3.0 Installation
16
Genie S
Flue Kit Part Codes (cont.)
Kit Code Description
FEL
Photo of Kit
MBHT
Horizontal Wall Terminal
3.9m
MBHVE
1 metre Horiz./Vertical Extension Pipe
1.0m
MBVT
Vertical Roof Terminal
3.3m
MBOT
Outdoor Terminal
n/a
MB45DB
45 degree bends (pair)
1.1m
MB90DB
90 degree bend
1.5m
Flue
Equivalent
Length (m)
The Maximum Flue Equivalent Length (FEL) permitted is 20 metres, horizontal or vertical. The fl ue kits available
below list the FEL for each component. Add up all the FEL’s used in your design and check that this does not
exceed 20 metres
(see 3.3 for details).
(per bend)
Содержание MB20S
Страница 2: ...Condensing pool heater 2 Genie S Blank page ...
Страница 32: ...5 0 Fault finding 32 Genie S Fig 11 0 5 4 SCHEMATIC WIRING ...
Страница 39: ...Condensing pool heater 39 Genie S Blank page ...
Страница 40: ...Station Lane Industrial Estate Witney Oxon Tel 01993 778855 Fax 01993 703407 June 2020 Rev J ...