Maintenance and cleaning

The thermostove requires a simple and thorough cleaning 
in order to ensure a more efficient performance and 
smooth operation.
While cleaning the inside of the thermostove, to prevent 
the escape of ashes, you can start the fan flue exhaust. 
To enable this feature, you must press the button 

 and 

then  .
The  display  shows  “

P U L   S T U F

”  (cleaning  thermostove). 

To stop the fan, simply press and hold the button   or wait 
for completion of a cleaning cycle (255 seconds).
Clean  the  grate  using  the  appropriate  tool  from  the  ash 
and  any  incrustation  which  could  obstruct  the  passage 
of air. In the case of depletion of pellets in the tank may 
accumulate unburned pellets in the burn pot.
Always  empty  the  residuals  from  the  grate  before  each 
start.  Remember  that  only  a  brazier  located  and  clean 
properly can ensure ignition and optimal operation of your 
thermostove.  When  positioning  the  crucible,  carefully 
check  that  the  ends  of  the  pads  completely  adhere  to 
their home and that the hole with pipe dedicated to the 
passage of the resistance.
There  should  be  no  residual  combustion  in  the  contact 
zone between the edges of the crucible and the support 
surface on the door crucible.

Parts

Everyday

Every 2-3 

days

Every 

week

Every 15 

days

Every 30 

days

Every 60-

90 days

Every 1 

year

Brazier

Cleaning the ash collection 
compartment with suction device

Cleaning ash tray

Cleaning the door and glass

Exchanger (turbulators)

Cleaning the interior heat exchanger /
smoke fan compartment

Cleaning complete exchanger

Clean "T" to exhaust

Flue

Door gasket ash

Internal parts

Flue pipe

Circulation pump

Plate heat exchanger

Hydraulic components

Electromechanical components

◊ by the user

by the authorised qualified technical assistance

BY ThE USER

Daily control

All cleaning of all parts must be carried out with the stove completely cold and unplugged to 
avoid burns and thermal shock. The stove does not need much maintenance if used with certified 
quality pellet. The need for maintenance varies depending on the conditions of use (switching on 
and off repeatedly) and depending on the performance required.

The decreased or absent cleaning can 
cause misfire and cause damage to the 
thermostove and the environment (possi-

ble emissions of soot and unburned). Do not pour 
the pellets may be present in the brazier to misfire.

Содержание CentroPelet ZV 20

Страница 1: ...QUE CentroPelet ZV 20 24 32 TURZV 08 2014 HR Centrometal d o o Glavna 12 40306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TECHNICAL INSTRUCTIONS for installation use and maintenance of pell...

Страница 2: ...Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly must be performed by authorized persons Authorized Assist...

Страница 3: ...ivil and penal for accidents deriving from the partial or total lack of observance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from inc...

Страница 4: ...y clothes hangers and suchlike must be kept a suitable distance from the stove Risk of fire Carefully explain that the thermostove is made from ma terial subjected to high temperatures for the elderly...

Страница 5: ...able maintain a minimum distance of 10 cm at the rear A di 40 cm at the side B and 150 cm at the front If the room contains objects which are believed to be particularly delicate such as drapes sofas...

Страница 6: ...less steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue pi...

Страница 7: ...st be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself Fig 5 Characteristics of...

Страница 8: ...s a lever to lift the cover Replace the battery observing the correct polarity Fig 4 Size 12V Fig 3 Fig 4 Size 12V Technical Specification Remote Control N B measures with a tolerance of about 10 mm 1...

Страница 9: ...to 1 The LED is on when the parameter UT01 on the menu is not on OFF and the weekly or daily programming are set SET LED SYMBOL DESCRIPTION The LED starts up every time the stove is loading pellets T...

Страница 10: ...To set the water temperature press the key only once You will see the words Set H2o blinking on the upper display You will read the water temperature on the lower display To set the room temperature p...

Страница 11: ...control panel for example 18 C and a sufficient shut down time has elapsed the thermostove will come back on automatically and continue running until again reaching 20 C Regardless of the operation o...

Страница 12: ...ety and can make it back in the system through the inlet pipe causing a phenomenon of oxygen that is highly damaging to life of the boiler To prevent this phenomenon it is possible to apply the follow...

Страница 13: ...en it requires routine and or special maintenance Connect the stove using hoses so that the stove is not too strictly connected to the system and to allow slighht movement The filling pressure of the...

Страница 14: ...ormation of incrustations along the pipes in the boiler and in the heat exchangers Therefore please get your plumber s advice concering Hardness of water circulating in the system to prevent problems...

Страница 15: ...Friday Day 6 Saturday Day 7 Sunday OFF Heating timer thermostat disabled UT07 Week day selection Press button o select the days of the week Press button to enable ON or disable OFF the pellet boiler s...

Страница 16: ...er fuses to protect the electronic boards are to be found on the boards themselves Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel an...

Страница 17: ...sensor Check the water sensor is connected Contact an Authorized Assistance Center ALAR ALAR ALAR ALAR ALAR ALAR COOL ALAR ALAR ALAR ALAR SERV Hot temp The smokes temperature exceeds 280 C Smokes sens...

Страница 18: ...he tank or because the motor reducer for pellets loading got broken The thermostove continues working until the pellets left in the brazier ends You will then read the words Alar No Fire on the displa...

Страница 19: ...ould be no residual combustion in the contact zone between the edges of the crucible and the support surface on the door crucible Parts Everyday Every 2 3 days Every week Every 15 days Every 30 days E...

Страница 20: ...tion Check every 60 90 days Cleaning the interior baffle smoke fan compartment Inside the compartment where there is the ash tray there is a second cover fixed by the cockerels which gives access to t...

Страница 21: ...e there is a fuse holding compartment which is located underneath the supply socket With a screwdriver open the cover of the fuse holding compartment and replace the fuse if necessary 3 15 AT delayed...

Страница 22: ...icular Do not touch the thermostove body and the various components do not approach the door it could cause burns Do not touch the exhaust fumes Do not perform any type of cleaning Do not dump the ash...

Страница 23: ...r non original The operations marked in bold type must be carried out by specialised personnel Any kind of tampering or unauthorized substitution of non original of the thermostove can be hazardous to...

Страница 24: ...not closed properly or gaskets worn 5 Boiler temperature is too high 6 Unsuitable pellets 7 Low pellet feed rate 8 Combustion chamber dirty 9 Smoke outlet obstructed 10 Smoke extraction motor failed...

Страница 25: ...fan convention never stops 1 Temperature sensor temperature control defective or broken 2 Fan failure 1 Check operation of the sensor and replace if necessary 2 Check operation of the motor and repla...

Страница 26: ...gh 2 It was set too much power to the implant 1 Lower the temperature in the boiler 2 Reduce the value of operating power The thermostove goes into modulation as it reaches the temperature set on the...

Страница 27: ...GB...

Страница 28: ...2 fax 385 40 372 621 Centrometal d o o shall not be responsible for possible incorrect data caused by printing errors or error made in transcription and all figures and diagrams are for explanatory pu...

Отзывы: