4
OL
A1
13
5
3
1
A2
14
6
4
2
A1
13
5
3
1
A2
14
6
4
2
L1
L2
G
11
10
9
8
7
6
5
4
3
2
1
A1
4
A1
1
2
L/S “A” NC
C
L/S “B” NC
C
(TB2)
1
3
8
5
4
2
OL
4
5 2 3
8
1
TB1-5
R4
TB2-AB
TB2-CD
TB1-8
TB1-3
TB2-AB
TB2-CD
4
6
7
8
9
10
4
6
7
8
9
10
TB1-15
TB1-3
R1
R2
R3
R4
TB1-6
1
2
3
4
5 6
7
8
9
10
12 13 14 15 16 17 18 19 20
11
R1
RADIO
SHADO
W
VDC COM
CLOSE
ST
OP
SOFT OPEN
HARD OPEN
INTERR
UPT OPEN CLOSE
EDGE/PHOTO
EYE
MASTER
SECOND
MAGLOCK
24 VAC ACCESSORY
POWER INTERRUPT
LOOP
EXIT LOOP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
J1
J4
1 2
J2
TB1-20
TB1-19
TB1-18
TB1-17
AB
CD
(TB1)
TB2-CD
To protect against fire and electrocution:
• DISCONNECT power BEFORE installing or servicing operator.
• Replace ONLY with fuse of same type and rating. Fuse: 3AG, 3.2A, 120V, SLO-BLO
NOTES:
1. Voltage: 115, 208 & 230 volt - 1 phase.
2. Horsepower 1/2 & 1 HP.
3. Transformer primary voltage is the same as the
operator voltage. Secondary 24v/60va.
For reference primary wire colors: 120v black,
208v red, 230v orange, 460v purple, 575v grey.
4. Terminal designations shown for 115v.
5. Terminal block in limit switch enclosure (SL595 only).
6. For single phase 115v operation, there is an additional white
wire from contactor A2 to contactor B4 and the black wire from the transformer to contactor B4 goes to B6.
7. When using a remote control or single button control station in lieu of the soft open feature, perform the following modifications to the operator:
• Remove the green wire from R4 of the radio block and mount the wire to terminal block TB1 position 6.
• Move the brown wire on terminal block TB1 position 6 (from radio block R4) to terminal block TB1 position 1.
CONTACTOR A & B
CONTACTOR
208/230V SHOWN
SEE NOTE 6
POWER IN
SEE NOTE 1
J2 PLUG
ON PCB
OVERLOAD
RPM
BOARD
Black
Red
White
Orange
Purple
Green
Purple
GROUND
CONTACTOR A
CONTACTOR B
Orange
Purple
115V. BRAKE SOLENOID
115V CONNECTION
230V. BRAKE SOLENOID
208/230V CONNECTION
LOOP WIRING
FREE EXIT
LOOP
HARNESS
(10 PIN)
INTERRUPT
LOOP
HARNESS
(10 PIN)
ALARM
RADIO
TERMINAL
BLOCK
Blue
Black
Brown
Green
SEE NOTE 7
SEE NOTE 5
MOTOR
OVERLOAD
LOAD
24VAC/60VA
FUSE 3.2A
SERVICE OUTLET
(115V) ONLY
ON/OFF
SWITCH
LINE
LINE
SEE NOTE 5
SEE NOTE 5
SEE NOTE 3
SEE NOTE 7
FACTORY
INSTALLED
RADIO
Purple
RESET
STOP
Green
Brown
Orange
Green
Gray
Black
Black
White
Red
Blue
OPEN
CLOSE
STOP
RESET
FIELD CONNECTIONS
(GL CONTROL BOARD)
24 VAC
RADIO
SIGNAL
Black
Black
Blue/Black
Blue/Black
Blue/Black
Blue/Black
Black
Black
Black
Black
Black
Black
Black
Black
Blue
Blue
Blue
Yellow/Black
Yellow/Black
Yellow/Black
Yellow/
Black
Yellow/
Black
Yellow/
Black
Yellow/Black
Yellow/Black
Yellow/Black
Yellow/Black
Green
Green
Yellow
Yellow
Yellow
Purple/White
Purple
Red
White
White
White
White
Orange
Orange
Orange/Black
Black
Gray
Blue
Yellow
Purple
Gray
Yellow
Blue
Yellow
Yellow
Blue
Yellow
Gray (SL595 Green)
Yellow (SL595 White)
Black (SL595 Orange)
Purple (SL595 Red)
TO J2-1
TO J2-1
TO MOTOR
(100db)
SAFETY
ALARM
(TB1)
Orange
Purple
SINGLE PHASE WIRING DIAGRAM