background image

CES OMEGA FLEX

Update-Terminals

Update-Terminal

Assembly and Operating Instructions

English

Version VA

BRO2269

-2

Содержание OMEGA FLEX

Страница 1: ...CES OMEGA FLEX Update Terminals Update Terminal Assembly and Operating Instructions English Version VA BRO2269 2...

Страница 2: ...d in the OMEGA FLEX 8 5 Update Terminal basics 12 5 1 About the Update Terminal 12 5 2 About the validation of locking media 12 5 3 About the validity of the locking media 12 5 4 About the blocking of...

Страница 3: ...ing the online mode of an Update Terminal 30 7 8 Checking quality of wireless connection 31 7 9 Authorising an RF Stick Master 33 7 10 Deleting System Master 35 8 Operation 36 8 1 Programming Locking...

Страница 4: ...e of the product are presumed for the use of this manual The necessary product training is conducted by your CES partner In case it has not yet been done please contact your CES partner to get the pro...

Страница 5: ...contact your CES partner 1 5 Notes on trademark protection MIFARE MIFARE classic MIFARE Ultralight and MIFARE DESFire are registered trademarks of NXP B V and are used under license Update Terminal Pa...

Страница 6: ...false operation l Damages caused by overvoltage l Damages caused by fire water or smoke All technical data and features are subject to change without prior notice All information and data contained in...

Страница 7: ...3 CE Declaration of conformity The Declaration of Conformity is available online via www ces eu Update Terminal Page 7 of 41 3 CE Declaration of conformity...

Страница 8: ...ystem instead of a mechanical locking cylinder Thereupon the doors can be opened with an authorised locking media e g with a key fob or an identity card which contains a transponder If an authorised l...

Страница 9: ...ble as mechanical locking device Long shield MLS This allows you to combine the electronic and mechanical handle sets with each other in a uniform design 4 3 2 Locking media The locking media can open...

Страница 10: ...Net themselves Key Point Update Terminals no locking device function Wall terminals Wall terminal variant VA no programming function 4 3 5 Variants of OMEGA FLEX locking devices The different variant...

Страница 11: ...ne VA Validation Validation function wireless online network time profiles and events available RF Stick and Access Point Online Availability of variants for different locking devices Variant Electron...

Страница 12: ...ing media are usable Wall terminals and Update Terminals are connected to the OMEGA Server via wireless online network Key Points via LAN This enables all validation devices to read all events stored...

Страница 13: ...eated after the validity has expired If a wireless online network is used the programming jobs are automatically transmitted to the locking devices The validity is set via the CEStronics Suite A detai...

Страница 14: ...e 2 1 Update Terminal Consisting of cover and controller 3 2 Universal screws 2 5 x 20 mm 4 2 Dowel for fixing screws 5 2 Fixing screws 3 x 30 mm 6 2 Parts description 1 Shield 2 Controller 3 Assembli...

Страница 15: ...for relay no function 3 Connections for power supply 4 Screw terminals from controller to reader not required for WT I and Update Terminal 6 4 Wiring 1 Screw terminal for power supply 12 24 V AC DC 2...

Страница 16: ...bis 9 mm Slot width Lifting the cover Slot head screwdriver PZ1 Screwing the universal screws Screwing the fixing screws in case you use the delivered ones Drill depends on the mounting surface Drill...

Страница 17: ...rminal consisting of CONTROLLER and COVER in your hands 2 Loosen the COVER by setting the slot head screwdriver 5 mm to 9 mm slit width in the recess in the cover and lift it gently 3 Remove the COVER...

Страница 18: ...les of the controller are positioned horizontally For both mounting options ensure that all cables required for the connection are present and have been guided through the mounting frame or the switch...

Страница 19: ...electricians or by specialists trained by CES partner 3 Screw the CONTROLLER with two UNIVERSAL SCREWS on the mounting frame or on the switch box While assembling make sure that the LEDs 1 are positi...

Страница 20: ...5 Push the COVER on the CONTROLLER until it snaps in audibly The Update Terminal is now assembled Page 20 of 41 Update Terminal 6 Assembly...

