Technical instructions Cm Pelet-set 

 

 

1. Introduction 
 
Cm  Pelet-set,

  wood  pellet  based  heating  system  (nominal  burner  output  of 

14  kW

  and  from 

20 

to     

35  kW)

  designed  for  installation  in  combined  boilers  or  biomass  firing  boilers 

EKO-CK  P  (EKO-CK) 

and 

EKO-CKB  P  (EKO-CKB), 

  with  thermal  output  from  20  to  40  kW.  These  technical  instructions 

provide  basic  product  information,  its  technical  characteristics  and  instructions  on  use  and 
maintenance  of  its  components.  Cm  Pelet-set  components  are  of  modern  design  and  construction, 
made  of  high  quality  materials  having  all  required  certificates.  Cm  Pelet-set  installation  and  start-up 
must be carried out by a professional or authorized fitter of manufacturer. 
Instructions  for  fitters/servicemen  presenting  setting  of  all  parameters  of  pellet  regulation  are  also 
supplied with these instructions. 
 
 

2. Status at delivery

 

 

1.  Pellet burner CPPL-14 or CPPL-35 
2.a.) Set for installation of pellet burner (only new boiler models) 
2.b) Lower boiler door CPDV (only for models that have special doors for installation of pellet   
       burner) 
3.  Boiler control unit CPREG 
4.  Pellet feeder CPPT 
5.  Pellet tank CPSP 

 

2.1 Pellet burner CPPL 

 
Pellet - burner 

CPPL 14

 (nominal thermal output of 14 kW, for boiler EKO-CK P 20 (EKO-CK 20) and 

EKO-CKB  P  20  (EKO-CKB  20))  and 

CPPL-35

  (nominal  thermal  output  of  20  to  35  kW,  for  boilers 

EKO-CK  P  25-40  (EKO-CK  25-40),  EKO-CKB  P  25-40  (EKO-CKB  25-40))  consists  of  high  quality 
components and made of certified built-in materials. The burner includes high-efficiency fan which, by 
aid of specially shaped burner grate creates a flame as in standard burners. The burner also includes 
electrical  heater  which,  via  the  control  unit,  automatically  ignites  pellets  when  required.  A  built-in 
photo-cell  serves  for flame  detection  in  the  burner.  Special  shape  of  a  combustion  chamber  enables 
good mixing of air and fuel which gives high efficiency of combustion. CPPL-14 burner has additional 
ceramic  nozzle  which  improves  fuel  combustion.  Depending  on  the  operating  phase  and  set  output, 
fan  revolution  number,  i.e.  air  supply  to  the  chamber  is  changed.  The  burner  is  designed  for 
installation  into  prepared  openings  at the  lower  boiler  door  CPDV.  The  burner  is  factory  wired  and  it 
has to be connected to the boiler control unit CPREG. 
 

2.a)

 

Set for installation of pellet burner (only new boiler models)  

 
At the current lower boiler door is necessary to upgrade the bracket for pellet burner installation. 

 

2.b) Lower boiler door 

 
Lower  boiler  door 

CPDV

  with  an  opening  adapted  for  pellet  burner  is  supplied  with  the  pellet burner 

CPPL (except in case of supply of a boiler with Cm Pelet-set, when the lower boiler door CPDV is pre-
installed  onto boiler).  Standard  boiler  door  has  to be  dismantled  from  the  boiler  instead  of  which  the 
supplied boiler door CPDV is installed onto which the pellet burner is assembled. 
 

2.3 Boiler control unit CPREG 

 
Sophisticated  digital  boiler  control  unit 

CPREG

  controls  the  burner  in  accordance  with  the  need  for 

heating and sanitary  water. Characteristics of the boiler control  unit CPREG: microprocessor control, 
bimetal safety thermostat, safety pressure switch, micro switch for lower boiler door, control unit turns 
on and off the burner according to set temperatures and operation regimes, regulates pellet supply by 
the feeder, operation in  winter or summer regime, boiler protection against condensation, display the 
boiler  current  status  on  the  screen,  error  messages  on  the  screen,  with  boiler  sensor  and  sanitary 
water  sensor  supplied.  Operation  and  setting  of  individual  parameters  are  described  in  details 
hereinafter. 

Содержание EKO-CK 20

Страница 1: ...NERGETSKIH URE AJA 40306 MACINEC GLAVNA 12 HRVATSKA tel 040 372 600 fax 040 372 611 TECHNICAL INSTRUCTIONS USE AND MAINTENANCE Cm Pelet set 14 35 kW For boilers EKO CK P 20 40 EKO CK 20 40 EKO CKB P 2...

Страница 2: ...rst firing 7 2 Extinction procedure 8 Control unit operation 8 1 Firing phase 8 2 Transition phase 8 3 Operation phase 8 4 Extinction phase 8 5 Operation with timer 8 6 Anti frost protection programme...

Страница 3: ...llets when required A built in photo cell serves for flame detection in the burner Special shape of a combustion chamber enables good mixing of air and fuel which gives high efficiency of combustion C...

Страница 4: ...fore filling of the tank it is necessary to open the lid on the tank top and check whether the tank is free from solid objects or any other foreign objects which should not be there Assembly of the pe...

Страница 5: ...urner shut down and the error E1 is displayed at control unit LED diode switched on If lower boiler door are opened while the burner is working micro switch on lower boiler door cuts the el power to t...

Страница 6: ...on Button function Safety thermostat button 0 1 Main switch to turn on turn off power supply to the control unit Start stop button on Off By pressing the button for 3 sec the burner turns on While the...

Страница 7: ...ed in the upper display and current time and current temperature in the boiler are written in the lower display Indication of the current sanitary water temperature If the sanitary water sensor is con...

Страница 8: ...Pr02 to ON and by pressing SET button we enter sub programme Pr02 Sub programme Pr02 Sanitary water set temperature Factory setting 50 C Available setting min 40 C max 80 C If is inbuilt sanitary wat...

Страница 9: ...xample if we wish to turn inactivating time for Mondays we have to change DAY1 OFF by or buttons to DAY1 ON and then press SET button Sub programme Pr05 Setting 1 st activating time I On refers to the...

Страница 10: ...pressing button and room thermostat is obligatory set to minimum control unit will monitor temperature in the boiler and sanitary water tank and when it drops below 5 0 C the burner will turn on and h...

Страница 11: ...rently set programme are displayed in the lower display and after that both displays resume their original settings OFF is displayed in the upper display and current time boiler temperature are displa...

Страница 12: ...in the lower display 15 When the burner reaches set output after approx 8 to 15 minutes depending on set power and after the flame is stabilised flue gases have to be analysed and if necessary to per...

Страница 13: ...t reach temperature Tset within 2 minutes the burner resumes to set output and at temperature Tset the burner the burner starts extinction procedure The burner re ignites when the boiler temperature d...

Страница 14: ...rner operation minimum burner work time is 1 hour and min stand by time between two activating times is 1 minute 8 6 Frost protection programme allowed to use only if the room thermostat is connected...

Страница 15: ...me Err will be displayed in the upper display and E230 will be displayed in the lower display indicating that error could be caused by power supply interruption If the main switch turns off or power s...

Страница 16: ...eeding tube LED diode turns on E4 boiler temperature sensor E5 sanitary water temperature sensor E6 flame disappeared E7 error in memory E8 interruption in fan operation E9 backfilling supply tube wit...

Страница 17: ...Photocell does not detect flame in the burner combustion chamber Due to lack of pellets feeding of too moist pellets or due to dirty photocell E7 error in memory Memory failure Resetting of control u...

Страница 18: ...each consumed pellet tank approx 200 kg If required cleaning frequency can be increased or reduced compared to the recommended one depending on quality of pellets and frequency of the burner turning o...

Страница 19: ...onnectors for electrical connections built in below burner cover which power lines in safety rail to connectors are coming from burner bottom see schemes in this manuals not the through cover side of...

Страница 20: ...t be responsible for possible incorrect data caused by printing errors or errors during transcription and in any case it reserves the right to modify its products deemed to be required and useful with...

Отзывы: