background image

FibeAir® IP-10C 

Installation Guide 

Ceragon Proprietary and Confidential 

Page 3 of 63 

Revision History 

Rev  Date 

Author 

Description 

Approved by 

Date 

November 
22, 2011 

Baruch Gitlin 

Initial release. 

Rami Lerner/Maxim 
Feldman 

November 22, 
2011 

January 1, 
2012 

Baruch Gitlin 

Added 2+0 and OMT installation 
instructions. 

Rami Lerner/Maxim 
Feldman 

January 1, 
2012 

March 14, 
2012 

Baruch Gitlin 

Update grounding procedures, 
add section on surge protection, 
revise marketing model and P/N 
data, and rearrange sections. 

Rami Lerner 

March 14, 
2012 

May 3, 2012  Baruch Gitlin 

Added 2+0 configurations. 

Rami Lerner/Maxim 
Feldman 

May 3, 2012 

June 3, 2012  Baruch Gitlin 

Add 50m single mode cable 
option. 

Rami Lerner 

June 3, 2012 

June 19, 
2012 

Baruch Gitlin 

Revise marketing model for DC 
cable drum for installation beyond 
75m. 

Rami Lerner 

June 19, 2012 

June 26, 
2012 

Baruch Gitlin 

Add list of test kits and updated 
SFP options table. 

Rami Lerner 

June 26, 2012 

October 28, 
2012 

Baruch Gitlin 

Added Appendix C: Connector 
Pin-Outs 
and revised Appendix A: 
Mediation Device Losses,
 

Rami Lerner 

October 28, 
2012 

Содержание FibeAir IP-10C

Страница 1: ...Copyright 2012 by Ceragon Networks Ltd All rights reserved d FibeAir IP 10C Installation Guide Document ID DOC 00032280 Rev H October 2012 ...

Страница 2: ...cation are owned by their respective holders Statement of Conditions The information contained in this document is subject to change without notice Ceragon Networks Ltd shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing performance or use of this document or equipment supplied with it Open Source Statement The Product may use...

Страница 3: ...tection revise marketing model and P N data and rearrange sections Rami Lerner March 14 2012 D May 3 2012 Baruch Gitlin Added 2 0 configurations Rami Lerner Maxim Feldman May 3 2012 E June 3 2012 Baruch Gitlin Add 50m single mode cable option Rami Lerner June 3 2012 F June 19 2012 Baruch Gitlin Revise marketing model for DC cable drum for installation beyond 75m Rami Lerner June 19 2012 G June 26 ...

Страница 4: ... 20 2 10 2SFP Options 20 2 10 3Accessory Kits 20 2 10 4Cap and Gland Installation 21 2 10 5Cable Installation General 22 2 10 6Preparing and Connecting a Cat5E Cable 24 2 10 7Connecting SFP Cables 27 2 10 8Connecting Bundled Cat5 Cable and Power Cable 29 2 10 9Connecting the Power Cable 30 2 11 Securing the Cables 32 2 12 Grounding the Cables to the Antenna Tower Every 50m 32 2 13 Grounding the IP...

Страница 5: ... 57 4 2 Remote Mount Installation with an Imperial Waveguide 13 15 GHz 58 4 3 Remote Mount Installation with an Imperial Waveguide 18 42 GHz 59 5 Appendix A Mediation Device Losses 60 6 Appendix B Test Kit Part Numbers 61 7 Appendix C Connector Pin Outs 62 7 1 Management Connector Pin Out 62 7 2 Power Connector Pin Out 62 7 3 Ethernet 10 100 1000 Connector Pin Out 63 7 4 Craft Terminal Connector P...

Страница 6: ... earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing and to a cable distribution system using coaxial cable may in some circumstances create a fire hazard Connection to a cable distribution system has therefore to be provided through a device providing electrical isolation below a certain frequency range galvanic is...

Страница 7: ... aux rayonnements Bruit de machine d ordre 3 GPSGV le plus haut niveau de pression sonore s élève à 70 dB A au maximum dans le respect de la norme ISO EN 7779 Allgemeine Vorsichtsmaßnahmen für die Anlage Wenn andere Steuerelemente verwendet Einstellungen vorgenommen oder Verfahren durchgeführt werden als die hier angegebenen kann dies gefährliche Strahlung verursachen Maschinenlärminformations Ver...

