37
Control Board LEDs
STATUS LEDS
INPUT
POWER
OFF
OFF state
ON
AC charger or Solar power
available
BATT
CHARGING
OFF
Not charging
ON
Three stage battery charging
TIMER
OFF
The timer is disabled
ON
The timer is enabled
MEDIUM BLINK (1
blink per second)
The timer is running
FAST BLINK (2
blinks per second)
The timer is paused
FASTEST BLINK (8
blinks per second)
The timer is canceled
GATE
MOVING
OFF
The gate is stopped
ON
The gate is opening or closing
MEDIUM BLINK (1
blink per second)
Operator is in E1 (single
entrapment)
FASTEST BLINK (8
blinks per second)
The operator is in E2 (double
entrapment)
BATT LOW
OFF
No battery error
ON
Battery low
MEDIUM BLINK (1
blink per second)
Battery critically low
ACC PWR
OVLD
OFF
OFF state
ON
Accessory overload protector
opened
INPUT LEDS
SBC INPUT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
FIRE DEPT INPUT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
EXIT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
SHADOW
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
CLOSE
EYES/INTERRUPT
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
CLOSE EDGE
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
OPEN EYES/EDGE
OFF
Input inactive
ON
Input active
BLINK
Input active on other operator
LOCK
OFF
Maglock relay inactive
ON
Maglock relay active
TROUBLESHOOTING