Technical instructions Cm Pelet-set 

 

 

6.2. Symbol description 

 

 

Indication of operation of the sanitary water heating pump. 

 

Indication of operation of the heating pump circuit. 

 

Indication of turn on status of timer (time programmes). 

 

Indication of operation of pellet feeding screw feeder. 

 

Indication of flame presence in the burner. 

 

Indication of operation of the burner fan. 

 

Indication of operation of electric heater (for firing of pellets). 

 

An indication of activation errors except errors of safety pressure switch. 

 

Indication  of  the  safety  pressure  switch  due  to  too  high  pressure  in  the  boiler 
combustion chamber. 

 
6.3. Starting display and sanitary water temperature 

 

 

Switching on the control unit  
 

By switching on the control unit via the 
main  switch,  the  control  is  in  OFF 
mode,  i.e.  the  burner  does  not 
operate. 
OFF is displayed in the upper display, 
and 

current 

time 

and 

current 

temperature in the boiler are written 
in the lower display. 

 

 

Indication  of  the  current  sanitary 
water temperature 

 
If  the  sanitary  water  sensor  is 
connected to the control unit and Pr02 
is set to ON, by pressing and keeping 
pressed  +  button, 

in  any  operation 

mode  or  stand-by  mode

,  the  current 

temperature  of  sanitary  water  is 
displayed on lower display. 

6.4. Setting of the burner operating parameters 

 

Setting of the burner operating parameters

 can 

be  done  in  any  operating  mode  (ON  mode)  or 
stand-by (OFF mode) of the burner. 
By  longer  pressing  of  SET  button  the  parameter 
setting  menu  is  entered,  and  by  short  pressing  of 
SET button you can switch from menu to menu. 
Exit  from  a  menu  to  home  display  and  saving  of 
modified  values  is  made  by  short  pressing  of 
On/Off  button  or  by  passing  through  all  8 
parameters and returning to the home display. 
If no button is pressed for 90 seconds, the control 
unit  exits  from  a  menu  to  home  display  without 
saving of modified parameters. 

Содержание EKO-CK 20

Страница 1: ...NERGETSKIH URE AJA 40306 MACINEC GLAVNA 12 HRVATSKA tel 040 372 600 fax 040 372 611 TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet set 14 35 kW For boilers EKO CK P 20 40 EKO CK 20 40 EKO CKB P 2...

Страница 2: ...rst firing 7 2 Extinction procedure 8 Control unit operation 8 1 Firing phase 8 2 Transition phase 8 3 Operation phase 8 4 Extinction phase 8 5 Operation with timer 8 6 Anti frost protection programme...

Страница 3: ...llets when required A built in photo cell serves for flame detection in the burner Special shape of a combustion chamber enables good mixing of air and fuel which gives high efficiency of combustion C...

Страница 4: ...fore filling of the tank it is necessary to open the lid on the tank top and check whether the tank is free from solid objects or any other foreign objects which should not be there Assembly of the pe...

Страница 5: ...urner shut down and the error E1 is displayed at control unit LED diode switched on If lower boiler door are opened while the burner is working micro switch on lower boiler door cuts the el power to t...

Страница 6: ...on Button function Safety thermostat button 0 1 Main switch to turn on turn off power supply to the control unit Start stop button on Off By pressing the button for 3 sec the burner turns on While the...

Страница 7: ...ed in the upper display and current time and current temperature in the boiler are written in the lower display Indication of the current sanitary water temperature If the sanitary water sensor is con...

Страница 8: ...Pr02 to ON and by pressing SET button we enter sub programme Pr02 Sub programme Pr02 Sanitary water set temperature Factory setting 50 C Available setting min 40 C max 80 C If is inbuilt sanitary wat...

Страница 9: ...xample if we wish to turn inactivating time for Mondays we have to change DAY1 OFF by or buttons to DAY1 ON and then press SET button Sub programme Pr05 Setting 1 st activating time I On refers to the...

Страница 10: ...pressing button and room thermostat is obligatory set to minimum control unit will monitor temperature in the boiler and sanitary water tank and when it drops below 5 0 C the burner will turn on and h...

Страница 11: ...rently set programme are displayed in the lower display and after that both displays resume their original settings OFF is displayed in the upper display and current time boiler temperature are displa...

Страница 12: ...in the lower display 15 When the burner reaches set output after approx 8 to 15 minutes depending on set power and after the flame is stabilised flue gases have to be analysed and if necessary to per...

Страница 13: ...t reach temperature Tset within 2 minutes the burner resumes to set output and at temperature Tset the burner the burner starts extinction procedure The burner re ignites when the boiler temperature d...

Страница 14: ...rner operation minimum burner work time is 1 hour and min stand by time between two activating times is 1 minute 8 6 Frost protection programme allowed to use only if the room thermostat is connected...

Страница 15: ...me Err will be displayed in the upper display and E230 will be displayed in the lower display indicating that error could be caused by power supply interruption If the main switch turns off or power s...

Страница 16: ...eeding tube LED diode turns on E4 boiler temperature sensor E5 sanitary water temperature sensor E6 flame disappeared E7 error in memory E8 interruption in fan operation E9 backfilling supply tube wit...

Страница 17: ...Photocell does not detect flame in the burner combustion chamber Due to lack of pellets feeding of too moist pellets or due to dirty photocell E7 error in memory Memory failure Resetting of control u...

Страница 18: ...each consumed pellet tank approx 200 kg If required cleaning frequency can be increased or reduced compared to the recommended one depending on quality of pellets and frequency of the burner turning o...

Страница 19: ...onnectors for electrical connections built in below burner cover which power lines in safety rail to connectors are coming from burner bottom see schemes in this manuals not the through cover side of...

Страница 20: ...t be responsible for possible incorrect data caused by printing errors or errors during transcription and in any case it reserves the right to modify its products deemed to be required and useful with...

Отзывы: