SmaRT BU-xH6R
U078.2.3-SmaRTxH6R_BU-R
16
C1: BU-xH6R/PTO Remote Communication
To Associate
Before attempting to associate, the base unit and handheld must be OFF. Base unit and SmaRT
2-, 4-, and 6-button handheld association is established using the following steps:
1. Remove power from the base unit and turn off (time out) the handheld device.
2. Stand near the base unit in unobstructed, clear line-of-sight with the handheld in
hand.
3. Simultaneously press and hold the Associate (B1) and Dissociate (B2) buttons.
The RX and ER LEDs light.
4. Continue to hold both buttons until the TX and RX LEDs light steady.
5. When the TX and RX LEDs light, release B1 and B2. LEDs ER and BA light.
Note: If you do not immediately (within approximately 2 sec.) press the next
button, all LEDs flash, and the Associate procedure is aborted. You must then
restart the process from Step 1 to establish the communication link.
6. Immediately press and hold the Associate button (B1). All LEDs light.
7. TX begins to slowly blink. Continue to hold B1.
8. Apply power to the base unit.
The handheld and base unit begin to establish
a communication link while you hold the
Associate button. Once the process is
complete, all LEDs light briefly and then go
out.
9. Release the Associate button. The TX
and RX LEDs blink rapidly, indicating
that the base unit is communicating
with that particular handheld remote.
Figure 9. Associate/Dissociate Buttons
Associate to
base unit
Dissociate
from
base unit
1
TX
ER
RX
2