Installation and Operation Manual - FW2800
ENGLISH
8.1 Clearances
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
Canada
USA
A
14
½
" (368 mm)
13" (330 mm)
A
7 ½" (191 mm)
7 ½" (191 mm)
B
16" (406 mm)
15" (381 mm)
B
16" (406 mm)
15" (381 mm)
C
12" (305 mm)
12" (305 mm)
C
12" (305 mm)
12" (305 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
13
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
Canada
USA
D
18" (457 mm)
16 ½" (419 mm)
D
11" (279 mm)
11" (279 mm)
E
25" (635 mm)
24" (610 mm)
E
25" (635 mm)
24" (610 mm)
F
20 ¾" (527 mm)
20 ¾" (527 mm)
F
20 ¾" (527 mm)
20 ¾" (527 mm)
8.1.1 With Heat Shield AC02762
14
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
USA
Canada
USA
A
3" (76 mm)
3" (76 mm)
D
6 ½" (165 mm)
6 ½" (165 mm)
B
5" (127 mm)
5" (127 mm)
E
14" (356 mm)
14" (356 mm)
C
3" (76 mm)
3" (76 mm)
F
11 ¾" (298 mm)
11 ¾» (298 mm)
13
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
14
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
connector to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certified double
wall pipe connector can be used.
Содержание CB00021
Страница 2: ......
Страница 6: ...Page 6 Installation and Operation Manual FW2800 ENGLISH CERTIFICATION PLATE ...
Страница 48: ...Page 48 Installation and Operation Manual FW2800 ENGLISH Appendix 6 MOBILE HOME INSTALLATION ...
Страница 53: ...Page 53 Installation and Operation Manual FW2800 ENGLISH NOTES ...
Страница 54: ...Page 54 Installation and Operation Manual FW2800 ENGLISH NOTES ...