Optional Master media
OMEGA ACTIVE Programming Instructions
33
RELEASE-MASTER
With the RELEASE-MASTER, you can set locking cylinders,
shields or wall terminals into enable condition. In enable
condition, no locking media are read and the locking devices
are permanently open.
The cylinder or shield allows permanent access.
The relay of the wall terminal is permanently pulled up.
To set the enable condition:
Rotate the outside knob of the locking cylinder by at least
one notch or touch the proximity sensor.
Hold the RELEASE-MASTER for about two seconds in front of
your locking device (Confirmation: 1 x short signal).
Deactivate enable condition:
Rotate the outside knob of the locking cylinder by at least
one notch or touch the proximity sensor.
Hold the RELEASE-MASTER for about five seconds in front of
your locking device (Confirmation: 2 x short signal).
In response, your locking cylinder uncouples and/or the relay
of the wall terminal drops. The enable condition is also
terminated when you hold the BLOCK-MASTER in front of your
locking cylinder or wall terminal as described below.