SmaRT BU-xH6R
U078.2.3-SmaRTxH6R_BU-R
22
C4: BU-xH6R/PG Remote Communication
Caution
To prevent inadvertent machine movement, be sure to
remove power from the Base Unit before attempting to
Associate or Dissociate.
To Associate (See Figure 12).
The PG remote must be OFF, and the base unit must have power removed before starting the
Association process.
Note: The Machine Stop button must be in the UP position before activating and using the
console remote.
1. Stand near the base unit with the remote
OFF
and
power removed
from the
base unit (disconnect the P1 and P2 cables or turn the source power OFF).
2. Release the
STOP
button on the PG handheld by twisting and pulling it up.
3. Push and hold switches
SW1
and
SW7 UP
. All four LEDs light solid.
4. Observe the LEDs. When TX begins to blink, power up the base unit while
continuing to hold switches SW1 and SW7. When all four LEDs light solid,
release switches SW1 and SW7.
A successful association is indicated when LEDs TX and RX are rapidly blinking in unison.
Figure 12
.
PG Switch Actuation for Associate and Dissociate
To Dissociate (see Figure 12)
The PG remote must be OFF, and the base unit must have power removed before starting the
Dissociation process.
Note: The Machine Stop button must be in the UP position before activating and using the
console remote.
1. Stand near the base unit with the remote
OFF
and
power removed
from the
base unit (disconnect the P1 and P2 cables or turn the source power OFF).
2. Release the
STOP
button on the PG handheld by twisting and pulling it up.
3. Push and hold switches
SW1 UP
and
SW7 DOWN
. All four LEDs light solid.
4. Observe the LEDs. When TX begins to blink, power up the base unit while
continuing to hold switches SW1 and SW7. When all four LEDs light solid,
release SW1 and SW7.
Note: Be aware that all remote associations to the base unit are now broken.
Associate