FIGURE 27.
FIGURE 28.
Examples:
A. Setting up the gate Limits
This is usually performed by an installer at the end of the installation.
However, should you need to change these settings, you can do this by
simply following these steps:
Step 1:
Ensure the gate is in the fully closed position and the motor
drive is engaged.
Step 2:
Rotate the Function Dial
to the LIMITS position (A).
Step 3:
Rotate the Setting Dial
to the SETUP position along the
‘A’ row of options.
Step 4
: Press the pushbutton to
select this feature.
The gate will then run through
its automated procedure to
determine the gate's open and
closed positions. If setup is
successful, the status LED will
be green, which indicates the
setup has finished.
FIGURE 26.
Step 5:
Return the Function
Dial to the RUN position.
FIGURE 29.
Customising
the
Features
and
Functions