SmaRT BU-xH6R
U078.2.3-SmaRTxH6R_BU-R
18
C2: BU-xH6R/CB Remote Communication
Caution
To prevent inadvertent machine movement, be sure to
remove power from the Base Unit before attempting to
Associate or Dissociate.
Before starting the Association process, turn OFF the console box remote and remove power from
the base unit.
Note: The Machine Stop button must be in the UP position before activating and using the
console remote.
To Associate (see Figure 10)
1. Stand near the base unit with the console remote OFF and power removed from
the base unit (detach the P1 and P2 cables from the base unit, or remove the
power source.)
2. Twist and pull UP the red Stop button on the remote.
3. Hold the Associate switch (SW13) UP. While holding the Associate switch UP,
activate the console remote by holding switch SW12 UP (ON). Continue to hold
both switches.
4. Observe the LEDs. When TX begins to blink, power up the base unit while
continuing to hold SW13 and SW12. When TX, RX, ERR, and BAT light solid,
release SW13 and SW12.
A successful association is indicated when LEDs
TX
and
RX
are rapidly blinking in unison.
Figure 10. Associate and Dissociate Switch Actuations
To Dissociate (see Figure 10)
The CB remote must be OFF and the base unit must have power removed before starting the
Dissociation process.
Note: The Machine Stop button must be in the UP position before activating and using the
console remote.
1. Stand near the base unit with the console remote OFF and power removed from
the base unit (detach the P1 and P2 cables from the base unit, or remove the
power source.)
2. Twist and pull UP the red Stop button on the remote.
3. Hold the Associate switch (SW13) DOWN. While holding the Associate switch
DOWN, activate the console remote by holding switch SW12 UP (ON). Continue
to hold both switches.
4. Observe the LEDs. When TX begins to blink, power up the base unit while
continuing to hold SW13 and SW12. When TX, RX, ERR, and BAT light solid,
release SW13 and SW12.
Step 3
Step 3
Associate
Dissociate