Страница 8: ... IP 10Q and RFU C systems The IP 10C is part of Ceragon s outdoor system using the same waveguide and accessories Target Audience This guide contains technical information about IP 10C installation and is intended for use by qualified Ceragon technical personnel at all levels Related Documents FibeAir IP 10C Product Description DOC 00029987 FibeAir IP 10C User Guide DOC 00035560 FibeAir IP 10C MIB...

Страница 9: ...ew FibeAir IP 10C is a state of the art all outdoor unit which is fully software configurable and supports a broad range of capacities and interfaces IP 10C Front View IP 10C Rear View IP 10C provides a powerful reliable and comprehensive solution for a variety of wireless network scenarios and requirements ...

Страница 10: ...ead socket key wrench metric set Phillips screwdriver 1 2 Slot screwdriver 0 5x3x100 Slot screwdriver 1 6x10x200 Locking Pliers with plastic teeth Wrench 24mm 2 2 Transportation The equipment should be prepared for public transportation The cargo must be kept dry during transportation in accordance with ETS 300 019 1 2 Class 2 3 It is recommended that the equipment be transported to the installati...

Страница 11: ...ncludes the following items IP 10C unit 2 Glands 5 Caps Adapting bar kit 2 DC power connectors 2 4 Location of the IP 10C Restricted Access Area The IP 10C is intended for installation in a Restricted Access Area Distance The IP 10C shall be installed within 140 feet 42 67 meters from the building Otherwise Ethernet and other SELV connections will turn to TNV The IP 10C shall be installed in accor...

Страница 12: ...Proprietary and Confidential Page 12 of 63 2 5 Installation Components The following figures show the main components used in the IP 10C installation procedures IP 10C Adapting Bar V H Twist Coupler Holder with Coupler OMT Remote Pole Mount Kit ...

Страница 13: ...it RFU C13 TWST Kit RFU C15 TWST Kit RFU C18 TWST Kit RFU C23_26 TWST Kit RFU C28_32 TWST Kit RFU C38 TWST Kit RFU C42 TWST Kit RFU C OMT KIT RFU C6 OMT DM Kit RFU C7_8 OMT DM Kit RFU C10_11 OMT DM Kit RFU C13 OMT DM Kit RFU C15 OMT DM Kit RFU C18 OMT DM Kit RFU C23 OMT DM Kit RFU C26 OMT DM Kit RFU C28 OMT DM Kit RFU C32 OMT DM Kit RFU C38 OMT DM Kit RFU C42 OMT DM Kit RFU C ADAPTORS OMT KIT RFU ...

Страница 14: ... GD RFU C18 OMT INT GD RFU C23 OMT INT GD RFU C26 OMT INT GD RFU C28 OMT INT GD RFU C32 OMT INT GD RFU C38 OMT INT GD NA Radio Waves RFU C6L OMT INT RW RFU C6H OMT INT RW RFU C7_8 OMT INT RW RFU C10_11 OMT INT RW RFU C13 OMT INT RW RFU C15 OMT INT RW RFU C18 OMT INT RW RFU C23 OMT INT RW RFU C26 OMT INT RW RFU C28 OMT INT RW NA RFU C38 OMT INT RW NA Shenglu RFU C7_8 OMT INT SH RFU C10_11 OMT INT S...

Страница 15: ...na type CPR flange is used a flange adaptor is required Please contact your Ceragon representative for details Note Conductive grease must be applied to the screws that connect the IP 10C to the antenna interface Frequency Circ WG Diameter Rect WG Flange Des Radio Side Remote Flange Des Flex WG Side A Flange Des Flex WG Side B Flange Des Antenna Remote Flange Des Band Range GHz 6 L U GHz 5 8 7 1 3...

Страница 16: ...rizontal and Vertical Polarization Polarization changes in the IP 10C are made by adjusting the iris on the antenna port Attach the iris using two M3 screws according to the antenna polarization For horizontal polarization locate the holes above and below the letter H on the pins and fasten the two screws ...

Страница 17: ...kage 2 9 Connecting Flexible Waveguides to the IP 10C For an IP 10C operating in bands of 6 13 GHz a remote mount adaptor must be used to connect a flexible waveguide For an IP 10C operating in bands of 15 42 GHz you must remove the iris before connecting a flexible waveguide to the antenna port The following table provides the marketing models for the remote mount waveguide adaptor kits required ...

Страница 18: ...e screws 2 Connect the flexible waveguide to the remote mount adaptor Use screws supplied with the waveguide kit to fasten the waveguide 2 9 2 Connecting the Waveguide in 15 42 GHz Bands 1 Remove the iris from the IP 10C no adaptor is required for the 15 42 GHz bands 2 Connect the waveguide to the antenna adaptor interface the interface exposed by removing the iris Use four screws supplied with th...

Страница 19: ...Air IP 10C Installation Guide Ceragon Proprietary and Confidential Page 19 of 63 Note It is normal for the flexible waveguide to reach the IP 10C at an angle of approximately 45 as shown in the figure below ...

Страница 20: ...llation up to 75m Outdoor_DC_cbl_2x12AWG_drum DC cable drum for installation beyond 75m OP MM CBL LC LC DPLX 100M OUT Optical cable Multi Mode LC LC 100m OUTDOOR OP MM CBL LC LC DPLX 75M OUT Optical cable Multi Mode LC LC 75m OUTDOOR OP MM CBL LC LC DPLX 50M OUT Optical cable Multi Mode LC LC 50m OUTDOOR OP SM CBL LC LC DPLX 100M OUT Optical cable Single Mode LC LC 100m OUTDOOR OP SM CBL LC LC DPL...

Страница 21: ...Gland Installation 1 Mount the gland cap with the O Ring to the desired location and tighen it until there is full contact see figure below between the gland gland cap and the cover Use the large 1 6x10x200 slot screwdriver to tighten the cap Use the locking pliers or 24mm wrench to tighten the gland ...

Страница 22: ... 10C Note Do not remove the gasket Do not remove or cut the wire securing the cover to the IP 10C 2 Connect the cables as described in detail in the following sections Preparing and Connecting a Cat5E Cable Connecting the Power Cable Connecting SFP Cable Connecting Bundled Cat5 Cable and Power Cable 3 Close the bottom cover using five M4 captive screws ...

Страница 23: ...ragon Proprietary and Confidential Page 23 of 63 4 Thread the screws without fastening After all five screws are threaded in the required location tighten the screws diagonally with 2 6Nm torque 5 Tighten the gland cap using 10 Nm torque ...

Страница 24: ...ff about 70mm of the outer insulation jacket 7 Strip off about 15mm of the inner insulation jacket 8 Release the gland cap slightly 9 Insert the Cat5 cable into the Cable gland 10 Insert the Cat5 plug boot into the cable with its face up 11 Roll back the foil shield insulation and wrap the drain wire around the foil Do not remove any insulation from the conductors ...

Страница 25: ... front of the RJ45 plug and in the correct order The sheath of the Ethernet cable should extend into the plug by about inches and will be held in place by the crimp 15 The cable jacket with shield must extend into the connector about 5mm for strain relief and shielding connection 16 Crimp the RJ45 plug with the crimper tool 17 Verify that the wires ended up the right order and that the wires exten...

Страница 26: ... the relevant hole in the small cover and tighten until there is full contact between the gland and the cover 21 Connect the assembled connector into the IP 10C plug connector 22 Once all the cables have been installed close the small cover using five captive screws and tighten the gland cap with 10 Nm torque ...

Страница 27: ...necting SFP Cables 1 Use a pre assembled cable 2 Split the connector into two separate blue units one for each wire 3 Release the gland cap slightly 4 Insert wires with connector one by one into the cable gland 5 Disassemble the middle cap 6 Insert the cable wires one by one into the middle hole ...

Страница 28: ...er and tighten unti there is full contact 8 Connect the connector into the IP 10C plug connector 9 Insert the gland into the small cover and tighten until there is full contact between the gland and the cover 10 Once all the cables have been installed close the small cover using five captive screws and tighten the gland cap with 10 Nm torque ...

Страница 29: ...ng the Power Cable 3 Connect the assembled Cat5 connector into the IP 10C plug connector 4 Connect the power cable to the power connector in the IP 10C as described in steps 9 through 10 in section 2 10 9 Connecting the Power Cable 5 Connect the grounding shield to the body with serrated washers plain washer and M6 Nut 6 Once all the cables have been installed close the small cover using five capt...

Страница 30: ...e two wires 3 Replace the left cap with a gland and tighten it Tighten until there is full contact 4 Release the gland cap slightly 5 Insert the power cable into the gland assembled in the small cover 6 Insert the power cable wires into the power connector 7 Match and to the red and black cord colors according to the power supply connection cord colors for and locations refer to the figure below ...

Страница 31: ...31 of 63 8 Tighten the two top screws 9 Plug in the power cable with connector into the IP 10C power connector 10 Tighten the two front screws 11 Once all the cables have been installed close the small cover using five captive screws and tighten the gland cap with 10 Nm torque ...

Страница 32: ...BLE 2 WAY The following clamps are available for bundled Cat5 cables Part Number Marketing Model Item Description SI 0766 0 RG8 8 feeder clamp DUAL FEADER CLAMP FOR RG 8 U CABLE 8 WAY SI 0765 0 RG8 6 feeder clamp DUAL FEADER CLAMP FOR RG 8 U CABLE 6 WAY SI 0764 0 RG8 4 feeder clamp DUAL FEADER CLAMP FOR RG 8 U CABLE 4 WAY SI 0763 0 RG8 2 feeder clamp DUAL FEADER CLAMP FOR RG 8 U CABLE 2 WAY 2 12 G...

Страница 33: ... shall be installed for full power disconnection in a building installation Any outdoor antenna cable shield shall be permanently connected to protective earth in a building installation When selecting a power source the following must be considered DC power can be from 40 VDC to 60 VDC Recommended Availability of a UPS Uninterrupted Power Source battery backup and emergency power generator Whethe...

Страница 34: ...ion IP 10C includes built in surge protection for its Ethernet and power interfaces IP 10C s surge protection mechanism complies with surge immunity standard IEC 61000 4 5 level 4 provided the Ethernet cables were prepared according to the instructions in Preparing and Connecting a Cat5E Cable on page 24 ...

Страница 35: ...d on the antenna without the use of flexible waveguides 1 Adjust the iris according to the required polarization 2 Mount the adapting bar using two M8 flat screws on the antenna 3 Mount the IP 10C on the antenna using the four M8 captive screws and washers supplied assembled in the IP 10C and thread the screws without fastening After all four screws are threaded to the required location tighten th...

Страница 36: ...nd tighten the screws 2 Mount the adapting bar using two M8 flat screws 3 Mount the IP 10C on the antenna using the four M8 captive screws and washers supplied assembled in the IP 10C and thread the screws without fastening After all four screws are threaded to the required location tighten the screws starting from the bottom screws 4 Place the O Ring into the flange groove on both ends of the fle...

Страница 37: ... the IP 10C and thread the screws without fastening After all four screws are threaded to the required location tighten the screws starting from the bottom screws 4 Place the O Ring into the flange groove on both ends of the flexible waveguide 5 Connect the flexible waveguide to the IP 10C antenna adaptor interface the interface exposed by removing the iris Note It is normal for the flexible waveg...

Страница 38: ...se four screws and washers supplied with the waveguide kit to fasten the waveguide end to the antenna adapter interface 7 Mount the flexible waveguide on the antenna and tighten the screws and washers 8 Connect the cables as described in Cable Connections and Grounding Procedure on page 20 ...

Страница 39: ... pressure window located on the coupler ports To install an IP 10C in a 1 1 HSB direct mount configuration Notes For 15 and 18 GHz frequencies two O Rings are supplied in the Twist kit and should be mounted in the twist grooves For the 6 GHz frequency a gasket is used instead of an O Ring The gasket should be mounted between the twist and the RFU C Coupler kit 1 Mount the twist to the coupler usin...

Страница 40: ...wo O Rings supplied with the RFU C Coupler kit as shown in the following figures 4 Mount the adapting bar on the coupler holder using two M8 flat screws 5 Mount both IP 10C units on the coupler holder and tighten them using the four M8 captive screws and washers supplied with the IP 10C Thread the screws without fastening After all four screws are threaded in the correct location tighten the screw...

Страница 41: ...FibeAir IP 10C Installation Guide Ceragon Proprietary and Confidential Page 41 of 63 Important Pay attention to the polarization mounting direction ...

Страница 42: ...configuration the IP 10C is attached to a coupler Important Do not remove the transparent pressure window located on the coupler ports To install an IP 10C in a 1 1 HSB remote mount configuration 1 For 6 13 GHz installations only mount the RFU C remote adaptor and O Ring to the pole mount using the four flat M5 screws supplied in the RFU C Remote Mount Adaptor kit and tighten the screws 2 Mount th...

