201001 - 5500W WIRELESS REMOTE START INVERTER GENERATOR
OPERATION
26
000
0-X-
X
X-
A
ECO
CAUTION
For periods of high electrical load or momentary fluctuations,
the Eco Mode should be off.
12V DC Automotive Style Outlet
The 12V DC outlet(s) can be used with supplied accessories and
other commercially available 12V DC automotive style plugs.
Confirm the input voltage range of your item is at least 12-24V DC.
WARNING
Do not operate a device while it is plugged in to the 12V DC
outlet.
Prolonged exposure to engine exhaust can cause serious injury
or death.
WARNING
While charging a device do not place on the exhaust side of the
generator. Extreme heat caused by exhaust can damage the
device, and cause a potential fire hazard.
Battery Charging
1. Before connecting the battery charging cable (not included) to
a battery that is installed in a vehicle, disconnect the vehicle
battery ground cable from the negative (–) battery terminal.
2. Plug the battery charging cable into the 12V DC receptacle of
the generator.
3. Connect the red (+) battery charger lead to the red (+) battery
terminal.
4. Connect the black (–) battery charger lead to the black (–)
battery terminal.
5. Start the generator.
Important:
The 12V DC outlet is ONLY to be used with supplied
accessories and other commercially available 12V DC automotive
style plugs. Be sure all electric devices including the lines and
plug connections are in good condition before connection to the
generator.
WARNING
Do not start the vehicle while the battery charging cable is
connected and the generator is running. It will not give the
battery a boost of power. The vehicle or the generator may
be damaged. Charge only vented wet lead acid batteries.
Other types of batteries may burst, causing personal injury or
damage.
NOTICE
Be sure all electric devices including the lines and plug
connections are in good condition before connection to the
generator.
Parallel Operation
The Champion model 201001 is parallel ready and can be
operated in parallel with another Champion unit to increase the
total available electrical power. A Champion parallel kit (optional
equipment) is required for parallel operation. Model 100319 is the
recommended model for this unit. For a list of compatible models
or to order a parallel kit, please call customer service at 1-877-
338-0999 or visit www.championpowerequipment.com.
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator’s
manual.
Stopping the Engine
Remote Stop
1. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
2. Press the “STOP” button on the remote. The generator will
remain in standby mode for 12 hours waiting for remote input.
NOTICE
Engine will shut off but the fuel dial will remain in the “ON”
position waiting for the next start instruction.