MAINTENANCE
31
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your
warranty.
The air-fuel mixture is not adjustable. Tampering with the governor
can damage your generator and your electrical devices and
will void your warranty. Contact our Technical Support Team at
1-877-338-0999 for all other service and/or adjustment needs.
Generator battery
Your generator is equipped with an automatic battery charging
circuit that charges the battery while the engine is running.
The battery will maintain a proper charge if the unit is used on
a regular basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle charger
or battery maintainer (not included) to keep the battery properly
charged.
Maximum charging rate should not exceed 1.5 amps. Follow
the instructions included with the battery charger. The battery
should be fully charged at least once per month. If the battery is
not able to start the engine, it can be started by manually pulling
the engine recoil cord. If the battery voltage is extremely low, the
charging circuit may not be able to re-charge the battery. In this
case, the battery must be connected to a standard automotive
style battery charger for re-charging before it can be used.
Disconnect the Battery
1. Pull two halves of battery connector and replace connector
cover.
Charge the Battery
For a generator equipped with batteries for electric starting,
proper battery maintenance and storage should be followed. A
trickle charger or battery maintainer should be used to charge the
battery while the generator is in storage. Maximum charging rate
should not exceed 1.5 amps. Follow the instructions included with
the trickle charger or battery maintainer. The battery should be
fully charged at least once per month.
Remote Key fob battery
NOTICE
–
Always purchase the correct size and grade of battery
most suitable for the intended use.
–
Clean the battery contacts and also those of the device
prior to battery installation.
–
Remove batteries from equipment which is not to be used
for an extended period of time.
–
Remove batteries if consumed or if product is to be left
unused for a long time.
1. Remove the remote key fob from the key ring.
2. Remove the screw with a Phillips screwdriver (not included)
by turning counter clockwise.
3. Pry the two halves of the remote key fob apart slightly at the
key ring end.
4. Separate the two halves of the remote key fob by sliding the
back side of the remote key fob up toward the key ring end.
5. Carefully remove the circuit board to locate and replace the
CR2016 battery.
6. Reverse the above instructions to reassemble the remote key
fob.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance
schedule.
Service your generator more frequently when operating in adverse
conditions.
Contact our Technical Support Team at 1-877-338-0999 to locate
the nearest CPE certified service dealer for your generator or
engine maintenance needs.