100868 - LOAD MANAgEMENT MODULE

IMpORTANT SAfETY INSTRUCTIONS

6

Safety and Dataplate Labels

These labels warn you of potential hazards that can cause serious injury. Read them carefully.

If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.

LABEL

DESCRIPTION

1973-L-SF-A

Electrical shock hazard. May cause injury or death. 

Disconnect all sources of supply before servicing.

Riesgo de descarga eléctrica. Puede causar 

lesión o la muerte. Desconecte todas las fuentes 

de suministro antes de realizar el servicio.

 

Risque d'électrocution. Peut causer des blessures 

ou la mort. Débranchez toutes les sources 

d'alimentation avant de procéder à l'entretien.

 DANGER

 PELIGRO

 DANGER

K

485

---

---

---

Colors

LPN

1973-L-SF

Rev

A

Size

50 x  25mm

Artwork Notes

3mm corner radius; 2mm safe margin; to be printed 

on 

WHITE substrate.

Revision Changes

---

This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for 
outside parties without the explicit consent of Champion Power Equipment.

Danger. Electrocution shock hazard.

Safety Symbols

Some of the following symbols may be used on this product. Please study them and learn their meaning. 
Proper interpretation of these symbols will allow you to more safely operate the product.

SYMBOL

MEANING

Read Operator’s Manual.

 To reduce the risk of injury, user must 

read and understand operator’s manual before using this product.

Ground.

 Consult with local electrician to determine grounding 

requirements before operation.

Electric Shock.

 Improper connections can create an electrocution 

hazard.

Содержание 100868

Страница 1: ...ns important safety precautions which should be read and understood before operating the product Failure to do so could result in serious injury This manual should remain with the product Specificatio...

Страница 2: ...y Instructions 4 Safety and Dataplate Labels 6 Safety Symbols 6 Controls and Features 7 Electrical Installation Diagram 8 Installation 9 Unpacking 9 Installing the Load Management Module LMM 9 Connect...

Страница 3: ...rt has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docum...

Страница 4: ...bligation or liability whatsoever The manufacturer cannot anticipate every possible circumstance that might involve a hazard The warnings in this manual tags and decals affixed to the unit are therefo...

Страница 5: ...tor manual section to locate aXis ENGINE CONTROL module lock out procedure CAUTION Consult with your Local municipal State and National electrical codes for proper mandatory wiring methods NOTICE Impr...

Страница 6: ...l entretien DANGER PELIGRO DANGER K 485 Colors LPN 1973 L SF Rev A Size 50 x 25mm Artwork Notes dius 2mm safe margin to be printed trate Revision Changes to Champion Power Equipment The contents are...

Страница 7: ...remote LMM turns power on and off to the load by using a Power Line Carrier PLC signal The unit is capable of controlling resistive loads up to 50 Amps when wired into the load circuit The load shoul...

Страница 8: ...100868 Load Management Module Controls and Features 8 Electrical Installation Diagram HOME PANEL METER GENERATOR UTILITY LOAD MANAGEMENT MODULE AIR CONDITIONER ATS 200 50...

Страница 9: ...nduit Pliers Fittings Wire stripper Twist on wire connectors as needed Installing the Load Management Module LMM The enclosure is NEMA type 3R rated and is suitable for indoor outdoor installations Ge...

Страница 10: ...nd L2 Line to the top of the contactor relay LINE connections 4 Connect the L1 and L2 lines to the bottom of the contactor relay LOAD connections 5 Connect the ground to the ground terminal 6 Max Torq...

Страница 11: ...are the designated ON or OFF position settings for the DIP switches DIP Switches 1 3 on LMM circuit board are used to communicate with the ATS circuit board and create a hierarchy Switches 1 2 are us...

Страница 12: ...utage 6 Return UTILITY circuit breaker to the ON position ATS will transfer load back to utility and generator will cool down and shut off 7 Repeat this process if LMM units are added or removed from...

Страница 13: ...ONS Unit Enclosure type NEMA 3R indoor outdoor Amperage 50A resistive Nominal Voltage 240VAC Height 8 2 in 208 mm Width 5 2 in 133 mm Depth 3 8 in 97 mm Torque Neutral Bar 18 10 AWG Cu9Al 35 in lb 14...

Страница 14: ...he life of a part or the equipment as a whole Installation Use and Maintenance This warranty will not apply to parts and or labor if the product is deemed to have been misused neglected involved in an...

Отзывы: