background image

Customising 

the

Features

and 

Functions

page 16

4. Customising the Features and 
    Functions

‘Simplicity is the ultimate sophistication’. ~ Leonardo Da Vinci

The 

D2 Turbo 

controller makes ordinarily complex settings as quick 

and easy as possible. Using the 

Function 

and

 Setting Dials

, the 

select/Toggle pushbutton     

, and the bi-colour (red and green) 

status LED

 you can set up the many features and functions in a flash.

FIGURE 20.

Please always adjust the 

Function Dial

 first. 

Set this to the desired function. 

FIGURE 21.

Function Dial

Settings Dial

Settings Dial

D2 Turbo controller (orange)

D2 Turbo Low-Voltage controller (dark green)

Function Dial

Function Dial

Select/

Toggle 

pushbutton

Select/

Toggle 

pushbutton

Содержание D2 Turbo

Страница 1: ...D2 Turbo and D2 Turbo Low Voltage User Guide DOMESTIC SLIDING GATE MOTOR e g a t l o V w o L ...

Страница 2: ...ugh a team of dedicated technicians and sales personnel together with a fully fledged in house training facility we are committed to providing unmatched service and support for our products The equipment is installed worldwide and is available through a network of competent distributors and installers Further information is available on our website www CentSys com au Company Overview Centurion Sys...

Страница 3: ...5 PIRAC Mode Beam Autoclose optional 3 1 6 Holiday Lockout Mode 3 1 7 Positive Close Mode 3 1 8 Speed Profiles 3 1 9 Anti crushing Sensitivity 3 1 10 Photocell s optional but recommended feature 3 1 10 1 Closing Photocell s 3 1 10 2 Opening Photocell s 3 1 11 Courtesy Pillar Light Timer optional feature 3 1 11 1 Courtesy Pillar Light acts as Warning Light 3 1 11 1A Pre flashing Modes 3 1 12 Extern...

Страница 4: ...opping remote controls D Deleting specific remote controls E Deleting ALL remote controls F Setting the Autoclose feature G Setting the Mode of Operation H Setting PIRAC Mode I Setting the Pre flashing Modes J Setting the Operating Profiles K Verifying your setup L Reverting to factory defaults M Factory defaults schedule 5 Additional Features 5 1 Battery saver 5 2 Solar power supply 6 Basic Maint...

Страница 5: ...e path of a moving gate 3 Check if the obstruction detection system and safety devices for correct operation are in working order once a month 4 Children should be supervised to ensure that they do not play with the appliance 5 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they ha...

Страница 6: ...ust still be grounded to the motor base plate as this serves as lightning protection The diameter of the cable needed to supply power to the system will depend on the distance between the transformer and the motor as well as on the output voltage of the transformer used The table below shows the typical cable thicknesses for corresponding distance and assumes a 16V AC transformer output Distance f...

Страница 7: ... out For increased power capacity you can install a larger 7Ah battery your D2 Turbo was designed to cater for this or you can even use a solar panel to power it See the section on solar panels for more details about solar charging The D2 Turbo is designed to open and close domestic sliding gates weighing up to 250kg It must not be installed or used to automate the entrances of townhouse complexes...

Страница 8: ...mlock cover 4 Manual elease R thumbwheel 5 Foundation plate 6 Function Dial 7 Status LED 8 Pushbutton 9 D2 Turbo 230V orange controller D2 Turbo Low Voltage dark green controller 1 0 Selection knob 1 1 12V 7 2Ah or 5Ah battery 1 Battery strap 2 1 Pulley guard 3 14 Spare fuse 15 Gate mounted origin marker 16 Origin marker bracket 17 Motor housing 18 Pinion 19 Pinion guard 15 6 7 8 9 10 11 12 14 13 ...

Страница 9: ...clockwise until it clicks the motor pinion will be put into Manual Mode 2 Manual Override 2 2 Re engaging the gearbox drive To re engage the drive mechanism of the motor turn the Manual Release thumbwheel 90 clockwise until it clicks Once you have re engaged the drive mechanism don t forget to lock the camlock by inserting the key and rotating it 90 counter clockwise this will help prevent unautho...