Страница 43: ...em using the four M8 captive screws and washers supplied with the IP 10C Thread the screws without fastening After all four screws are threaded in the correct location tighten the screws starting from the bottom screws 6 Place the O Ring in the flexible waveguide flange groove 7 Mount the flexible waveguide on the coupler and tighten the screws and washers 8 Place the O Ring in the other end of th...

Страница 44: ...uantity Remarks I IP 10C RADIO 2 2 RFU C SYMMETRICAL COUPLER KIT 1 3 RFU C TWIST 1 In 2 0 direct mount configuration the IP 10 C is attached to a symmetrical coupler Important Do not remove the transparent pressure window located on the symmetrical coupler ports To install an IP 10C in a 2 0 SP direct mount configuration 1 Remove the Extender from the Symmetrical Coupler by loosening and removing ...

Страница 45: ...For 15 and 18 GHz frequencies two O Rings are supplied in the Twist Kit and should be mounted in the twist grooves For the 6 GHz frequency a gasket is used instead of an O Ring The gasket should be mounted between the twist and the RFU C Circulator Symmetrical Coupler Kit Important Make sure the polarization mounting direction of the twist to the RFU C circulator symmetrical coupler is according t...

Страница 46: ... the screws 4 Mount the two O Rings supplied with the RFU C Circulator Symmetrical Coupler Kit 5 Mount the adapting bar on the coupler holder using two M8 flat screws 6 Mount both IP 10C units on the coupler holder and tighten them using the four M8 captive screws and washers supplied with the IP 10C Thread the screws without fastening After all four screws are threaded in the correct location tig...

Страница 47: ...FibeAir IP 10C Installation Guide Ceragon Proprietary and Confidential Page 47 of 63 Important Pay attention to the polarization mounting direction ...

Страница 48: ...10C RADIO 2 2 RFU C SYMMETRICAL COUPLER KIT 1 3 RFU C REMOTE MOUNT KIT 1 In 2 0 SP remote mount configuration the IP 10C is attached to a symmetrical coupler Important Do not remove the transparent pressure window located on the symmetrical coupler ports To install an IP 10C in a 2 0 SP remote mount configuration 1 Mount the IP 10C coupler to the RFU C pole mount bracket using the four M8 screws a...

Страница 49: ...ten them using the four M8 captive screws and washers supplied with the IP 10C Thread the screws without fastening After all four screws are threaded in the correct location tighten the screws starting from the bottom screws 5 Place the O Ring in the flexible waveguide flange groove 6 Mount the flexible waveguide on the coupler and tighten the screws and washers 7 Place the O Ring in the other end...

Страница 50: ...ode Transducer OMT Important Do not remove the transparent pressure window located on the OMT ports The following components are necessary for a 2 0 DP installation Item Description Quantity Remarks 1 ANTENNA OMT ADAPTOR 1 2 RFU C OMT 1 3 IP 10C 2 1 Prior to the installation follow the antenna manufacturer s instructions to switch to a circular adaptor remove the existing rectangular adapter swap ...

Страница 51: ...he OMT kit Do not tighten them yet to allow rotation of the entire assembly 3 Mount the two O Rings supplied with the OMT kit on the OMT body Pay attention to the mounting direction as shown in the section view 4 Connect the iris to the IP 10C using two M3 screws according to the OMT port polarization 5 Mount the adapting bar on the OMT holder using two M8 flat screws ...

Страница 52: ...P 10C Thread the screws without fastening After all four screws are threaded in the correct locations tighten the screws starting from the bottom screws Important Pay attention to the polarization mounting direction 9 Tilt the entire assembly to achieve maximum XPD Cross Polar Differentiation 10 Connect the cables and ground the IP 10C units as described in Cable Connections and Grounding Procedur...

Страница 53: ...t remove the transparent pressure window located on the OMT ports The following components are necessary for a 2 0 DP remote installation Item Description Quantity Remarks 1 ANTENNA OMT ADAPTOR 1 2 RFU C OMT 1 3 IP 10C 2 4 RFU C OMT ADAPTOR KIT 1 Optional 5 RFU C REMOTE MOUNT KIT 1 Freq WG standard 6HGz UDR70 7 8GHz UBR84 10 11GHz UBR100 IPPON ADAPTORS OMT KIT RFU C6 OMT ADAPT RFU C7_8 OMT ADAPT R...

Страница 54: ...de as usual 12 For 7 11 GHz UBR84 and UBR100 i Mount the O Ring supplied with the OMT kit ii Mount the OMT adaptor with its installed sealing gasket on the OMT and tighten using the four M4 screws and washers supplied with the OMT Adaptor kit iii Mount the flexible waveguide without its gasket only for the OMT side ...

