DIAGRAMA DE CABLEADO MONOFÁSICO

OL

A1 
13 



A2 
14 



A1 
13 



A2 
14 



L1 
L2 

11

10

9

8

7

6

5

4

3

2

1

A1 

4

A1 

1

2

L/S “A” NC 

L/S “B” NC 

(TB2)

1

3

8

5

4

2

OL 

4

5 2 3

8

1

TB1-5 

R4

TB2-AB 

TB2-CD 

TB1-8 
TB1-3 

TB2-AB 

TB2-CD 





10 





10 

TB1-15

TB1-3

R1 

R2 

R3 

R4 

TB1-6

1

2

3

4

5 6

7

8

9

10

12 13 14 15 16 17 18 19 20

11

R1 

RADIO 

SHADO

VDC COM 

CLOSE 

ST

OP 

SOFT OPEN 

HARD OPEN 

INTERR

UPT  OPEN    CLOSE 

EDGE/PHOTO 

EYE 

MASTER  

SECOND 

MAGLOCK 

24 VAC ACCESSORY 

POWER     INTERRUPT 

LOOP 

EXIT LOOP 

1    2     3     4    5    6     7     8    9   10   11  12   13  14   15   16 

J1 

J4 

1    2 

J2 

TB1-20 
TB1-19 

TB1-18 
TB1-17 

AB

CD

(TB1)

TB2-CD

Para proteger contra incendios y electrocución:

• DESCONECTAR la alimentación eléctrica ANTES de instalar el operador o hacer

  mantenimiento.

• Reemplace SOLO con fusibles del mismo tipo y capacidad.

  Fusible: 3AG, 3.2A, 120V, SLO-BLO   

CONTACTOR A y B

CONTACTEUR

SE MUESTRA PARA 

208/230 V

VEA NOTA 6 

ENTRADA DE 

ALIMENTACIÓN 

VEA NOTA 1 

FICHA J2 EN 

LA TARJETA

SOBRECARGA

SENSOR

DE RPM

CONTACTOR A

CONTACTOR B

CONEXIÓN DEL CIRCUITO DETECTOR

ARNÉS DEL 

BUCLE DE 

SALIDA LIBRE  

(10 CLAVIJAS)

ARNÉS DEL 

BUCLE DE 

INTERRUPCIÓN 

(10 CLAVIJAS)

ALARMA

BLOQUE DE 

TERMINALES 

DE RADIO

VEA NOTA 7

VEA NOTA 5

SOBRECARGA 

DEL MOTOR 

CARGA 

24 VCA/60 VA

FUSIBLE

3.2A

SALIDA DE SERVICIO

(115 V) ÚNICAMENTE

INTERRUPTOR DE 

ACTIVADO/

DESACTIVADO

LÍNEA

LÍNEA

VEA NOTA 5

VEA NOTA 5

VEA NOTA 3

VEA NOTA 7

RADIO 

INSTALADA 

EN FÁBRICA

REINICIO

PARAR

PARAR

REINICIO

CABLEADO DE CAMPO

(TARJETA DE CONTROL DE GL)

AL J2-1

AL J2-1

AL MOTOR

ALARMA DE 

SEGURIDAD 

(100 db)

Negro (SL595 Naranja)

Negro

Negro/Azul

Negro/Azul

Negro/Azul

Negro/Azul

Amarillo/Negro

Amarillo/Negro

Amarillo/Negro

Amarillo/Negro

Amarillo/Negro

Amarillo/Negro

Amarillo/Negro

Amarillo/

Negro

Amarillo/

Negro

Amarillo/

Negro

Verde

Verde

Verde

Verde

Verde

Verde

Gris

Gris

Gris

Gris (SL595 Verde)

Amarillo (SL595 Blanco)

Amarillo

Amarillo

Amarillo

Amarillo

Amarillo

Amarillo

Amarillo

Amarillo

Púrpura

Púrpura

Púrpura

Púrpura

Púrpura

Púrpura

Púrpura

Púrpura (SL595 Rojo)

Rojo

Rojo

Blanco

Blanco

Blanco

Blanco

Blanco

Blanco

Naranja

Naranja

Naranja

Naranja

Naranja

Naranja

Naranja/Negro

Rojo

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Negro

Azul

Azul

Azul

Azul

Azul

Azul

Azul

Azul

Marrón

Marrón

Púrpura/Blanco

TIERRA

NOTAS:

1. Voltaje: 115, 208 y 230 Voltios - Monofásico.

2. Potencia de 1/2 y 1 HP.

3. El voltaje del primario del transformador es igual 

    voltaje del operador. Secundario de 24 V/60 VA. 