Страница 10: ...ndset is usually fitted with a gate pushbutton which when pressed sends a signal to the D2 Turbo controller to operate the gate FIGURE 4 FIGURE 5 3 1 2 Modes of Operation To operate the gate to open fully the D2 Turbo has three modes to choose from depending on the application Only one mode can be selected at any given time 3 1 2 1 Standard Mode Standard Mode is the most commonly used mode for dom...

Страница 11: ...e Autoclose timer page 8 will be reset We highly recommend that a pair of are photocells installed across the gate entrance and connected to the C S B D2 Turbo losing afety eam input on the if you select Open Only Mode This will prevent the gate from closing on people pets or vehicles page 13 PIRAC Beam Autoclose page can be used with Open 10 Only Mode 3 1 2 3 Reversing Mode Reversing Mode offers ...

Страница 12: ...Closing Autoclose Mode The D2 Turbo has the facility to automatically close the gate after it has opened Autoclose Mode The time that the gate stays open is by default fifteen seconds but this time period can be set to be five ten fifteen thirty or forty five seconds As described in the previous section Autoclose Mode is selectable with Standard Mode page 6 and Reversing Mode page 7 by default the...

Страница 13: ...ge is connected to the D2 Turbo control 14 card it will flash indicating that the gate will open approximately one metre The gate will close after a default time of five seconds The gate can be kept open by keeping a trigger on the input keeping your key in the keyswitch for example once removed the gate will close after the fixed five seconds If a Closing Photocell page is fitted and the beam is ...

Страница 14: ...d but nothing moves through the Closing Photocell the gate will stay fully open for the duration of the Autoclose timer before closing However if something passes through the closing beam the gate will close immediately If something crosses the photocells while the gate is opening the gate will continue to open until the beam is cleared Once the beam is cleared the gate will stop and close If the ...

Страница 15: ...ices that are connected to the D2 Turbo will be rendered inactive Not even tampering with the keyswitch or keypad on the outside of the property will open the gate this is particularly useful if you intend leaving your property unattended for extended periods of time If Holiday Lockout is enabled while the gate is moving or in the open position it will only activate once the gate is back in the cl...

Страница 16: ... a High Speed Mode default which is approximately 24 metres per minute or a Low Speed Mode which is approximately 16 metres per minute High speeds offer a greater level of convenience and security while slower speeds ensure increased levels of safety at the gate To change the Speed Profile please refer to the section Customising the eatures and unctions on page F F 16 3 1 9 Anti crushing Sensitivi...

Страница 17: ...itional protection against your gate closing on people or vehicles If the beam is broken while the gate is opening the gate will continue to open If the gate is open the gate cannot be closed if the beam is broken and if the gate is closing when the beam is broken it will stop and re open If you select the Autoclose page feature the gate will remain 10 open if the beam is broken and it will only c...

Страница 18: ...use the gate motor Using the Pedestrian Opening feature will cause the Courtesy Pillar Lights to flash three times before the gate opens The cabling that supplies the supply to the D2 Turbo must be suitably sized to carries the additional load of the Courtesy Pillar Lights or a separate power source must be utilised 3 1 11 1 Courtesy Pillar Lights act as Warning Light These modes replace the stand...

Страница 19: ...of your home The different signals of the LED are described below If you choose not to fit a Gate Status Indicator the status LED on the controller can also be used for troubleshooting 3 1 13 Battery low Protection The D2 Turbo controller has circuitry that monitors the state of the battery During a power failure energy is drawn from the battery but not replaced To protect the battery from being d...

Страница 20: ...e Function and Setting Dials the select Toggle pushbutton and the bi colour red and green status LED you can set up the many features and functions in a flash FIGURE 20 Please always adjust the Function Dial first Set this to the desired function FIGURE 21 Function Dial Settings Dial Settings Dial D2 Turbo controller orange D2 Turbo Low Voltage controller dark green Function Dial Function Dial Sel...

Страница 21: ...4 FIGURE 25 When using the Select pushbutton to toggle between preferences the status LED will light up as green to indicate On or High or alternatively red to indicate Off or Low The Function Dial must always be returned to the Run position rotated fully counter clockwise after you have finished setting up any of the features modes or profiles This ensures that it will be ready for use Customisin...

