Calibrating the TF Plate Professional
Determine the starting position for the laying of the first
module (zero point). Then determine the individual posi-
tions of the screws and butyl sealing strips.
Place the screws into the carrier plate so that they corre-
spond to the dashed line of the image. The distance to the
top and bottom edge is 13 mm (A and C). The center row
(B) is centered between the two laminates. This leads to a
distance of 421 mm to the outer rows.
Fig. 7
Transfer the markings for the fastening points and the out-
er distances onto the trapezoidal metal sheet to determine
the position of the butyl sealing strips.
Fig. 8
Accurate sealing with butyl sealing strips.
To guarantee optimum tightness, the butyl sealing strips
must be cut to 50 mm x 50 mm and bonded to the trap-
ezoidal metal sheet at all screwing positions (Figure 9). If
the TF Plate Professional is laid with adjoining long sides,
the joint area of the two modules must be sealed with a
butyl sealing strip with the following dimensions: 100 mm x
50 mm. This will seal the opposing screwing points.
Fig. 9
Individual Laying
With individual laying the butyl sealing strips must be put
in such a way that they are centered between the screwing
positions. However, they must not project over the edge of
the module (Figure 10).
Fig. 10
In case the high beading distance is particularly small and
the screwing points of the mounting brackets (a) for the
cable duct would therefore be on a high beading, place an
additional butyl sealing strip (b) onto the trapezoidal metal
sheet at this position (Figure 11).
PV module
Butyl strips
Trapezoidal sheet
Zero point
A
C
B
Zero point
B
A
C
13
13
421
421
max. 688 mm
Zero point
A
B
C