background image

3

ENGLISH

 

100331

SAFETY RULES

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death. If you start to feel dizzy or weak, get to fresh 
air immediately.

Operate generator outdoors only in a well ventilated 
area.
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings.

DANGER CARBON MONOXIDE:

 using a generator 

indoors

 CAN KILL YOU IN MINUTES

.

DANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 
Traumatic amputation or severe laceration can result.

Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught.

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use electrical cords that are worn, damaged 

or frayed.

DO NOT operate generator in wet weather.

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking.

Use approved transfer equipment to isolate generator 

from your electric utility and Notify your utility 

company before connecting your generator to your 

power system.

DANGER

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug.

DO NOT check for spark with the plug removed.

Use only approved spark plug testers.

WARNING

Running engines produce heat. Severe burns can 

occur on contact. 

Combustible material can catch fire on contact.

DO NOT touch hot surfaces.

Avoid contact with hot exhaust gases.

Allow equipment to cool before touching.

Maintain at least 3 ft. (91.4 cm) of clearance on all 

sides to ensure adequate cooling.

Maintain at least 5 ft. (1.5 m) of clearance from 

combustible materials.

WARNING

Medical and Life Support Uses.

In case of emergency, call 911 immediately.
NEVER use this product to power life support 
devices or life support appliances.
NEVER use this product to power medical devices 
or medical appliances.
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency.

WARNING

The engine exhaust from this product contains 
chemicals known to the state of California to cause 
cancer, birth defects, or other reproductive harm.

WARNING

Read this manual thoroughly before operating your 
generator. Failure to follow instructions could result 
in serious injury or death.

WARNING

Содержание 100331

Страница 1: ...UCTIONS Important safety instructions are included in this manual MADE IN CHINA REV 100331 20170908 100331 MODEL NUMBER 4500 Starting Watts 3650 Running Watts PORTABLE GENERATOR Manual Start T h ree Y...

Страница 2: ...California to cause cancer or birth defects and other reproductive harm WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer and birth defec...

Страница 3: ...the Engine 12 Do Not Overload Generator 13 Capacity 13 Power Management 13 Operation at High Altitude 13 Maintenance and Storage 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 14 Spark Arr...

Страница 4: ...the accuracy and completeness of the information in this manual and we reserve the right to change alter and or improve the product and this document at any time without prior notice Since CPE CET hi...

Страница 5: ...s situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result...

Страница 6: ...king Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can result in f...

Страница 7: ...sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements WAR...

Страница 8: ...MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell PELIGRO DANGER El uso de un generador en interiores PUEDE MATARLO EN MINUTOS El escape del generador contie...

Страница 9: ...k 2 Choke Used to start the engine 3 Fuel Valve Used to turn fuel supply on and off to engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used t...

Страница 10: ...aker 4 120 Volt AC 30 Amp Twist Lock Receptacle NEMA L5 30R May be used to supply electrical power for the operation of 120 Volt AC single phase 60 Hz electrical loads 5 120 Volt AC 30 Amp Receptacle...

Страница 11: ...rts Oil 0 6 qt 0 6 L Oil Funnel 1 Power Panel Symbols RESET The below symbols are located on the generator power panel Familiarize yourself with these symbols for quick reference of the components and...

Страница 12: ...il will aid in starting in cold ambient 5 C 41 F NOTE We consider the first 5 hours of run time to be the break in period for the unit During the break in period stay at or below 50 of the running wat...

Страница 13: ...s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1 Use clean fre...

Страница 14: ...ll become hot If adequate cooling and breathing space are not supplied or if the generator is blocked or contained temperatures can become extremely heated and may lead to fire Surge Protection Electr...

Страница 15: ...ctric utility power lines If the generator will be connected to a building electrical system consult your local utility company or a qualified electrician Connections must isolate generator power from...

Страница 16: ...rong engine configuration at a given altitude may increase its emissions and decrease fuel efficiency and performance WARNING Operation at High Altitude The density of air at high altitude is lower th...

Страница 17: ...oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spark plug cable from t...

Страница 18: ...sh 5 Replace the spark arrester if it is damaged 6 Position the spark arrester in the muffler and attach with the three screws Failure to clean the spark arrester will result in degraded engine perfor...

Страница 19: ...disconnected from the generator Long Term Storage over 1 year For storage over 1 year the fuel tank and carburetor must be completely drained of gasoline 1 Be sure all appliances are disconnected from...

Страница 20: ...must be drained and the carburetor must be thoroughly cleaned This process involves technically advanced tasks For assistance please call our Technical Support line at 1 877 338 0999 If the fuel tank...

Страница 21: ...PR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 028 0 031 in Oil Use 10 30W automotive oil Oil capacity is up to 0 6 qt 0 6 L DO NOT OVERFILL Please reference the following char...

Страница 22: ...NS Parts Diagram 1 23 24 25 26 27 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 2 3 4 5 6 7 8 9 10 11 14 15 10 16 12 17 18 44 47 48 19 20 22 21 33 13 56 57 58 59 60 61 62 64 65 66 67 68 69 70 71 72 73...

Страница 23: ...06 Lock Washer 6 4 34 1 5789 0620 1 Flange Bolt M6 x 20 Black 4 35 24 070800 00 Reversal Valve 1 36 2 06 006 Clamp 7 x 1 1 37 24 070030 00 Hole Breather Tube 1 38 122 070014 02 Pipe Reversal Valve 67...

Страница 24: ...30 32 35 37 38 12 40 41 42 43 44 46 47 21 22 23 24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86 87 88 76 59 12 7...

Страница 25: ...r 1 51 1 6177 06 Flange Nut M6 3 52 21 110001 00 Shaft Governor Arm 1 53 22 123000 01 Ignition Coil Silicon Rubber 1 54 1 5789 0625 Flange Bolt M6 x 25 2 55 23 110005 01 Spring Throttle Return 1 56 23...

Страница 26: ...G Y GREEN WHITE RED In W L BLACK YELLOW BLUE Br W G B W BROWN IGNITION COIL SPARKING PLUG ENGINE BLOCK B EXW FW MW1 L Y Y AVR Br 30A OIL LEVEL SW Y CONTROL BOX BLOCK Y G Y EARTH TERMINAL ENG SW R W W...

Страница 27: ...proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Ch...

Страница 28: ...quired to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements o rings etc A...

Страница 29: ...l system is warranted for two years subject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be r...

Страница 30: ...ement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according to Subsection d below Any such emissions related part repai...

Страница 31: ...ets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of origin...