Страница 22: ...ngaged Step 2 Rotate the Function Dial to the LIMITS position A Step 3 Rotate the Setting Dial to the SETUP position along the A row of options Step 4 Press the pushbutton to select this feature The gate will then run through its automated procedure to determine the gate s open and closed positions If setup is successful the status LED will be green which indicates the setup has finished FIGURE 26...

Страница 23: ... a four button transmitter gains two extra buttons and can operate six functions This is quite handy if you d like to control additional devices from a single multi button remote control for example your garage doors if they are equipped with CentSys code hopping receivers It s important to note that the other devices cannot be activated with the new shift button only the D2 Turbo and other CentSy...

Страница 24: ...n Tx PED to assign a remote control button to be learned into the system and partially open the gate for a pedestrian Tx LCK to assign a remote control button to be learned into the system and activate Holiday Lockout Mode Step 3 Press the pushbutton to select the setting chosen from above the status LED will change from red to green to confirm the setting Step 4 Press the desired button on the re...

Страница 25: ...er s memory Step 3 Press the pushbutton to select the status LED will change from red to green to confirm the setting FIGURE 36 Step 5 Return the Function Dial to the RUN position Step 4 Press any button on the specific remote control s that you want to delete from the onboard receiver s memory The status LED will flash green three times and the buzzer will also beep three times indicating that th...

Страница 26: ... ALL position along the B row of options This will delete all remote controls from the onboard receiver s memory Step 3 Press the pushbutton to select the setting The status LED will initially flash red Hold down the pushbutton button until the status LED turns green and three beeps are heard This will indicate that the onboard receiver has deleted the remote control s from its memory FIGURE 40 FI...

Страница 27: ... Dial to the desired time delay setting along the C row of options You can choose either 5 seconds 10 seconds 15 seconds 30 seconds or 45 seconds Step 3 Press the pushbutton to select your choice The status LED will change from red to green indicating that the Autoclose feature has been activated with the delay time selected in Step 2 Step 4 Return the Function Dial to the RUN position FIGURE 43 P...

Страница 28: ...long the C row of options The status LED will be red if Autoclose is on If it is already Off the status LED will be green Step 3 Press the pushbutton to select The status LED will change from red to green indicating that the Autoclose feature has been deactivated or switched Off FIGURE 47 FIGURE 49 Step 4 Return the Function Dial to the RUN position Please note that if the motor is running in Open...

Страница 29: ...lection along the D row of options G2 Open Only Mode Step 1 Rotate the Function Dial to the MODE position D Step 2 Rotate the Setting Dial to the OPEN ONLY selection along the D row of options Step 3 Press the pushbutton to select the setting The status LED will change from red to green indicating that the Standard Operating Mode has been activated FIGURE 50 FIGURE 53 Step 4 Return the Function Di...

Страница 30: ...otate the Function Dial to the MODE position D Step 2 Rotate the Setting Dial to the REVERSING selection along the D row of options Step 3 Press the pushbutton to select the setting The status LED will change from red to green indicating that the Reversing Mode has been activated FIGURE 56 Step 4 Return the Function Dial to the RUN position FIGURE 57 FIGURE 58 PIRAC Mode can be active while in Sta...

Страница 31: ...lowing steps Step 1 Rotate the Function Dial to the MODE position D Step 2 Rotate the Setting Dial to the PIRAC On Off selection along the D row of options Step 3 Press the pushbutton to toggle between On and Off The status LED will change from red to green indicating that PIRAC has been activated or it will change to red indicating that PIRAC Mode has been de activated FIGURE 59 Step 4 Return the...

Страница 32: ...l to the MODE position D Step 2 Rotate the Setting Dial to either PFA On Off for Pre flashing Mode A or PFC On Off for Pre flashing Mode C along the D row of options Step 3 Press the pushbutton to toggle the Pre flashing Mode between On and Off The status LED will change from red to green indicating that the selected Pre flashing Mode has been activated or it will change to red indicating that it ...

