OPERATION OF YOUR OPENER
Your opener can be activated by any of the following
devices:
• The ACTIVATION button
Press the button until door starts to move.
• The wall control, outside keylock or keyless
entry system (if you have installed any of these
accessories).
• The transmitter or wireless wall
button (CM128)
Hold the push button down until the door starts to move.
When the opener is activated by transmitter,
ACTIVATION button or wall control:
• If open, the door will close. If closed, the door will open.
• If closing, the door will stop.
• If opening, the door will stop (allowing space for entry
and exit of pets and for fresh air).
• If the door has been stopped in a partially open or
closed position, it will reverse direction.
• If an obstruction is encountered while closing, the door
will stop, then reverse.
• If an obstruction is encountered while opening, the door
will stop, reverse away from the obstruction then stop.
• The optional Protector System™ uses an invisible beam
which, when broken by an obstruction, causes a closing
door to open and prevents an open door from closing. It
is STRONGLY RECOMMENDED for homeowners with
young children.
Allow a 15 minute cooling period after 4 minutes of
continuous operation of the opener.
Opening the door manually: (refer section 8)
The door can be opened manually by pulling the release
cord down firmly.
To re-connect the door, push the red clutch lever up to
the top stop position.
The opener light will turn on:
• when the opener is initially plugged in;
• after the power has been briefly interrupted;
• when the opener is activated.
(the light turns off automatically after 2-1/2 minutes.)
MAINTENANCE OF YOUR OPENER
Once a month:
• Repeat safety reverse test.
Make any necessary adjustments (sections 13 & 14)
• Manually operate door. If it is unbalanced or binding,
call for professional garage door service.
• Check to be sure door opens and closes fully.
Set limits and/or force if necessary.
Once every 3 months:
• Ensure that mounting bolts are adequately tightened
(i.e. 25-28Nm) to the door axle.
SPECIAL NOTE: Chamberlain strongly recommends that the Protector System
TM
be installed on all garage door openers.
CARE OF YOUR OPENER
When properly installed, your opener will operate with
minimal maintenance. The opener does not require
additional lubrication.
Limit and force settings: These settings must be
checked and properly set when the opener is installed.
Weather conditions may cause some minor changes in
the door operation, requiring some re-adjustments,
particularly during the first year of operation. Refer to
limit and force setting in, sections 13 & 14.
Follow the instructions carefully and repeat the
safety reverse test after any adjustment.
transmitter:
Additional transmitters can be purchased at any time.
Refer to accessories. Any new transmitters must be
programmed into the opener.
transmitter battery:
If transmission range decreases, replace the battery.
SPECIFICATIONS MR1000
Input Voltage:
230-240VAC, 50Hz, 460W
Rated Load:
50Nm
Max.Pull Force:
700N
Max. Door Mass:
130kg (spring balanced)
Idle Current:
less than 5mA @ 230VAC
Drive:
AC gearmotor
Max. Drum Rotations:
3
Memory Registers:
64
Operating Frequency:
433.92MHz AM Peak Detect
rolling code.
Auxillary power output:
12VDC 100ma (max)
18
Door should be fully closed if possible. Weak or
broken springs could allow an open door to fall
rapidly. Property damage or serious personal injury
could result.