![Challenge CMT 330 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/challenge/cmt-330/cmt-330_installation-and-operators-manual_2586082048.webp)
APR 2018
CMT-330 Three Knife Trimmer
3-12
3. Operator's Guide
Status Messages Continued
Message
Description
S - k n i f e l a t c h e r r o r O F F
w h e n i t s h o u l d b e O N
The side knife latch proximity did not activate. This can be caused by a faulty or misad-
justed proximity sensor. The air cylinder may have failed to pull in.
S - k n i f e l a t c h e r r o r O N
w h e n i t s h o u l d b e O F F
The side knife latch proximity sensor did not de-activate. This can be caused be a faulty
sensor. The air cylinder may have failed to extend.
S - K n i f e a t d o w n l i m i t
F a i l e d t o m o v e
This error message displays when the side knives do not leave the down proximity switch.
Either the cut valve did not de-energize, or the down limit proximity sensor may be faulty.
S e r i a l C o m m u n i c a t i o n
P o r t F a i l e d
The external control port is not working properly.
S e r i a l e r r o r n o r e -
s p o n s e f r o m t h e s e r v o -
m o t o r
The servo control port is not working properly.
S e r v o P o r t F a i l e d
RS-232 port controlling the servo drive failed.
S e r v o R e l a y E r r o r ! O N
w h e n i t s h o u l d b e o f f
Output 11 is off and input 23 is on.
S e r v o R e l a y E r r o r ! O F F
w h e n i t s h o u l d b e o n
Output 11 is on and input 23 is off.
S - K n i f e a t u p l i m i t ,
F a i l e d t o m o v e
This message is displayed when the side knives do not leave the up proximity sensor.
There are at least four reasons for this failure: the dump valve did not energize, the propor-
tional valve did not energize, the knife down valve did not energize, or the side knife up
proximity sensor is faulty.
S - K n i f e d o w n F A I L U R E
t i m e d o u t b e f o r e r e a c h -
i n g d o w n l i m i t
This message is displayed when the side knives leave the up limit but do not reach the
down limit in time. If the knives did come down, the proximity sensor may be faulty or mis-
adjusted. If the knives only moved down slightly, either the unload valve or the proportional
valve may not have energized.
S t a r t B u t t o n H e l d i n a t
p o w e r u p
Either the start button or remote cut button is being held in. Either button may be faulty.
S - K n i f e u p F A I L U R E
t i m e d o u t b e f o r e r e a c h -
i n g u p l i m i t
This message displayed when the side knives do not reach the up limit in time. Either a
faulty or misadjusted up proximity sensor may cause this error.
S - S l o w d o w n F a i l u r e
The slow down proximity did not respond before the down proximity sensor. Either a faulty
or misadjust side knife slow down proximity sensor may cause this error.
S t o p b u t t o n p r e s s e d
Either a stop button is pressed or one is faulty.
U p p e r d o o r i s O p e n
One of the upper doors is open.
Содержание CMT 330
Страница 4: ...APR 2018 CMT 330 Three Knife Trimmer iv Introduction Notes...
Страница 9: ...APR 2018 CMT 330 Three Knife Trimmer 1 5 1 Introduction 1 6 Packing List...
Страница 26: ...APR 2018 CMT 330 Three Knife Trimmer 1 22 1 Introduction Notes...
Страница 36: ...APR 2018 CMT 330 Three Knife Trimmer 2 10 2 Installation Guide Notes...
Страница 52: ...APR 2018 CMT 330 Three Knife Trimmer 3 16 3 Operator s Guide Notes...
Страница 67: ...APR 2018 CMT 330 Three Knife Trimmer 5 5 5 Book Quality Notes...