Страница 21: ...ollowing administration devices and master media l PC with OMEGA Client installed l Access Point s l System Master l RF Ini Master Basic procedure for administration via V Net 1 You build a wireless o...

Страница 22: ...rminal via an RF Stick 2 Make sure that the Update Terminal is close to an Access Point and activate the online mode of the Update Terminal The Access Point must have the same radio cell as the Update...

Страница 23: ...nd then remove it from the reading field The following signal appears 1x short green and 1x short beep 2 Hold the System Master for ca 1 second in the reading field of the Update Terminal and then rem...

Страница 24: ...king device Since at any given time only one System Master exists which can be authorised on the basis of individual system identification code for a locking device there is reason to suspect manipula...

Страница 25: ...cedure 1 Hold the System Master for ca 1 second in the reading field of the Update Terminal to end the authorise master media mode The following signal appears 1x short green and 1x short beep 2 Hold...

Страница 26: ...orisations remain stored The RF Stick Master is now authorised for the Update Terminal Troubleshooting Signalling Reason Solution During step 2 The master media could be read but could not be authoris...

Страница 27: ...ck l PC with OMEGA Client installed Procedure 1 Proceed with your PC and the RF Stick connected to it to the Update Terminal into which you want to transmit the radio cell settings 2 Hold the RF Stick...

Страница 28: ...d the Update Terminal are disconnected automatically The programming job transmission is complete when the Update Terminal signals 1x long green and 1x long beep Troubleshooting Signalling Reason Solu...

Страница 29: ...green and 1x short beep successfully connected to the Access Point B 1x long red and 1x long beep no connection to the Access Point possible C 1x long green and 1x long beep Connection to the Access P...

Страница 30: ...necessary to authorise the RF Ini Master in advance Procedure 1 Hold the RF Ini Master for ca two seconds in the reading field of the Update Terminal The following signal appears 2x short green and 2x...

Страница 31: ...RF Trace Master is ready for immediate use and does not have to authorised first Procedure 1 Hold the RF Trace Master for ca 1 second in the reading field of the Update Terminal The following signal...

Страница 32: ...wireless connection with the same signalling as the locking device 3 Hold the RF Trace Master ca 1 second in the reading field to end the wireless connection quality display The following signal appe...

Страница 33: ...ice The following signal appears 1x short green and 1x short beep 2 Hold the RF Stick Master for ca 5 second in the reading field of the Update Terminal The following signal appears 2x short green and...

Страница 34: ...RF Stick Master is now not authorised for the Update Terminal any more Troubleshooting Signalling Reason Solution During step 2 The master media was held too short in the reading field of the Update...

Страница 35: ...ystem Master Procedure 1 Hold the System Master for ca 5 seconds in the reading field of the Update Terminal The following signal appears 2x short green and 2x short beep 2 Remove the System Master fr...

Страница 36: ...media in the reading field Only V NET locking media can be used with Update Terminals The locking media has been blocked or is not valid any more Locked or invalid locking media cannot be used Contact...

Страница 37: ...ve held a LINE locking media in the reading field Only V NET locking media can be used with Update Terminals The locking media has been blocked or is not valid any more Locked or invalid locking media...

Страница 38: ...r way for the disposal of the device and its constituent parts Package The packagings of the OMEGA FLEX components are made of environmentally friendly reusable materials Specifically these are l Oute...

Страница 39: ...tration device 10 C Coupled 8 D Decoupled 8 L Locking device 8 9 Variants 10 Locking media 8 9 O OMEGA FLEX system 8 Opening duration 8 T Target group of the manual 4 Transponder 8 Update Terminal Pag...

Страница 40: ...V Validation 12 Validity 12 Variants locking devices 10 changing 11 Page40 of 41 Update Terminal 10 Index...

Страница 41: ...Sfrance SARL 8 Impasse Charles Petit F 75011 Paris 33 1 44 87 07 56 33 1 43 07 35 78 info fr ces eu Austria C sar A C rcamo B ro Wiener Bundesstrasse 33 A 4050 Traun 43 660 73 20 311 43 732 21 00 22 2...