Страница 55: ...ry and Confidential Page 55 of 63 13 For 13 GHz UBR120 to 42 GHz UG383 U connect the flexible waveguide and its gasket supplied with the Flexible WG Kit directly to the OMT port 14 Connect the other end of the flexible waveguide to the IP 10C Radio port ...

Страница 56: ...nstallation with an Imperial Waveguide List of Items Item Description Quantity Remarks 1 IP 10C RADIO 1 2 FLEXIBLE WG IMPERIAL KIT 1 3 RFU C REMOTE MOUNT ADAPTOR KIT 1 Up to 15 GHz 4 RFU C REMOTE POLE MOUNT KIT 1 Required Tools Metric offset hexagon key wrench set Imperial offset hexagon key wrench set ...

Страница 57: ...t the adapting bar using two M8 flat screws 3 Mount the IP 10C unit on the Remote Pole Mount kit and tighten it using the four M8 captive screws and washers supplied with the IP 10C Thread the screws without fastening After all four screws are threaded in the correct location tighten the screws starting from the bottom screws 4 Connect the Flexible Waveguide and Sealing Gasket supplied with the Fl...

Страница 58: ...bar using two M8 flat screws 3 Mount the IP 10C unit on the Remote Pole Mount kit and tighten it using the four M8 captive screws and washers supplied with the IP 10C Thread the screws without fastening After all four screws are threaded in the correct location tighten the screws starting from the bottom screws 4 Connect the Flexible Waveguide and sealing O Ring supplied with the Flexible Waveguid...

Страница 59: ...nt the adapting bar using two M8 flat screws 3 Mount the IP 10C unit on the pole mount bracket and tighten it using the four M8 captive screws and washers supplied with the IP 10C Thread the screws without fastening After all four screws are threaded in the correct location tighten the screws starting from the bottom screws 4 Connect the Flexible Waveguide and sealing O Ring supplied with the Flex...

Страница 60: ...15 GHz 18 26 GHz 28 42 GHz Flex WG Remote Mount antenna Added on remote mount configurations 0 5 0 5 1 2 1 5 1 5 1 0 DirectMount Integrated antenna 0 2 0 2 0 4 0 5 0 5 1 1 HSB Direct Mount Main Path 1 6 1 6 1 8 1 8 1 8 with asymmetrical coupler Secondary Path 6 6 6 6 6 2 0 DP OMT Direct Mount Integrated antenna 0 5 0 5 0 5 0 5 0 5 2 2 HSB OMT Remote Mount Main Path 1 9 1 9 2 1 2 1 2 1 with asymmet...

Страница 61: ...6 TS X 7 8 GHz RFU C7_8 TS NP RFU C7_8 TS P RFU C7_8 TS X 10 11 GHz RFU C10_11 TS NP RFU C10_11 TS P RFU C10_11 TS X 13 GHz RFU C13 TS NP RFU C13 TS P RFU C13 TS X 15 GHz RFU C15 TS NP RFU C15 TS P RFU C15 TS X 18 26 GHz RFU C18_26 TS NP RFU C18_26 TS P RFU C18_26 TS X 28 38 GHz RFU C28_38 TS NP RFU C28_38 TS P RFU C28_38 TS X 42 GHz RFU C42 TS NP RFU C42 TS P RFU C42 TS X ...

Страница 62: ... Ethernet 10 100 1000 Connector Craft Terminal 7 1 Management Connector Pin Out The management connector is an RJ 45 8 pin female type connector RJ 45 Male Connector Pin Signal 1 Twisted Pair Out Tx 2 3 Twisted Pair In Rx 6 4 Not Connected 5 7 Not Connected 8 7 2 Power Connector Pin Out The power connector pin out is as follows Left Pin 1 Right Pin 2 48V return current 0V Note that right left refe...

Страница 63: ...air Tx Rx 5 7 Twisted Pair Tx Rx 8 7 4 Craft Terminal Connector Pin Out The craft terminal is an RJ 45 8 pin female type connector The following table shows the pin out values for the RJ 45 craft terminal connector In addition the table shows the cross connect values when using an RJ 45 to DB9 adapter to connect from the IP 10Q s craft terminal to a DB9 connector RJ 45 Female Connector Pin Name Di...