    Colores de los cables del primario: 120 V, negro; 

    208 V, rojo; 230 V, anaranjado; 460 V, violeta; 

    575 V, gris.

4. Los terminales indicados corresponden a 115 V. 

5.       Bornera en el alojamiento del límite de carrera (SL595 únicamente). 

6. En operadores monofásicos de 115 V hay un cable blanco adicional desde el contactor A2 al contactor B4 y el cable negro desde el transformador hasta el contactor B4 está conectado a B6. 

7. Al usar el control remoto o el botón del comando fijo en lugar de la función de software realizar las siguientes modificaciones al operador: 

  • Desconectar el cable verde del terminal R4 de la bornera de comunicaciones y conectarlo al terminal 6 de la bornera TB1. 

  • Conectar el cable marrón del terminal 6 de la bornera TB1 (en la bornera R4 de comunicaciones) al terminal 1 de bornera TB1.

 

24 Vca 

SEÑAL

DE 

RADIO 

APERTURA

CIERRE

SOLENOIDE DE  FRENO, 230V

SOLENOIDE DE  FRENO, 115V

CONEXCIÓN DE 

MOTOR DE 115 V

CONEXCIÓN DE 

MOTOR DE 208V/230 V

Содержание K29-32410

Страница 1: ...J1 TERMINAL BLOCK Red wire from alarm Main board Black wire from alarm Alarm Plastic nut Flange Regulator Old alarm Flange Operator chassis Plastic nut CARTON INVENTORY Alarm with wire harness 1 Extra blue wire stripped on both sides connects J1 3 to J1 15 1 Wire ties 4 Flange 41 G0538 1 TOOLS NEEDED Pliers 2 Phillips Head screwdriver 1 8 flat Phillips Head screwdriver Diagonal wire cutters Wire s...

Страница 2: ...ange Figure 3 a Remove the plastic nut from the alarm b Insert the alarm through the flange c Secure the alarm to the flange with the plastic nut 3 Use a provided wire tie to secure the wires from the alarm to the body of the alarm as shown to prevent the wires from being tangled in the sprocket 4 Route the wire harness to the main board following the same path as the old harness Connect the red w...

Страница 3: ... White White White White White White White White Orange Orange Orange Orange Black Black Blue Brown Brown Gray Brown Gray Brown Yellow Black Yellow Black Yellow Green Green Gray Gray Gray Purple White Purple Black Black Blue Red White White White Orange Orange Black Brown Brown Brown NOTES 1 Transformer primary voltage same as operator line voltage 24V secondary 60VA 2 Wire color 115V black 208V r...

Страница 4: ...g modifications to the operator Remove the green wire from R4 of the radio block and mount the wire to terminal block TB1 position 6 Move the brown wire on terminal block TB1 position 6 from radio block R4 to terminal block TB1 position 1 CONTACTOR A B CONTACTOR 208 230V SHOWN SEE NOTE 6 POWER IN SEE NOTE 1 J2 PLUG ON PCB OVERLOAD RPM BOARD Black Red White Orange Purple Green Purple GROUND CONTACT...

Страница 5: ...uímicos incluido el plomo que a consideración del estado de California causan cáncer defectos congénitos u otros daños reproductivos Para más información visite www P65Warnings ca gov CONTENIDO DE LA CAJA Alarma con arnés de cableado 1 Cable extra azul pelado en ambos lados conecta J1 3 a J1 15 1 Bridas para cables 4 Brida 41 G0538 1 HERRAMIENTAS NECESARIAS Pinzas Destornillador Phillips núm 2 Des...

Страница 6: ...ire la tuerca de plástico de la alarma b Inserte la alarma a través de la brida c Asegure la alarma a la brida con la tuerca de plástico 3 Use una brida para cables suministrada para asegurar los cables de la alarma al cuerpo de la alarma como se muestra para evitar que los cables se enreden en la rueda dentada 4 Tienda el arnés de cableado al tablero principal siguiendo la misma ruta que el arnés...

Страница 7: ... cable marrón del terminal 6 de la bornera TB1 en la bornera R4 de comunicaciones al terminal 1 de bornera TB1 BLOQUE DE TERMINALES EN CERRAMIENTO DE INTERRUPTOR LIMITADOR SÓLO SL595 ENTRADA DE ALIMENTACIÓN MONOFÁSICA 115V SOLAMENTE 208 230V SOLAMENTE 24 Vca SEÑAL DE RADIO BLOQUE DE RADIO RADIO INSTALADA EN FÁBRICA CONEXCIÓN DE MOTOR DE 115 V CONEXCIÓN DE MOTOR DE 208V 230 V 115V SOLAMENTE VEA NOT...

Страница 8: ... Amarillo Negro Amarillo Negro Amarillo Negro Amarillo Negro Amarillo Negro Amarillo Negro Amarillo Negro Amarillo Negro Amarillo Negro Amarillo Negro Verde Verde Verde Verde Verde Verde Gris Gris Gris Gris SL595 Verde Amarillo SL595 Blanco Amarillo Amarillo Amarillo Amarillo Amarillo Amarillo Amarillo Amarillo Púrpura Púrpura Púrpura Púrpura Púrpura Púrpura Púrpura Púrpura SL595 Rojo Rojo Rojo Bl...

Страница 9: ...rre fils 4 Bride 41 G0538 1 OUTILS NÉCESSAIRES Pinces Tournevis à tête cruciforme no 2 Tournevis à tête plate 1 8 po Coupe fils diagonaux Pince à dénuder Components covered with heat shrink Removable connector AC ALARM DC ALARM ENLEVER L ALARME C C EXISTANTE 1 Déconnecter l alimentation à l actionneur 2 Déconnecter le faisceau de fils des connexions J1 16 et J1 12 de la carte principale Figure 1 R...

Страница 10: ... alarme 2 Monter l alarme dans la bride Figure 3 a Déposer l écrou de plastique de l alarme b Insérer l alarme dans la bride c Fixer l alarme à la bride avec l écrou de plastique 3 Utiliser l un des serre fils fournis pour fixer les fils de l alarme au corps de l alarme comme montré afin d empêcher les fils de s emmêler dans le pignon 4 Acheminer le faisceau de fils neuf au tableau principal en su...

Страница 11: ...vert de la borne R4 du bloc radio et raccordez le à la position 6 du bornier TB1 2 Déplacez le fil brun de la position 6 du bornier TB1 venant du bloc radio R4 à la position 1 du bornier TB1 BLOC DE CONNEXION DANS LE BOÎTIER DE L INTERRUPTEUR DE FIN DE COURSE SL595 UNIQUEMENT ENTRÉE ALIMENTATION PHASE 1 COMMUTATEUR MARCHE ARRÊT 115V SEULEMENT 115V SEULEMENT 208 230V SEULEMENT 24 V c a SIGNAL RADIO...

Страница 12: ...5 Blanc Gris SL595 Vert Noir Bleu Noir Bleu Noir Bleu Noir Bleu Juane Noir Juane Noir Juane Noir Juane Noir Juane Noir Juane Noir Juane Noir Juane Noir Juane Noir Juane Noir Vert Vert Vert Vert Vert Vert Gris Gris Gris Juane Juane Juane Juane Mauve Blanc Mauve Mauve Mauve Mauve Mauve Mauve Mauve Rouge Rouge Orange Orange Orange Orange Orange Orange Rouge Noir Noir Noir Noir Noir Noir Noir Noir Noi...

Отзывы: