5.0 Fault fi nding
30
Genie S
DISPLA
Y
LOCK / RESET
GREEN
YELLOW
RED
LED1
RED
RED
LED2
FRONT P
ANEL
ON PCB
EXPLANA
TION
‘P’
alternating with ‘oc’
= Pool sensor open circuit
OR
No net-
work detected if a Master in a multiple heater installation
‘P’
alternating with ‘cc’
= Pool sensor short circuit
‘F’
alternating with ‘oc’
= Heat Exchanger
Flow sensor open circuit
‘H’
alternating with ‘oc’
= Heat Exchanger
Combustion sensor open circuit
‘H’
alternating with ‘cc’
= Heat Exchanger
Combustion sensor short circuit
‘F’
alternating with ‘cc’
= Heat Exchanger
Flow sensor short circuit
‘Err
’ alternating with ‘4’
= Pool potentiometer open circuit
‘Err
’ alternating with ‘5’
= Pool potentiometer short circuit
For all of the above.
T
urn off
, correct problem and turn back
on again and the display and operation will be normal.