Ρύθμιση
Settings
PIGMA/PIGMA SYSTEM
Checking slow ignition power
The soft light can be adjusted between the maximum power and
the minimum power.
The display shows the value between “0” and “100” of this interval.
Change the parameter if the outlet pressure from the gas valve in
the ignition phase (measured when the boiler is in hot water heating
operation) does not coincide with the values shown in the Gas Table.
To check the slow ignition power, access menu 2/sub menu 2/
parameter 0.
If needed, change the parameter value until suitable pressure is
achieved.
Heating ignition delay adjustment
This parameter – menu 2/sub menu 3/parameter 5 - can be used
to manually (0) or automatically (1) set the delay time before the
subsequent reignition of the burner after it has switched off on
reaching the desired temperature.
By selecting manual, it is possible to set the delay in minutes using
the successive parameter (menu 2/sub menu 3/parameter 6), to a
time between 0 and 7 minutes.
Automatic selection means that the boiler will establish the delay
time based on the set-point temperature.
Maximun Heating Power adjustment
The maximum heating power can be adjusted to between the maxi-
mum power allowed by the boiler and the minimum power).
The display shows the value between “0” and “100” of this interval.
To check the maximum heating power, access menu 2/sub menu 3/
parameter 1, check the value and, if necessary, modify it as indicated
in the Gas Pressure table.
Έλεγχος ελάχιστης ισχύος
1. Για να ελέγξετε την ελάχιστη ισχύ, λασκάρετε τη βίδα 2 (εικ. b) και
συνδέστε το σωλήνα του μανόμετρου στην παροχή πίεσης..
2. Αποσυνδέστε το σωληνάκι αντιστάθμισης του θαλάμου αέρα.
3. Θέστε το λέβητα σε λειτουργία στη μέγιστη ισχύ
(ενεργοποιώντας τη «λειτουργία καθαρισμού
καπνοδόχου».
Πιέστε το κουμπί RESET για 10 δευτερόλεπτα,
στην οθόνη εμφανίζεται το TEST και η εικόνα
Ο λέβητας οδηγείται στη μέγιστη ισχύ
θέρμανσης.
Γυρίστε τον επιλογέα
(4)
για να επιλέξετε την
εικόνα
και
. Ο λέβητας οδηγείται στην
ελάχιστη ισχύ.
Αποσυνδέστε ένα καλώδιο του ρυθμιστή (εικ. d). Η πίεση τροφοδοσίας
πρέπει να αντιστοιχεί στην τιμή που αναγράφεται στον πίνακα
«Ρύθμιση αερίου» για τον τύπο αερίου με τον οποίο λειτουργεί ο
λέβητας. Εάν διαφέρει γυρίστε τη βίδα ρύθμισης 4 (εικ. d).
4. Στο τέλος του ελέγχου σφίξτε τη βίδα 2 και ελέγξτε τη στεγανότητά της.
5. Συνδέστε το καλώδιο του ρυθμιστή.
6. Συνδέστε πάλι το σωληνάκι αντιστάθμισης.
7. Η λειτουργία καθαρισμού καμινάδας διακόπτεται αυτομάτως μετά
από 10 λεπτά ή πιέζοντας το πλήκτρο RESET.
Checking the minimum power
1. To check the minimum power level, loosen screw “2” (Fig. b) and
insert the pressure gauge connection pipe into the pipe tap.
2. Disconnect the air chamber compensation tube.
3. Switch the boiler on at maximum power, enabling
the “fl ue sweep” function.
Press the RESETbutton for 10 seconds, on the display
appear
TEST
and the icon
. The boiler is foced to
the maximum heating power. Rotate the encoder
(4)
to select the icon
and
.
The boiler is forced to the minimum power.
Disconnect a wire from the modulator (fi g. d); the
supply pressure should correspond to the value
shown in the “Gas Settings” table, in relation to the type of gas for
which the boiler is designed. If it does not correspond, tighten or
loosen the adjustment screw “4” (fi g. d).
4. When the check is over, tighten screw “2” and make sure it is
securely in place.
5. Reconnect the modulator wire.
6. Reconnect the compensation tube.
7. The “fl ue sweep function” is automatically deactivated after 10
minutes or when the RESET button is pressed.
Έλεγχος ισχύος αργής ανάφλεξης
Η αργή ανάφλεξη μπορεί να ρυθμιστεί ανάμεσα στην μέγιστη και
ελάχιστη ισχύ. Η οθόνη δείχνει την τιμή ανάμεσα στο “0” και το “100”.
Η παράμετρος πρέπει να τροποποιηθεί εάν η πίεση στην έξοδο της
βαλβίδας αερίου σε φάση ανάφλεξης (με το λέβητα σε λειτουργία
παραγωγής ζεστού νερού) δεν συμπίπτει με τις τιμές στον Πίνακα
αερίου.
Για να ελέγξετε την ισχύ αργής ανάφλεξης επιλέξτε το μενού 2/
υπομενού 2/παράμετρος 0.
Εν ανάγκη αλλάξτε την τιμή της παραμέτρου έως ότου επιτευχθεί η
σωστή πίεση.
Ρύθμιση καθυστέρησης ανάφλεξης θέρμανσης
Η παράμετρος αυτή - μενού 2/υπομενού 3/παράμετρος 5 - επιτρέπει
,τη χειροκίνητη (0) ή αυτόματη (1) ρύθμιση του χρόνου αναμονής
πριν το επόμενο άναμμα του καυστήρα μετά το σβήσιμο από την
επέμβαση του θερμοστάτη.
Επιλέγοντας τη χειροκίνητη ρύθμιση μπορείτε να προγραμματίσετε
την καθυστέρηση σε λεπτά με την επόμενη παράμετρο (μενού 2/
υπομενού 3/παράμετρος 6) από 0 έως 7 λεπτά.
Επιλέγοντας την αυτόματη ρύθμιση ο λέβητας καθορίζει τον χρόνο
καθυστέρησης αναλόγως με την επιλεγμένη θερμοκρασία.
Ρύθμιση της Μέγιστης Ισχύος Θέρμανσης
Η μέγιστη ισχύς θέρμανσης μπορεί να ρυθμιστεί ανάμεσα στην
μέγιστη ισχύ που επιτρέπεται απο τον λέβητα και στην ελάχιστη ισχύ.
Η οθόνη δείχνει την τιμή ανάμεσα στο “0” και το “100”. Για να ελέγξετε
την μέγιστη ισχύ θέρμανσης, μπείτε στο μενού 2/υπομενού 3/
παράμετρος 1, ελέξγτε την τιμή και , αν είναι απαραίτητο μεταβάλλετε
την όπως επισημαίνεται στο Πίνακα Πιέσεων Αερίου.