Страница 33: ...ode please follow these steps Step 1 Rotate the Function Dial to the PROFILE position E Step 2 Rotate the Setting Dial to PCM on off along the E row of options Step 3 Press the pushbutton to toggle the chosen mode between On and Off The status LED will change from red to green indicating that the selected Positive Close Mode has been activated or it will change to red indicating that it has been d...

Страница 34: ...tion Dial to the PROFILE position E Step 2 Rotate the Setting Dial to SPEED Hi Lo along the E row of options Step 3 Press the pushbutton to toggle Speed profile between High Low The status LED will change from red to green indicating that the High Speed Profile has been activated or it will change to red indicating that the Low Speed Profile has been activated FIGURE 68 FIGURE 70 Step 4 Return the...

Страница 35: ...atus LED will change from red to green indicating that the High Sensitivity Profile has been activated or it will change to red indicating that the Low Sensitivity Profile has been activated FIGURE 71 Step 4 Return the Function Dial to the RUN position FIGURE 73 K Verifying your setup Should you wish to verify your settings you can rotate the Function Dial to the function that you want to check th...

Страница 36: ...ximum L Reverting to factory defaults It is possible to clear and default the system completely resetting all programmed settings to default values and clearing all learned remotes as well as gate limits To perform a complete reset Remove power from the unit by disconnecting both the mains supply and one battery terminal Press and hold the pushbutton Re apply power to the unit it makes no differen...

Страница 37: ...n be used to charge the battery instead of the conventional charging circuit A 20W panel will provide enough power for 20 daily operations less if 12V DC security lights are fitted of an average gate You will need to fit a deep cycle low maintenance battery minimum 35Ah in order to provide sufficient backup capacity during days of poor weather page 33 These are typical values for Southern Africa C...

Страница 38: ...sure that the rack is properly secured to the gate and that it does not press down onto the operator pinion at any point along its travel Keep shrubs and vegetation clear of the motor and rack Check that the key still operates the camlock spray with lubrication if necessary Keep the inside of the motor housing clear of insects and dust Battery CentSys motors are fitted with high quality maintenanc...

Страница 39: ...kout Mode has been enabled when triggering to operate the gate the gate will not operate but the buzzer will emit one beep periodically for 30 seconds Input voltage failure If the power supply to the charger has failed the buzzer will emit two beeps every two seconds for 30 seconds Photocell s broken If something is in the path of the photocells the buzzer will emit one beep periodically for 30 se...

Страница 40: ...perage output dependant on PSU input voltage Motor voltage Motor power supply Battery charger Current consumption motor at rated load Motor push force starting Motor push force rated Gate mass maximum Gate length maximum Gate speed varies with load Manual Override Life expectancy of electric motor Collision sensing Operating temperature range Onboard receiver type Receiver code storage capacity Re...

Страница 41: ...with your installer about their workmanship warranty terms and conditions For equipment not of CentSys manufacture the warranty as supplied by the original manufacturer will apply No claims whatsoever will be recognised under the terms of this warranty which pertain to damage injury cost or expense suffered by persons and or to property which either directly or indirectly arise out of any one of t...

Страница 42: ...onth Product Warranty D2 Turbo 24 Month Warranty Sticker For your own record and reference purposes if claiming against the warranty stick Barcode product and serial number label for the motor below page 38 ...

Страница 43: ...ne intercom system Allow visitors to communicate with residents in order to gain access to the property FLUX inductive loop detector Allows free exit of vehicles from the property requires ground loop to be fitted Plug in step down transformer The perfect power solution for your D2 Turbo Low Voltage GSM devices Cellular network based devices helping you to control and monitor your world from just ...

Страница 44: ...tallable steel cage that increases the resistance of the operator against theft Theft resistant Nut with Discus padlock Retro installable Theft resistant Nut and padlock set page 40 FIGURE 78 Theft resistant cage Discus padlock Theft resistant Nut ...

Страница 45: ......

Страница 46: ...Ltd South Africa Head Office 27 11 699 2400 Call Technical Support 27 11 699 2481 from 07h00 to 18h00 GMT 2 www CentSys com au Subscribe to the newsletter www CentSys com Subscribe askCentSys facebook com CenturionSystems YouTube com CenturionSystems ...

Отзывы: