7. Testing
Turn the selector to
TEST/RESET
mode.
Serial Testing of the Programmed Valves
Press simultaneously on and the
for 4 seconds. All the programmed valves
will appear on the display panel and
a drop will appear in line with the first
valve showing that this valve is open.
Press on . The first valve will close and
the sequential valve will open.
If one of the valves is short-circuited the
drop in line with the valve will blink.
The valve must be detached or the short
circuit repaired to enable the testing to
be continued.
Testing of an Individual Valve
Press on . The symbols
of all the
valves will appear, and the symbol of
valve 1 will blink.
Using select the necessary valve
needed to be tested (the symbol of
the selected valve will blink).
Press on . The selected valve will open
and the drop symbol will appear in
line with it. Press .The valve will close.
Please Note: In order to enable the
fertilizer valve to be tested, it is
necessary to open one of the valves
and the main valve (if there is a main
valve) manually in order to ascertain
a flow of water, and only then may
an electrical testing of the fertilizater
valve be done.
8.
RESET
It is possible to delete all of the controller's programs.
Turn the selector to Test/Reset .
Press simultaneously on and for 4 seconds. All of the controller's programs will
be deleted. The full display will appear on the screen signifying the deletion of all
of the programs. The procedure has been completed successfully. The no. of valves
and MNF. code will appear on the screen. The controller must now be reprogrammed.
RAIN
OFF
TEST /
RESET
TIME / DAY
RUN
MANUAL
PROGRAM
WEEKLY /
CYCLIC
START
VALVES
DURATION
VALVE
DURATION
START
FERTILIZER
SENSOR
WATER
BUDGET
PROGRAM
A-B-C
INDEPENDENT
I
WEEKLY /
CYCLIC
TEST/RESET
The selector should be returned to the TIME/DAY mode
following modification or ending of the program.
No of valve
installed
MNF. Code
Advanced Programming
EN
Содержание CMC-08-24
Страница 72: ......