maintenance and Storage 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arrester 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 16 Stor...

Страница 4: ...t prior notice Since CPE CET highly value how our products are designed manufactured operated and are serviced and also highly value your safety and the safety of others we would like you to take the...

Страница 5: ...s situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result...

Страница 6: ...cking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can result in...

Страница 7: ...can cause a fire or explosion if ignited LPG is heavier than air and can settle in low places while dissipating LPG has a distinctive odor added to help detect potential leaks quickly In any petroleum...

Страница 8: ...anual for future reference Generator Controls and Features 1 Fuel Valve Used to turn fuel supply on and off to engine 2 Choke Used to start the engine 3 Air Filter Protects the engine by filtering dus...

Страница 9: ...operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 4 120 Volt AC 30 Amp Receptacle NEMA TT 30 May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single ph...

Страница 10: ...or ships with the following parts Wheel Kit 8 in 20 3 cm Wheel 2 Pin Roll 16 x 10 x 97 for Wheel 2 R Shape Pin 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Handle 1 Flange Bo...

Страница 11: ...wheel kit and support leg Install the Wheel Kit Install the Support Leg 1 Attach the support leg to the generator frame with flange bolts M8x16 and flange lock nuts M8 2 Tip the generator slowly so th...

Страница 12: ...ife of the bearing NOTE The recommended oil type is 10W 30 automotive oil NOTE Synthetic oil may be used after the 5 hour initial break in period Using synthetic oil does not increase the recommended...

Страница 13: ...0 pound capacity LPG tanks with Type 1 right hand Acme threads Verify the requalification date on the tank has not expired All new cylinders must be purged of air and moisture prior to filling Used cy...

Страница 14: ...lectrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional Generator Location NEVER operate the generator inside any building...

Страница 15: ...ompany power lines You are responsible for ensuring that your generator s electricity does not feed back into the electric utility power lines If the generator will be connected to a building electric...

Страница 16: ...d attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabilize 5 P...

Страница 17: ...2 threads from running out of the fill hole If using the dipstick to check oil level DO NOT screw in the dipstick while checking NOTE Engine Maintenance To prevent accidental starting remove and grou...

Страница 18: ...and muffler Check hoses for leaks First 5 Hours Change oil Every 50 hours or every season Clean air filter Change oil if operating under heavy load or in hot environments Every 100 hours or every sea...

Страница 19: ...alve on the generator to the Off position 6 The generator needs to cool completely before cleaning and storage 7 Disconnect the fuel hose from the LPG cylinder 8 Clean the generator according to the m...

Страница 20: ...ap is 0 7 0 8 mm or 0 028 0 031 in Oil Use 10W 30 automotive oil Oil capacity is up to 0 6 qt 0 6 L DO NOT OVERFILL Please reference the following chart for recommended oil types for use in the genera...

Страница 21: ...ED In W L BLACK YELLOW BLUE Br W G B W BROWN IGNITION COIL SPARKING PLUG ENGINE BLOCK B EXW FW MW1 L Y Y AVR Br 25A OIL LEVEL SW Y CONTROL BOX BLOCK Y G Y EARTH TERMINAL W W W G Y G Y G Y Y Y L L R W...

Страница 22: ...9 21 24 25 26 27 28 29 30 12 13 18 32 33 34 35 43 46 47 38 36 37 50 51 54 52 53 55 56 57 58 34 59 60 61 62 34 63 64 65 66 67 68 69 70 71 72 73 74 58 75 76 77 78 79 80 81 82 84 85 34 83 44 45 86 30 20...

Страница 23: ...t M6 x 12 9 43 122 070200 08 76 Plate 1 44 1 823 0408 Screw M4 x 8 2 45 1 93 04 Lock Washer 4 2 46 1 97 1 04 Washer 4 2 Part Number Description Qty 47 27 136000 01 Pressure Reducing Valve Assembly 1 4...

Страница 24: ...44 46 47 21 22 23 24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86 87 88 76 59 12 77 96 33 81 73 15 20 48 14 101 5...

Страница 25: ...003 00 Arm Governor 1 51 1 6177 06 Flange Nut M6 3 52 21 110001 00 Shaft Governor Arm 1 53 22 123000 01 Ignition Coil Silicon Rubber 1 54 1 5789 0625 Flange Bolt M6 25 2 Part Number Description Qty 55...

Страница 26: ...l Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air...

Страница 27: ...or is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical component Insta...

Страница 28: ...parts and labor For engines less than or equal to 80cc only the fuel tank and fuel line is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S EMISSION CON...

Страница 29: ...be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CP...

Страница 30: ...ets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of origin...

Отзывы: