201066 - 6500W OPEN FRAME INvERTER
ASSEMbLY
17
4. Place an r-clip (J) on the end of the short pin and fasten
securely.
H
J
G
I
K
Add Engine Oil
WARNING
DO NOT attempt to crank or start the engine before it has been
properly filled with the recommended type and amount of oil.
Damage to the generator as a result of failing to follow these
instructions will void your warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing
that requires no additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is
10W-30
automotive oil
. However, using the listed conventional oils
shown in the “Recommended Engine Oil Type” chart may be
used for typical use including the first 5 hours of the break-in
run time period of the engine.
If running generator in extreme temperatures, refer to the
“Recommended Engine Oil Type” chart.
-20
0
20
40
60
Ambient temperature
Recommended Engine Oil Type
80
100
120
-28.9
°F
°C
-17.8
-6.7
4.4
15.6
26.7
37.8
48.9
10W-30
5W-30 Full Synthetic
10W-40
5W-30
1. Place the generator on a flat, level surface.
2. Remove oil fill cap/dipstick to add oil.
3. Using a funnel, add up to 37.2 fl. oz. (1100 ml) of oil (included)
and replace oil fill cap/dipstick. DO NOT OVERFILL.
4. Check engine oil level at every use and add as needed.
MAX
NOTICE
Once oil has been added, a visual check should show oil about
1-2 threads from running out of the fill hole.
When using the dipstick to check oil level, DO NOT screw in
the dipstick while checking.
NOTICE
Check oil level often during the break-in period. Refer to the
Maintenance section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop
when the oil level in the crankcase falls below the threshold
level.