Condensing pool heater
4
Genie S
PERFORMANCE SPECIFICATIONS
GAS CATEGORY, TYPE AND SUPPLY PRESSURE
II
2H3P
G20 @ 20 mbar
G31 @ 37 mbar
NATURAL GAS
PROPANE
MODEL
MB20S
MB35S
MB50S
MB20S
MB35S
MB50S
Corgi Work Code
TBA
1036909 1036910
TBA
1036913 1036914
HEAT
GROSS
kW
21.5
38.0
51.5
23.1
38.0
51.5
INPUT
Btu/h
73,305
129,650
179,100
78,941
129,650
179,100
NET
kW
19.5
34.2
46.4
21.3
35.0
47.5
Btu/h
66,392
116,700
158,300
72,842
119,400
162,000
TYPICAL EFFICIENCY
% gross
92 - 94
92 - 94
92 - 94
92 - 94
92 - 94
92 - 94
% net
102 - 104 102 - 104 102 - 104
102 - 104 102 - 104 102 - 104
HEAT
kW
20.0
36.9
50.0
21.5
36.9
50.0
OUTPUT
Btu/h
68,175
121,870
165,170
73,415
121,870
165,170
GAS RATE (NG, Propane)
m3/h
1.98
3.45
4.64
0.87
1.43
1.9
MAXIMUM RATE,
CO ppm
20 - 60
120-150 80-120
35 - 70
130-160 100-130
COMBUSTION SETTINGS, NG, CO2
%
8.7 - 9.0 9.2 - 9.4 9.0 - 9.4
9.9 - 10.1 10.3 - 10.5 10.0 - 10.3
OFFSET SETTING
pA
-3.0
-3.0
-3.0
-3.0
-3.0
-3.0
ORIFICE
mm
Not required
4.4
4.4
5.2
GENERAL SPECIFICATIONS
WATER CONTENT
MB20S & MB35S/MB50S
5.0 Litres / 6.0 Litres
WEIGHT (net)
MB20S & MB35S/MB50S
53 kg / 55kg
DIMENSIONS, OVERALL
375 mm wide, 520 mm deep, 980 mm high
SERVICE CLEARANCE
300mm Left, Right and Above. 800 mm In front
CORE DRILL DIAMETER
175 mm
MINIMUM
MB20S
50 l/m (3.0 m
3
/h) or 11.0 gpm
RECOMMENDED
MB35S
80 l/m (4.8 m
3
/h) or 17.6 gpm
FLOW RATE
MB50S
120 l/m (7.2m
3
/h) or 26.4 gpm)
MAX PRIMARY WATER PRESSURE
2½ bar (37 psi)
INTERNAL PUMP SETTING
Speed 3
MAXIMUM POOL TEMP
Pool 32°C (90°F) Spa 41°C (106°F)
ELECTRICAL SUPPLY
230V 50Hz, FUSED AT 5A, 130W
PROTECTION LEVEL
IP44
FLUE SYSTEM
80/125 PP, to a max. Flue Equivalent Length of 20m
1.0 TECHNICAL DATA
GB, IE
Содержание MB20S
Страница 2: ...Condensing pool heater 2 Genie S Blank page ...
Страница 32: ...5 0 Fault finding 32 Genie S Fig 11 0 5 4 SCHEMATIC WIRING ...
Страница 39: ...Condensing pool heater 39 Genie S Blank page ...
Страница 40: ...Station Lane Industrial Estate Witney Oxon Tel 01993 778855 Fax 01993 703407 June 2020 Rev J ...